My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA C403.4.1.6 Door switches for Doors required to have opening switches for <br /> HVAC system HVAC thermostatic control to the outdoors <br /> thermostatic control from a conditioned space and are>48 sf, <br /> indicate automatic controls configured to <br /> setback the HVAC system(s)when the door is <br /> open for>5 minutes;indicate method of <br /> HVAC system setback control(turns off the <br /> HVAC system or resets the heating setpoint to <br /> 55°F and cooling setpoint to 85°F),or <br /> exception applied(either C402.5.11 or <br /> C403.4.1.6) <br /> NA C403.4.2 Automatic setback Indicate zone thermostatic controls configured <br /> C403.4.2.1 and shutdown with required automatic setback and manual <br /> C403.4.2.2 override functions,setback temperatures,and <br /> control method(automatic time clock or 7 day <br /> programmable controls);note exceptions <br /> applied <br /> NA C403.4.2.3 Automatic(optimum) Indicate all HVAC systems are provided with <br /> start and stop automatic start and stop controls;indicate start <br /> controls are configured to adjust the <br /> equipment start time as required to bring each <br /> area served up to design temperature just <br /> prior to scheduled occupancy;indicate stop <br /> controls are configured to reduce heating <br /> setpoint and increase cooling setpoint by at <br /> least 2°F prior to scheduled unoccupied <br /> periods <br /> NA C403.4.2.4 Exhaust system off- For exhaust systems serving conditioned <br /> hour controls spaces in all occupancies other than Group R, <br /> indicate method of control and that controls <br /> are configured to turn exhaust systems on and <br /> off in concert with the ventilation air systems <br /> providing their make-up air,or exception <br /> applied <br /> NA C403.4.2.5 Transfer and For transfer fan or mixing fan systems serving <br /> destratification fan conditioned spaces in all occupancies other <br /> system off-hour than Group R,indicate method of control and <br /> controls that controls are configured to turn fans on <br /> and off in concert with the associated HVAC <br /> systems,or exception applied <br /> NA C403.4.7 Combustion heating For combustion heating equipment other than <br /> equipment boilers or radiant heaters with output capacity <br /> >225,000 Btu/h,indicate modulating or <br /> staged combustion control <br /> NA C403.4.7.1 Combustion Indicate controls that are configured to limit <br /> decorative vented operation of combustion appliance,fireplace <br /> appliance, and fire pit to< 1 hour without override,or <br /> combustion fireplace that occupancy sensor controls are provided <br /> and fire pit controls <br /> Page 14132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.