My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL DATA-GCS16 <br /> General Model No. GCS16-024 GCS16-030 GCS16-036 <br /> Data Line voltage data-60 hz 2081230v-1 ph 2081230v-1 ph 208/230v-1 ph 208/230v-3ph 460v-3ph 575v-3ph <br /> Recommended maximum fuse size(amps) 25 30 40 25 15 15 <br /> tMinimum Circuit Ampacity 16 20 25 18 10 8 <br /> Compressor Rated load amps 10.1 12.4 16 10.3 5.1 4.2 <br /> Locked rotor amps 60 69.4 100 77 39 31 <br /> Condenser Coil Full load amps 1.1 1.1 1.1 1.1 .80 E3.80 <br /> Fan Motor <br /> Lacked rotor amps 2.3 2.3 2.3 2.3 1.9 p1.9 <br /> Evaporator Motor output-hp(W) 113(249) 1/3(249) 112(373) 1/2(373) 112(373) 1/2(373) <br /> Blower Motor Full load amps 2.2 3.0 3.9 3.9 1.9 p1.9 <br /> Locked rotor amps 4.2 6.2 8.3 8.3 4.2 X4.2 <br /> Combustion Air Inducer Motor(1 phase)full load amps 0.7 0.7 0.7 0.7 0.7 0.7 <br /> tRefer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. <br /> nMotors are rated at 460 volts.Full load amps shown are for step-dawn transformer output. <br /> NOTE-Extremes of operating range are plus and minus 10%of line voltage. <br /> ELECTRICAL 1 <br /> General Model No. GCS16-048 GCS16-060 <br /> Data Line voltage data-60 hz 2081230v-1 ph - p Ov-3ph 575v-3ph 208/230v-1 ph 208/230v-3ph 0v-3ph 575v-3ph <br /> Rec.maximum fuse size(amps) 50 35 15 15 60 45 20 15 <br /> tMinimum Circuit Ampacity 34 23 12 10 42 29 16 12 <br /> Compressor Rated load amps 21.8 12.8 6.4 5.1 27.6 17.6 9.5 6.3 <br /> Locked rotor amps 131 91 46 37 135 105 55 45 <br /> Condenser Coil Full load amps 2 2 1.1 ❑t 1.1 2 2 1.1 E]1.1 <br /> Fan Motor Locked rotor amps 4.2 4.2 2.2 [E2.2 4.2 4.2 2.2 p2.2 <br /> Evaporator Motor output-hp(W) 3/4(560) 3/4(560) 3 4(560) 3/4(560) 3/4(560) 314(560) Y4(560) 3/4(560) <br /> Blower Motor Full load amps 4.6 4.6 2.4 p2.4 4.6 4.6 2.4 p2.4 <br /> Locked rotor amps 10.1 10.1 5.0 p5.0 10.1 10.1 5.0 [E5,0 <br /> Combustion Air Inducer Motor(1 phase)full 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 <br /> load amps <br /> tRefer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. <br /> pMotors are rated at 460 volts.Full load amps shown are for step-down transformer output. <br /> NOTE-Extremes of operating range are plus and minus 10%of line volbge. <br /> ELECTRICAL1 1 <br /> General Model No. GCS20-036 OCS20-048 GCS20-060 <br /> Data Line voltage data-60 hz 20B/230v-3ph 460v-3ph 208/230v,3ph 460v-3ph 208/230v-3ph 460v-3ph <br /> Recommended maximum fuse size(amps) 25 15 40 20 45 20 <br /> tMinimum Circuit Ampacity 19 10 24 13 29 14 <br /> Compressor Rated load amps 10.3 5.1 14.7 7.1 17.3 8.2 <br /> Locked rotor amps 77 39 91 50 123 62 <br /> Condenser Coil Full load amps 2.0 1.1 2.0 1.1 2 1.1 <br /> Fan Motor <br /> Locked rotor amps 4.2 2.2 4.2 2.2 4.2 2.2 <br /> Evaporator Motor output-hp(W) 1/2(373) 1/2(373) 3/4(560) 1/2(373) 3/4(560) 3/4(560) <br /> Blower Motor <br /> Full load amps 3.9 1.9 5,0 2.4 5.0 2.4 <br /> Locked rotor amps 8.3 4.2 10.1 5.0 10.1 5 <br /> Combustion Air Inducer Motor(1 phase)full load amps 0.7 0.7 0.7 0.7 0.7 0.7 <br /> tRefer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. <br /> NOTE-Extremes of operating range are plus and minus 10%of line voltage. <br /> r_rc�wr_rc,)n-7 4n K Tnn/Pana 1 R► <br />
The URL can be used to link to this page
Your browser does not support the video tag.