My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2525 W CASINO RD BASE FILE 2024-10-24
>
Address Records
>
W CASINO RD
>
2525
>
BASE FILE
>
2525 W CASINO RD BASE FILE 2024-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2024 9:49:34 AM
Creation date
9/18/2024 9:02:51 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
2525
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DAILY FIELD REPORT Inspection <br /> Date <br /> r AAR TESTING AND INSPECTION, INC. 05/30/2024 <br /> 7126 180th Ave NE, Suite C101 Report <br /> Redmond, WA 98052 Number <br /> 425-881-5812 TID053024B <br /> CLIENT INFORMATION PROJECT INFORMATION <br /> Contact Neil Montague Project No. 24-316 <br /> Company Northwest Handling Systems Project Name Aviation Technical Services <br /> (PO#01EA240327B) <br /> Address 1100 SW 7th St Address 2525 West Casino Rd Suite 7G <br /> City Renton City Everett <br /> Contractor Permit No. B2404-045 <br /> INSPECTION TYPE(S) STRUCTURE(S) / LOCATION(S) <br /> O Proprietary Anchors - Mechanical 1/2" Hilti KBTZ2 wedge anchors at North warehouse floor <br /> Weather Temperature (OF) Start Time End Time <br /> Sunny 55 10:00 AM 02:00 PM <br /> DRAWINGS/ DOCUMENTS REFERENCED <br /> Approved plans <br /> INSPECTION OBSERVATION / REMARKS <br /> As requested, I was on site to inspect the installation of 1/2" Hilti KBTZ2 wedge anchors into existing concrete at the above noted locations for <br /> storage racks. When on site I reviewed the project drawings sheet, and ESR Report 4266. <br /> I verified that the approved anchors were installed to the required embedment depth of 4 inches with 2 anchors per base plate. <br /> I used a calibrated torque wrench to verify tightening torque on the anchor nuts and found that the nuts were tightened to at least 50 foot <br /> pounds. <br /> Work was performed per ESR Report 4266, manufacturer's directions and the project plans. <br /> Items inspected are in conformance with approved plans, specifications, and jurisdictional requirements <br /> Inspectors Signature Inspectors Name Report Date Reviewers Reviewed By Reviewed Date <br /> / Tony Dalzell 05/31/2024 Signature Teajalam (TJ) <br /> / Gounden <br /> 5270e64939402c42-1717163076484 <br />
The URL can be used to link to this page
Your browser does not support the video tag.