My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9413 2ND DR SE 2024-10-11
>
Address Records
>
2ND DR SE
>
9413
>
9413 2ND DR SE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2024 10:52:33 AM
Creation date
9/9/2024 8:59:52 AM
Metadata
Fields
Template:
Address Document
Street Name
2ND DR SE
Street Number
9413
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IQBM and IQBA Microinverters <br /> INPUT 1ATA(DCI 108M-72-2-US1: <br /> Commonly used module pairings' w 260-460 295-500 <br /> Module compatibility 54-cell/108 half-cell,60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell <br /> MPPT voltage range V 30-45 32-45 <br /> Operating range V 16-58 <br /> Min./Max.start voltage V 22/58 <br /> Max.input DC voltage V 60 <br /> Max.continuous input DC current A 12 <br /> Max.input DC short-circuit current A 25 <br /> Max.module I A 20 <br /> Overvoltage class DC port II <br /> DC port backfeed current mA 0 <br /> PV array configuration 1 x 1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit <br /> OUTPUT DATA 1: 1: <br /> Peak output power VA 330 366 <br /> Max.continuous output power VA 325 349 <br /> Nominal(L-L)voltage/range V 240/211-264 <br /> Max.continuous output current A 1.35 1.45 <br /> Nominal frequency Hz 60 <br /> Extended frequency range Hz 47-68 <br /> AC short circuit fault current over 2 <br /> 3 cycles Arms <br /> Max.units per 20 A(L-L)branch circuit' 11 <br /> Total harmonic distortion <5 <br /> Overvoltage class AC port III <br /> AC port backfeed current mA 30 <br /> Power factor setting 1.0 <br /> Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging <br /> Peak efficiency % 97.8 97.7 <br /> CEC weighted efficiency % 97.5 97 <br /> Night-time power consumption mW 60 <br /> MECHANICAL DATA <br /> Ambient temperature range -40°C to+60°C(-40°F to+140°F) <br /> Relative humidity range 4%to 100%(condensing) <br /> DC Connector type MC4 <br /> Dimensions(H x W x D) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") <br /> Weight 1.08 kg(2.38 lbs) <br /> Cooling Natural convection-no fans <br /> Approved for wet locations Yes <br /> Pollution degree PD3 <br /> Enclosure Class II double-insulated,corrosion resistant polymeric enclosure <br /> Environ.category/UV exposure rating NEMA Type 6/outdoor <br /> 1 CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB 3r1 Ed.),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 <br /> Certifications This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1- <br /> 2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. <br /> (1)Pairing PV modules with wattage above the limit may result in additional clipping losses.See the compatibility calculator at <br /> https://Iink.enphase.com/module-compatibility.(2)Nominal voltage range can be extended beyond nominal if required by the utility. <br /> (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8MA-I2A-DS-0069-03-EN-US-2022-12-27 <br />
The URL can be used to link to this page
Your browser does not support the video tag.