Allowable Stress Design Loads <br /> 2016 Envelope Procedure 2016 Equiv.Lateral Force Procedure <br /> Wind Load Combination Seismic Load Combination <br /> 0.6D+0.6W+H (0.6-0.14Sos)D+0.7pQE+H <br /> %ofDLusedinOT %of DL used in OT <br /> 60% 45% <br /> Wind Design Loads Fx Seismic Design Loads,Fx <br /> P= 1.30 1.30 <br /> Transverse Longitudinal Transverse Longitudinal <br /> Diaphragm Force(Ibs) Force(Ibs) Diaphragm Force(Ibs) Force(Ibs) <br /> 1 5856 5064 1 7078 7078 <br /> Principle of Mechanics-cont. <br /> Where, v= shear per linear foot of shearwall P <br /> w= width of shearwall p <br /> h= height of shearwall <br /> D= resisting dead load centered over shearwall h x <br /> P= resisting dead load at end of shearwall <br /> Shearwall calculations follow,where, <br /> h <br /> Vx Total force in the diaphragm above story(x),pounds(lbs) <br /> Percent of Vx tributary to the shearwalls(SW)in the wall line <br /> VDx Force from the diaphragm above that transfers to the SW's,lbs <br /> VTx., Force from the SW's above that transfers to the SW's,lbs <br /> VTx Total force in the SW's(VD,+VTx,1),lbs <br /> or.EUTIKESt <br /> l <br /> of <br /> (ft <br /> L Total reorce in teSW's w), feet pounds <br /> Linear force in the SW's(VTx/L),pounds per foot(plf) <br /> F Greater of v induced by wind or earthquake,plf <br /> Max Tx Maximum uplift force of the SW's,lbs Free Body Diagram of a ShearWall <br /> I's Greater of v in the sheathing induced by wind per 2306.4.1 or earthquake per 2305.3.4,plf <br /> w Width of SW,ft <br /> h Height of SW,ft <br /> dr Tributary distance of roof(used to calculate D)along the width of the SW,ft <br /> dra Tributary distance of roof(used to calculate P)adjacent to the width of the SW,ft <br /> df Tributary distance of floor(used to calculate D)along the width of the SW,ft <br /> dfa Tributary distance of floor(used to calculate P)adjacent to the width of the SW,ft <br /> Twx+, Wind uplift force of the SW above that transfers to the SW, lbs <br /> Twx Wind uplift force of the SW,lbs <br /> Tex+f Earthquake uplift force of the SW above that transfers to the SW, lbs <br /> Tex Earthquake uplift force of the SW,lbs <br /> 220207_SSSlateral (LOT 2)_221010_API_ DL <br />
The URL can be used to link to this page
Your browser does not support the video tag.