My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9001 AIRPORT RD 2024-10-11
>
Address Records
>
AIRPORT RD
>
9001
>
9001 AIRPORT RD 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 10:45:47 AM
Creation date
9/11/2024 10:16:15 AM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
9001
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ES-LF009 <br /> Engineering • - • <br /> Job Name Contractor <br /> Job Location Approval <br /> Engineer Contractor's P.O. No. <br /> Approval Representative <br /> Series LF009 <br /> Reduced Pressure Zone Assemblies <br /> Sizes: '/4" - 3" <br /> Series LF009 Reduced Pressure Zone Assemblies are designed to . <br /> protect potable water supplies in accordance with national plumbing <br /> codes and water authority requirements.This series can be used in a <br /> variety of installations, including the prevention of health hazard cross- <br /> connections in piping systems or for containment at the service line <br /> entrance.The LF009 features Lead Free`construction to comply with LF009 <br /> Lead Free*installation requirements. <br /> This series features two in-line, independent check valves,captured <br /> springs and replaceable check seats with an intermediate relief valve. <br /> Its compact modular design facilitates easy maintenance and assem- <br /> bly access. Sizes 1/4"-1"shutoffs have tee handles. Test Cock No.3 <br /> Test Cock No.4 <br /> Ball Type <br /> Features Test Cocks <br /> •Single access cover and modular check construction for Test Cock <br /> ease of maintenance No 2 O <br /> •Top entry-all internals immediately accessible <br /> • Second <br /> Captured springs for safe maintenanceFirst Check <br /> Check <br /> •Internal relief valve for reduced installation clearances Module Module <br /> •Replaceable seats for economical repair Assembly Assembly <br /> •Lead Free*cast copper silicon alloy body construction for durability <br /> 1/4"-2" <br /> •Fused epoxy coated cast iron body 2'/2"and 3" R.P.Zone <br /> •Ball valve test cocks — screwdriver slotted 1/4"-2" Water Outlet <br /> Relief Valve Assembly <br /> •Large body passages provides low pressure drop <br /> •Compact, space saving design <br /> •No special tools required for servicing Now Available <br /> Specifications WattsBox Insulated Enclosures. <br /> A Reduced Pressure Zone Assembly shall be installed at each potential For more information, send for literature ES-WB. <br /> health hazard location to prevent backflow due to backsiphonage and/ <br /> or backpressure.The assembly shall consist of an internal pressure <br /> differential relief valve located in a zone between two positive seating <br /> check modules with captured springs and silicone seat discs. Seats and Inquire with governing authorities for local installation requirements <br /> seat discs shall be replaceable in both check modules and the relief <br /> valve.There shall be no threads or screws in the waterway exposed to <br /> line fluids.Service of all internal components shall be through a single <br /> access cover secured with stainless steel bolts. Body and shutoffs shall <br /> be constructed using Lead Free*cast copper silicon alloy materials. The information contained herein is not intended to replace the full <br /> Lead Free*reduced pressure zone assembly shall comply with state product installation and safety information available or the experience <br /> codes and standards,where applicable, requiring reduced lead content. of a trained product installer.You are required to thoroughly read all <br /> The assembly shall also include two resilient seated isolation valves, installation instructions and product safety information before begin- <br /> four resilient seated test cocks and an air gap drain fitting.The assem- ning the installation of this product. <br /> bly shall meet the requirements of: USC;ASSE Std. 1013;AWWA Std. <br /> C511;CSA B64.4.Shall be a Watts Series LF009. *The wetted surface of this product contacted by consumable <br /> water contains less than 0.25%of lead by weight. <br /> Watts product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measurements, VAWATM <br /> please contact Watts Technical Service.Watts reserves the right to change or modify product design,construction,specifications,or materials with <br /> - <br /> out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. <br />
The URL can be used to link to this page
Your browser does not support the video tag.