Laserfiche WebLink
SECTION 5 MUST BE COMPLETED BY THE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. <br />PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN — USING THEIR PROSPECTIVE <br />RESIDENT BEDROOM DESIGNATIONS OF A 8 C D E AND F AND CLASSIFICATION CODE S, NS1 OR NS2. <br />SECTION 5 — BUILDING INSPECTOR'S INSPECTION CHECKLIST <br />R330.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: <br />Type S — where the means of egress contains stairs, elevators or platform lifts to evacuate residents to public area. <br />Type NS1— where 1 means of egress at grade level (has no stairs) or ramp constructed compliant with R330.9 is provided to evacuate <br />residents to public area. <br />Type NS2 — where 2 means of egress at grade level (both have no stairs) or ramps constructed compliant with R330.9 are provided to <br />evacuate residents to public area. <br />SLEEPING ROOM A 113 Type S Type NS1 113 Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside JE3 Yes 113 No I RN/A I Smoke alarm is installed in the bedroom <br />0 <br />Bedroom door opens easily and quickly from the outside when locked <br />■ <br />0 <br />Sleeping room window has a net opening of S.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />JR <br />0 <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />13 <br />SLEEPING ROOM B <br />10 Type S INType NS1 113 Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside 10 Yes � No I N/A I Smoke alarm is installed in the bedroom <br />13 <br />Bedroom door opens easily and quickly from the outside when locked <br />0 <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />13 <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed13 <br />SLEEPING ROOM C 113 Type S JIM Type NS1 OType NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside 10 Yes F[3 No I NIN/A I Smoke alarm is installed in the bedroom <br />[] <br />Bedroom door opens easily and quickly from the outside when locked <br />13 <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />E <br />13 <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />S <br />13 <br />SLEEPING ROOM D 10Type S IN Type NS1 10Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside JE3 Yes JE3 No I EN/A I Smoke alarm is installed in the bedroom <br />M <br />Bedroom door opens easily and quickly from the outside when locked <br />E <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />® <br />13 <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />0 <br />0 <br />SLEEPING ROOM E 10 Type S N Type NS1 [3Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside 10 Yes JQNo NN/A I Smoke alarm is installed in the bedroom <br />W <br />13 <br />Bedroom door opens easily and quickly from the outside when locked <br />i <br />0 <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />® <br />13 <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />9 <br />13 <br />SLEEPING ROOM F 113 Type S I EType NSi 113 Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside JE3 Yes 0 No I WN/A I Smoke alarm is installed in the bedroom <br />R <br />Bedroom door opens easily and quickly from the outside when locked <br />10 <br />0 <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />0 <br />13 <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />e <br />0 <br />Implementation Date: 2021 February 01 <br />Updated: 2021 February <br />