Laserfiche WebLink
Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This tool will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> Please complete the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you.If you do not see the selection you need in the drop-down options,please contact the WSU Energy Program at <br /> energycode@energy.wsu.edu or(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Hong Property <br /> 0 All Other Systems Qe Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions" <br /> Design Temperature <br /> Instructions Design Temperature Difference(AT) 49 <br /> Everett✓are.AFEi • <br /> A T=Indoor(70 degrees).Outdoor Design Temp <br /> e. n4 r-t Hir-inr, <br /> Conditioned Floor Area <br /> iu5truc:t; Conditioned Floor Area(sq ft) 1.080 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.0 8,640 <br /> Glazing and Dr- U-Factor X Area = UA <br /> Instructions <br /> u•o.3o . 0.300 144 43.20 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 <br /> Insulation <br /> Awe U-Factor X Area = UA <br /> Instructions I R-49 ♦ 0.026 1,080 28.08 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions <br /> ,u vanfec Ce riy5 rn this pi„lent ♦ "" _ <br /> Above Grade Wails(see Figure 1) U-Factor X Area UA <br /> Instructions R.7t intennedate • 0.056 1,056 59.14 <br /> Floors U-Factor X Area UA <br /> Instructions 1t-30 ♦ 0.029 1,080 31.32 <br /> Below Grade Walls(see Figural) U-Factor X Area UA <br /> No Below Grade Walls in this project • 0.028 _ <br /> Slab Below Grade(see Figure 1) F-Factor X Len UA <br /> ho Sian Below Grade in this project. • 0.303 --- <br /> Slab on Grade(see Figure 1) F-Factor X Length UA <br /> t:c SIa7 a ,'.r:7e i th s prolec-_ ♦ <br /> Location of Ducts, <br /> Instruction` Duct Leakage Coefficient <br /> Unconditioned Space ♦ <br /> 1.10 <br /> Sum of UA 161.74 <br /> Envelope Heat Load 7,925 Btu/Hour <br /> Figural. Sum of UA x AT <br /> Air Leakage Heat Load 4,572 Btu/Hour <br /> Volumes- 0.6 x AT x 0.018 <br /> • Above Grade Building Design Heat Load 12,497 Btu/Hour <br /> Air leakage+envelope heat loss <br /> Building and Duct Heat Load 13,747 Btu/Hour <br /> Ducts in unconditioned space:sum of building heat loss x 1.10 <br /> Ducts in conditioned space:sum of building heat loss x 1 <br /> Maximum Heat Equipment Output 17,184 Btu/Hour <br /> Building and duct heat loss x 1.40 for forced air furnace <br /> Building and duct heat loss x 1.25 for heat pump <br /> (07/01/13) <br />