i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> Permit Number: P2302-006 Description: PLUMBING-UNDER SLAB DRAINS FOR ACCESSORY <br /> BUILDING <br /> Applied:2/6/2023 Approved: 2/6/2023 Site Address: 2316 GRAND AVE <br /> Issued:2/6/2023 Finaled: City,State Zip Code: EVERETT,WA 98201-2714 <br /> Status: EXPIRATION NOTICE SENT Applicant: ROBERT CARKEEK <br /> Parent Permit: B2111-061 Owner:CARKEEK ROBERT J <br /> Parent Project: Contractor: OWNER <br /> Details: <br /> SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS <br /> PLUMB 02- CORRECTION <br /> 2/28/2023 2/28/2023 GROUND JEFF M RHODE REQUIRED see notes <br /> WORK/SLAB <br /> Notes: <br /> -no vent on floor drain trap <br /> 901.2 Vents Required <br /> Each plumbing fixture trap,except as otherwise provided in this code,shall be protected against siphonage and backpressure,and air circulation shall <br /> be ensured throughout all parts of the drainage system by means of vent pipes installed in accordance with the requirements of this chapter and as <br /> otherwise required by this code. <br /> -trap primer needed for floor drain <br /> 1007.1 General <br /> Floor drain or similar traps directly connected to the drainage system and subject to infrequent use shall be protected with a trap seal primer,except <br /> where not deemed necessary for safety or sanitation by the Authority Having Jurisdiction.Trap seal primers shall be accessible for maintenance. <br /> -waste and vent underground system not tested with 10 feet of head pressure <br /> 712.2 Water Test <br /> The water test shall be applied to the drainage and vent systems either in its entirety or in sections.Where the test is applied to the entire system, <br /> openings in the piping shall be tightly closed,except the highest opening,and the system filled with water to the point of overflow.Where the system is <br /> tested in sections,each opening shall be tightly plugged,except the highest opening of the section under test,and each section shall be filled with <br /> water,but no section shall be tested with less than a 10 foot head of water(30 kPa). In testing successive sections,not less than the upper 10 feet(3048 <br /> mm)of the next preceding section shall be tested,so that no joint or pipe in the building(except the uppermost 10 feet(3048 mm)of the system)shall <br /> have been submitted to a test of less than a 10 foot head of water(30 kPa).The water shall be kept in the system,or in the portion under test,for not <br /> less than 15 minutes before inspection starts.The system shall then be tight at all points. <br /> -toilet and sink located in utility room at back of shop <br /> PLUMB 02- CORRECTION <br /> 3/2/2023 3/2/2023 GROUND JEFF M RHODE REQUIRED see notes <br /> WORK/SLAB <br /> Notes: <br /> -add vent for floor drain <br /> 901.2 Vents Required <br /> Each plumbing fixture trap,except as otherwise provided in this code,shall be protected against siphonage and backpressure,and air circulation shall <br /> be ensured throughout all parts of the drainage system by means of vent pipes installed in accordance with the requirements of this chapter and as <br /> otherwise required by this code. <br /> -non metal shielded coupling on abs waste pipe replace with metal shielded coupling <br /> I <br /> Printed:Thursday, 12 September,2024 1 of 3 rk <br /> SUPERION <br />