GENERAL NOTES: 64. ALL REMOTE-CONTROL,SIGNALING,AND POWER-LIMITED CIRCUITS SHALL COMPLY WITH NEC ARTICLE 725.
<br /> 1. THE DESIGN DRAWINGS AND DOCUMENTS APPROVED UNDER THIS MATERIALS AND METHODS APPLICATION SHALL ONLY APPLY TO SINGLE-FAMILY DWELLINGS. 65. ALL NEW/MODIFIED 120V,SINGLE-PHASE,15 AND 20 AMPERE BRANCH CIRCUITS INSTALLED INA DWELLING(EXCEPT IN BATHROOMS AND GARAGES)SHALL HAVE
<br /> 2. THE ELECTRICAL CONTRACTOR SHALL NOT DEVIATE IN ANY WAY FROM THE APPROVED DESIGN DRAWINGS AND DOCUMENTS. ARC-FAULT CIRCUIT INTERRUPTER PROTECTION IN ACCORDANCE WITH NEC SECTIONS 210.12(A)AND 210.12(D).
<br /> 3. THE SCOPE OF WORK SHOWN IN THE APPROVED DESIGN AND DOCUMENTS SHALL BE DONE IN THE ENTIRETY,PARTIAL INSTALLATIONS ARE PROHIBITED. BLUE
<br /> RAVEN`7I
<br /> 4. THE EXISTING CONDITIONS SPECIFIED IN THE DESIGN DRAWINGS AND DOCUMENTS SHALL NOT DEVIATE FROM THE ACTUAL SITE CONDITIONS. SYSTEM INSTALLATION NOTES: BLUE inti VL-+N
<br /> 5. THE BATTERY AREA SHALL BE COMPLIANT WITH NEC SECTION 110.26(D)OR 210.70(A)(3),IF APPLICABLE. 1. WALL CONSTRUCTION SHALL BE CAPABLE OF ACCOMMODATING ALL LOADS IMPOSED ACCORDING TO SECTION R301 AND OF TRANSMITTING THE RESULTING LOADS TO SOLAR
<br /> 6. PHYSICAL PROTECTION SHALL BE PROVIDED FOR THE NEW ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC SECTION 110.27(B)OR 110.26(E)(2)(a),IF APPLICABLE. THE SUPPORTING STRUCTURAL ELEMENTS.REF 2012 IRC,SECTION R601.2.
<br /> 7. THE CHEMISTRY OF THE BATTERY IS SUCH THAT VENTILATION PER NEC SECTION 480.10(A)AND 706.10(A)IS NOT REQUIRED. 2. COMPLY WITH 2012 IRC,SECTION R317.3,RATED PENETRATIONS.PENETRATIONS OF WALL OR FLOOR/CEILING ASSEMBLIES REQUIRED TO BE FIRE-RESISTANT RATED IN
<br /> 8. ADEQUATE WORKING SPACE WILL BE PROVIDED ABOUT THE BATTERY EQUIPMENT PER NEC SECTION 480.10(C)AND/OR NEC SECTION 706.10(C). ACCORDANCE WITH SECTION R317.1 OR R317.2 SHALL BE PROTECTED IN ACCORDANCE WITH THIS SECTION.
<br /> 9. INSTALLATION SHALL BE IN COMPLIANCE WITH NEC SECTION 110.26. 1403 N 630 E
<br /> 10. ALL ELECTRICAL WORK WILL COMPLY WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS,NEC SECTION 110.3(B)AND THE REVISED ORDINANCES OF HONOLULU SYSTEM OPERATIONAL NOTES: Ore ril,Utah 84097
<br /> CHAPTER 17. 1. DURING THE DAY,THE FRANKLINWH HOME POWER SOLUTION WILL PRIORITIZE FEEDING HOUSE LOADS AND CHARGE BATTERIES SECONDARILY.
<br /> 11. INSTALLATION SHALL BE IN COMPLIANCE WITH NEC SECTIONS 240.24(A)AND 404.8(A). 2. DURING THE EVENING,THE FRANKLINWH HOME POWER SOLUTION WILL BE PROGRAMMED TO PROVIDE POWER TO HOUSE LOADS.THE FRANKLINWH HOME POWER (800)377-4480
<br /> 12. THE EXISTING SERVICE EQUIPMENT CAN HANDLE THE ADDITIONAL BATTERY CHARGING LOADS AND THE CONTRACTOR SHALL PROVIDE A SERVICE LOAD CALCULATION SOLUTION MAY BE PROGRAMMED TO SUPPLY POWER TO THE GRID IN ACCORDANCE WITH THE UTILITY DER PROGRAM. Blue Ra V e n SO la rx O m
<br /> TO 3. UNDER NORMAL UTILITY OPERATION,LOADS CONNECTED TO THE NON-BACKUP TERMINALS WILL UTILIZE POWER FROM THE ENERGY SOURCES IN THE FOLLOWING
<br /> THE ELECTRICAL INSPECTOR UPON REQUEST. PRIORITIES:1)PV SYSTEM,2)BATTERY(PROVIDED BATTERY HAS REACHED MINIMUM SOC VALUE),3)GRID.DURING UTILITY OUTAGE,LOADS CONNECTED TO THE
<br /> 13. THE OVERCURRENT DEVICE/DISCONNECT OF THE BATTERY WILL BE WITHIN 5 FEET OF THE BATTERY AND NOT BE SEPARATED FROM THE BATTERY BY A WALL OR NON-BACKUP TERMINALS WILL NOT HAVE POWER.
<br /> PARTITION 4. UNDER NORMAL UTILITY OPERATION,LOADS CONNECTED TO THE BACKUP TERMINALS WILL UTILIZE POWER FROM THE THREE ENERGY SOURCES IN THE FOLLOWING
<br /> IN ACCORDANCE WITH NEC SECTION 706.7(E). PRIORITIES:1)PV SYSTEM,2)BATTERY(PROVIDED BATTERY HAS REACHED MINIMUM SOC VALUE),3)GRID.DURING UTILITY OUTAGE,LOADS CONNECTED TO THE BACKUP REVISIONS
<br /> 14. THE PROJECT WILL NOT INCLUDE GROUND DISTURBANCE AND WILL NOT BE LOCATED INA FLOOD HAZARD. TERMINALS WILL UTILIZE POWER FROM THE ENERGY SOURCES IN THE FOLLOWING PRIORITIES:1)PV SYSTEM,2)BATTERY(PROVIDED BATTERY HAS REACHED MINIMUM
<br /> 15. ALL PENETRATIONS MADE TO ANY FIRE-RESISTANT-RATED WALLS,PARTITIONS,FLOORS,OR CEILINGS SHALL BE CORRECTED TO MAINTAIN THE FIRE RESISTANCE RATING SOC VALUE). Description Late Rev
<br /> IN 5. THE FRANKLINWH HPS CAN OPERATE WITHOUT A CONNECTED PV SYSTEM.IN THIS CONFIGURATION THE BATTERIES WILL BE CHARGED FROM THE GRID ACCORDING TO hirdalDesign 2/9/2024 00
<br /> ACCORDANCE WITH NEC SECTIONS 300.21,725.3(B),AND 800.26,IF APPLICABLE. THE PROGRAMED TIME OF USE SCHEDULE.
<br /> 16. PVC CONDUIT SHALL BE INSTALLED IN ACCORDANCE WITH NEC SECTION 352.10 AND SHALL NOT BE INSTALLED UNDER THE CONDITIONS DESCRIBED IN NEC SECTION 6. IF PV PRODUCTION EXCEEDS THE LOAD CONSUMPTION IN THE PANEL CONNECTED TO THE BACKUP TERMINALS WHEN THE BATTERIES ARE FULLY CHARGED,aGATE WILL
<br /> 352.12. EITHER LIMIT PRODUCTION OR PERMIT EXCESS PV TO BE EXPORTED TO THE UTILITY IN ACCORDANCE WITH THE UTILITY DER PROGRAM.
<br /> 17. THE PV AND BATTERY ENERGY STORAGE SYSTEMS WILL OPERATE AS STANDALONE SYSTEMS DURING UTILITY OUTAGE.THE PV AND BATTERY ENERGY STORAGE 7. IF HOUSE LOAD CONSUMPTION EXCEEDS PV PRODUCTION(DURING THE DAY)THE UTILITY WILL SUPPLEMENT THE REMAINING POWER.WHEN THE UTILITY GOES OFFLINE
<br /> SYSTEMS THE aGATE UNIT HAS AN INTERNAL AUTOMATIC TRANSFER SWITCH(ATS)THAT SWITCHES THE PANEL CONNECTED TO THE BACKUP LOAD TERMINALS OVER TO BATTERIES
<br /> WILL COMPLY WITH THE PROVISIONS OF NEC ARTICLE 710. WITHIN 16MS.WHEN THE UTILITY POWER IS RESTORED THE aGATE WILL SWITCH ATS TO NORMAL POSITION AND OPERATION UNDER NORMAL CONDITION DESCRIBED ABOVE
<br /> 18. ALL EMT CONDUIT SHALL BE INSTALLED IN ACCORDANCE WITH NEC SECTION 358.10 AND SHALL NOT BE INSTALLED UNDER THE CONDITIONS DESCRIBED IN NEC SECTION WILL RESUME. Signature with Seal
<br /> 358.12 8. WHEN A UTILITY OUTAGE OCCURS DURING THE DAY AND EVENING,LOADS IN THE PANEL CONNECTED TO THE BACKUP LOAD TERMINALS WILL BE OPERATIONAL BASED
<br /> 19. EMT AND PVC CONDUIT WILL BE SIZED IN ACCORDANCE WITH NEC SECTION 358.22 OR 352.22,RESPECTIVELY. ON AMOUNT OF ENERGY STORED IN BATTERY..
<br /> 20. UNGROUNDED CONDUCTORS SHALL COMPLY WITH NEC SECTION 240.4 AND EQUIPMENT GROUNDING CONDUCTORS SHALL COMPLY WITH NEC SECTION 250.122. 9. THE CONDITIONS UNDER WHICH THE BATTERIES WILL BE CHARGED AND DISCHARGED ARE SECOND PRIORITY TO LOADS IN THE PANEL CONNECTED TO THE BACKUP
<br /> 21. THE SERVICE DISCONNECTS SHALL COMPLY WITH NEC SECTION 230.70,230.71,AND 230.72. TERMINALS DURING THE DAY.ENERGY SOURCES FOR BATTERY CHARGING ARE SELECTABLE AND INCLUDE UTILITY WHEN AVAILABLE,AND PV WHEN PRODUCTION EXCEEDS
<br /> 22. THE EXISTING DWELLING PANELBOARD SHALL COMPLY WITH NEC SECTIONS 408.30 AND 408.36. THE CONSUMPTION OF BACKUP LOADS.AC-COUPLED BATTERIES ARE CHARGED VIA aGATE UNIT.
<br /> 23. ALL NEW EQUIPMENT SHOULD BE LOCATED ON THE SAME STRUCTURE AS THE EXISTING SERVICE EQUIPMENT(I.E.THERE WILL BE NO OUTSIDE FEEDER OR BRANCH 10. THE aGATE UNIT WILL CUTOFF THE BATTERY SYSTEM WHEN IT REACHES MAXIMUM DEPTH OF DISCHARGE(DOD)OR WHEN PROGRAMMED SCHEDULE TIME LIMITS ARE
<br /> CIRCUITS) MET DURING NORMAL UTILITY AVAILABILITY.DURING UTILITY OUTAGE THERE IS NO SCHEDULE AND THE AC-COUPLED BATTERY WILL PROVIDE POWER UNTIL REACHING DOD,
<br /> 24. THE INSTALLATION WILL COMPLY WITH THE 2017 NATIONAL ELECTRICAL CODE AND ALL CODES AND ORDINANCES OF THE CITY AND COUNTY OF HONOLULU. VIA aGATE UNIT.aGATE SHALL BE CONFIGURED TO ALLOW AC POWER FROM THE BATTERY ENERGY STORAGE SYSTEM ONTO THE UTILITY GRID IN ACCORDANCE WITH
<br /> 25. FURNISH ALL CONDUITS,RACEWAYS,CONDUCTORS,DISCONNECTS,COMBINER BOXES,PULL BOXES,HANDHOLES,JUNCTION BOXES,DEVICES,AND OTHER MATERIALS CUSTOMER DER AGREEMENT.
<br /> NECESSARY FOR COMPLETE OPERATIONAL ELECTRICAL SYSTEMS..
<br /> 26. NO CIRCUIT MAY EXCEED 75 FEET OF CONDUCTOR LENGTH WITHOUT INCREASE OF WIRE SIZE. BATTERY INSTALLATION NOTES:
<br /> 27. ELECTRICAL CONTRACTOR SHALL NOTE ANY EXISTING ELECTRICAL CODE ISSUES AND REPORT THEM TO THE OWNER AND THE ELECTRICAL ENGINEER. 1. INSTALL BATTERY SYSTEM WITH WORKING SPACE IN ACCORDANCE WITH NEC SECTIONS 480.10(C),110.26 AND 706.10(C).
<br /> 28. PROPER KAIC BREAKERS,FUSES,AND EQUIPMENT SHALL BE INSTALLED. 2. BATTERIES SHALL BE PROVIDED WITH ADEQUATE ILLUMINATION IN ACCORDANCE WITH NEC SECTIONS 480.10(G)AND 706.10(E)OR A SEPARATE PERMIT WILL BE
<br /> 29. ENERGY SYSTEM POINT OF CONNECTION SHALL MEET THE REQUIREMENT OF NEC SECTION 705.12. OBTAINED PRIOR TO THE INSTALLATION OF THE BATTERIES TO INSTALL NEW LUMINAIRE(S)AT THE BATTERY LOCATION.
<br /> 30. CONDUCTOR LISTING SHALL MATCH THE INTENDED USE. 3. INSTALL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC SECTION 110.26(A)(3).
<br /> 31. NEW DISCONNECTS SHALL BE LOCATED IN ACCORDANCE WITH NEC SEC 230.72. 4. INSTALL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC SECTION 110.11.
<br /> 32. INSTALL ALL EQUIPMENT IN ACCORDANCE WITH NEC ARTICLES 690&705. 5. REFER TO THE FRANKLIN HOME POWER SOLUTION INSTALLATION MANUAL FOR THE INSTALLATION OF BATTERIES.
<br /> 33. PVC SHALL BE SCHEDULE 80 IN AREAS SUBJECT TO PHYSICAL DAMAGE IN ACCORDANCE WITH NEC SECTION 352.10(F).IN ALL OTHER AREAS,PVC SHALL BE SCHEDULE 40. Project Name&
<br /> 34. EQUIPMENT SHALL BE MOUNTED,SUPPORTED,AND ANCHORED FOR 1.0 G SEISMIC RESTRAINT FORCES. INVERTER NOTES: Address
<br /> 35. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL LOCAL AUTHORITIES AND UTILITIES HAVING JURISDICTION PRIOR TO ORDERING EQUIPMENT AND PRIOR TO 1. OCPD FOR INVERTER SHALL BE SUITABLE FOR BACKFEED IN ACCORDANCE WITH NEC SECTION 705.12(B)(4).
<br /> INSTALLATION/LOCATION OF EQUIPMENT. 2. ALL CONDUIT TO BE PVC SCHEDULE 40 EXCEPT AS NOTED IN GENERAL NOTE 33.
<br /> 36. ALL GENERAL CONDUCTORS SHALL BE 90 DEGREE RATED AND WET RATED UNLESS OTHERWISE NOTED.
<br /> 37. ELECTRICAL CONTRACTOR SHALL TAKE THE NECESSARY SAFETY PRECAUTIONS TO ENSURE THAT NO PERSON IS EXPOSED TO DANGEROUS LEVELS OF VOLTAGE OR BATTERY SAFETY NOTES:
<br /> CURRENT 52.1 GENERAL
<br /> WITHOUT THE NECESSARY SAFETY EQUIPMENT AND PROCEDURES IN PLACE. STATIONARY STORAGE BATTERY SYSTEMS HAVING AN ELECTROLYTE CAPACITY OF MORE THAN 100 GAL.(378.5 L)IN SPRINKLERED BUILDINGS OR 50 GAL.(189.3 L)IN
<br /> 38. CONSTRUCTION AREAS SHALL BE SECURED AND PROPER SIGNAGE SHALL BE IN PLACE.OSHA REGULATIONS SHALL BE ADHERED TO. UNSPRINKLERED BUILDINGS FOR FLOODED LEAD-ACID,NICKEL CADMIUM,AND VALVE-REGULATED LEAD-ACID(VRLA)BATTERIES OR 1000 LB(454 KG)FOR LITHIUM-ION AND
<br /> 39. ELECTRICAL CONTRACTOR SHALL VERIFY THAT TRANSFER SWITCH AUTOMATICALLY TRANSFERS POWER WHEN UTILITY POWER IS LOST. LITHIUM-ION AND LITHIUM METAL POLYMER BATTERIES USED FOR FACILITY STANDBY POWER,EMERGENCY POWER,OR UNINTERRUPTED POWER SUPPLIES SHALL BE IN ^
<br /> 40. EQUIPMENT,AC DISCONNECTS,AND INVERTER AC DISCONNECTS SHALL BE LABELED PER LOCAL AHJ AND NEC ARTICLE 690. ACCORDANCE WITH CHAPTER 52 AND TABLE 52.1. a
<br /> 41. MINIMUM BONDING CONDUCTOR IN RACEWAY SHALL BE#8.DRAWING MAY REQUIRE LARGER SIZE.MINIMUM BONDING CONDUCTOR,IF EXPOSED SHALL BE#6 COPPER. 52.3.2 THERMAL RUNAWAY VRLA,LITHIUM-ION AND LITHIUM METAL POLYMER BATTERY SYSTEM SHALL BE PROVIDED WITH A LISTED DEVICE OR OTHER APPROVED METHOD TO <=) N
<br /> 42. ALL WIRE SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. PRECLUDE,DETECT AND CONTROL THERMAL RUNAWAY. r� 00 QQQ
<br /> 43. PROVIDE NYLON PULL CORDS IN ALL EMPTY CONDUIT. LOCATION AND OCCUPANCY SEPARATION LSI / O�
<br /> 44. VERIFY ALL DEVICE FINISHES WITH OWNER. 52.3.3.2 BATTERY SYSTEMS SHALL BE HOUSED IN A NON-COMBUSTIBLE,LOCKED CABINET OR OTHER ENCLOSURE TO PREVENT ACCESS BY UNAUTHORIZED PERSONNEL
<br /> 45. MINIMUM CONDUIT BENDING RADIUS SHALL BE SIX TIMES INTERNAL DIAMETER FOR TRADE SIZE 2 INCHES OR LESS. UNLESS LOCATED IN A SEPARATE O M
<br /> 46. MINIMUM CONDUIT BENDING RADIUS SHALL BE TEN TIMES INTERNAL DIAMETER FOR TRADE SIZE GREATER THAN 2 INCHES. EQUIPMENT ROOM ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL. +
<br /> 47. LABEL ALL WIRE BOXES,AND CONDUIT AS INDICATED ON DRAWINGS. 52.3.3.3 IN OTHER THAN ASSEMBLY,EDUCATIONAL,DETENTION AND CORRECTION FACILITIES,HEALTH CARE,AMBULATORY HEALTH CARE,DAY CARE CENTERS,RESIDENTIAL p 00
<br /> 48. ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE LATEST ADOPTED NATIONAL ELECTRICAL CODE.PENETRATIONS SHALL BE FIRE-STOPPED AND BOARD AND CARE AND RESIDENTIAL <=)
<br /> OPENINGS OCCUPANCIES,BATTERY SYSTEMS SHALL BE LOCATED IN A ROOM SEPARATED FROM OTHER PORTIONS OF THE BUILDING BY A MINIMUM OF A 1 HOUR FIRE BARRIER. M
<br /> SHALL BE PROTECTED THROUGH FIRE-RATED WALLS,FLOOR,ROOF AND CEILING ASSEMBLIES AS REQUIRED BY THE 2012 IBC CHAPTER 7. VENTILATION �p
<br /> 49. JUNCTION BOXES/CONDUIT ENTRY BOXES SHALL BE MINIMUM NEMA 3R,6X6X4 OR EQUAL. 52.3.6 FOR FLOODED LEAD-ACID,FLOODED NICKEL-CADMIUM AND VRLA BATTERIES,VENTILATION SHALL BE PROVIDED FOR ROOMS AND CABINETS IN ACCORDANCE WITH THE
<br /> 50. RECONNECT TRANSFORMERLESS INVERTERS SHALL BE CONNECTED WITH EGC. MECHANICAL CODES FOR THE
<br /> 51. IN THE EVENT THAT THE ENGINEER SPECIFIES SERVICE RATED DISCONNECTS,BREAKERS,AND/OR MAINS-AND THE NEC DOES NOT REQUIRE THE EQUIPMENT TO BE FOLLOWING:
<br /> SERVICE (1) THE VENTILATION SYSTEM SHALL BE DESIGNED TO LIMIT THE MAXIMUM CONCENTRATION OF HYDROGEN TO 1.0 PERCENT OF THE TOTAL VOLUME OF THE ROOM DURING
<br /> RATED,ELECTRICAL CONTRACTOR SHALL REMOVE THE NEUTRAL TO GROUND BONDING CONDUCTOR/STRAP. THE WORST-CASE EVENT OF
<br /> 52. THE GEC GROUNDING ELECTRODE CONDUCTOR SHALL BE CONTINUOUS/IRREPRESSIBLY SPLICED IN ACCORDANCE WITH NEC SECTION 250.64(C). SIMULTANEOUS"BOOST"CHARGING OF THE BATTERIES,IN ACCORDANCE WITH NATIONALLY RECOGNIZED STANDARDS.
<br /> 53. THE INSTALLATION OF THE PV SYSTEM MUST ALSO BE APPROVED BY THE UTILITY REGARDING THE COMPLIANCE WITH NEC ARTICLE 690. (2) CONTINUOUS VENTILATION SHALL BE PROVIDED AT A RATE NOT LESS THAN 1 CUBIC FOOT PER MINUTE PER SQUARE FOOT OF FLOOR AREA OF THE ROOM OR CABINET.
<br /> 54. ALL ELECTRICAL PANEL SCHEDULES SHALL BE UPDATED BY ELECTRICAL CONTRACTOR. ENVIRONMENT
<br /> 55. ALL NEW ELECTRICAL EQUIPMENT SHALL BE LISTED BY AN OSHA NATIONALLY RECOGNIZED TESTING LABORATORY PER NEC SECTION 90.7. 52.3.7 THE BATTERY ENVIRONMENT SHALL BE CONTROLLED OR ANALYZED TO MAINTAIN TEMPERATURE IN A SAFE OPERATING RANGE FOR THE SPECIFIC TECHNOLOGY USED.
<br /> 56. INSTALLATION OF THE ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH NEC SECTIONS 110.13 AND 110.10. SIGNS
<br /> 57. ALL NEW ELECTRICAL EQUIPMENT SHALL NOT BE INSTALLED IN CLOSETS IN ACCORDANCE WITH NEC SECTIONS 110.26(B)AND 240.24(D). 52.3.8.1 DOORS OR ACCESSES INTO ROOMS,BUILDINGS OR AREAS CONTAINING STATIONARY STORAGE BATTERY SYSTEMS SHALL BE PROVIDED WITH APPROVED SIGNS. Sheet Name
<br /> 58. ALL NEW ELECTRICAL EQUIPMENT SHALL NOT BE INSTALLED IN BATHROOMS IN ACCORDANCE WITH NEC SECTIONS 240.24(E)AND 690.4(E). 53.3.8.2 THE SIGNS REQUIRED BY 52.3.8.1 SHALL STATE THAT THE ROOM CONTAINS STATIONARY STORAGE BATTERY SYSTEMS,THAT THE BATTERY ROOM CONTAINS
<br /> 59. PV SYSTEM CIRCUIT CONDUCTORS SHALL BE SIZED IN ACCORDANCE WITH NEC SECTION 690.8(8)AND PV SYSTEM OVERCURRENT PROTECTION SHALL BE IN ENERGIZED ELECTRICAL CIRCUITS,AND THAT
<br /> ACCORDANCE THE BATTERY ELECTROLYTE,WHERE PRESENT,ARE CORROSIVE LIQUIDS.
<br /> S
<br /> WITH NEC SECTION 690.9. 52.3.8.3 BATTERY CABINETS SHALL BE PROVIDED WITH EXTERIOR LABELS THAT IDENTIFY THE MANUFACTURER AND MODEL NUMBER OF THE SYSTEMS AND ELECTRICAL
<br /> 60. BATTERY SYSTEM CIRCUIT CONDUCTORS SHALL BE SIZED IN ACCORDANCE WITH NEC SECTION 706.20 AND BATTERY SYSTEM OVERCURRENT PROTECTION SHALL BE IN VOLTAGE RATING(VOLTAGE AND CURRENT)OF THE CONTAINED BATTERY SYSTEM.
<br /> ACCORDANCE WITH NEC SECTION 706.21. 52.3.8.4 SIGNS SHALL BE PROVIDED WITHIN BATTERY CABINETS TO INDICATE RELEVANT ELECTRICAL,CHEMICAL AND FIRE HAZARD.
<br /> 61. INTERACTIVE INVERTER CIRCUIT CONDUCTORS SHALL BE SIZED IN ACCORDANCE WITH NEC SECTION 705.60 AND INTERACTIVE INVERTER OVERCURRENT PROTECTION SEISMIC PROTECTION Sheet Size
<br /> SHALL BE IN ACCORDANCE WITH NEC SECTION 705.65. 52.3.9 IN SEISMICALLY ACTIVE AREAS,BATTERY SYSTEMS SHALL BE SEISMICALLY BRACED IN ACCORDANCE WITH THE BUILDING CODE. MS
<br /> 62. ALL NEW ELECTRICAL EQUIPMENT AND CONDUCTORS SHALL BE IDENTIFIED FOR USE IN THE OPERATING ENVIRONMENT IN ACCORDANCE WITH NEC SECTION 110.11. SMOKE DETECTION I B
<br /> 63. ALL NEW/MODIFIED SERVICE ENTRANCE CONDUCTORS,FEEDERS AND BRANCH CIRCUITS SHALL COMPLY WITH NEC SECTIONS 230.42,215.2,AND 210.19,RESPECTIVELY. 52.3.10 AN APPROVED AUTOMATIC SMOKE DETECTION SYSTEM SHALL BE INSTALLED IN SUCH AREAS AND SUPERVISED BY AN APPROVED CENTRAL,PROPRIETARY,OR REMOTE
<br /> STATION SERVICE OR A LOCAL ALARM THAT WILL GIVE AN AUDIBLE SIGNAL AT A CONSTANTLY ATTENDED LOCATION. 1 1"X I T