My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1725 106TH ST SW 2023 Plans 2024-09-25
>
Address Records
>
106TH ST SW
>
1725
>
Plans
>
1725 106TH ST SW 2023 Plans 2024-09-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2024 11:21:27 AM
Creation date
9/25/2024 8:25:48 AM
Metadata
Fields
Template:
Address Document
Street Name
106TH ST SW
Street Number
1725
Permit
B2307-065
Year
2023
Notes
REMODEL RESIDENCE & CONVERT GARAGE INTO LIVING SPACE FOR AFH
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WALL CONSTRUCTION <br /> TABLE R602.3(1) <br /> FASTENING SCHEDULE k <br /> ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE SPACING AND LOCATION <br /> OF FASTENER","'" <br /> Roof <br /> 4-8d box(21/2"x 0.113")or <br /> 1 Blocking between ceiling joists or rafters to top plate 3-8d common(21/2"x 0.131");or Toe nail <br /> 3-10d box(3 x 0.1281);or <br /> 3-3"x 0.131"nails <br /> - 4-8d box(21/2"x 0.113');or <br /> 2 Ceiling joists to top plate 3-8d common(21/2"x 0.131');or Per joist,toe nail <br /> 3-10d box(3"x 0.128');or <br /> 3-3"x 0.131"nails <br /> 4-10d box(3"x 0.1281);or <br /> 3 Ceiling joist not attached to parallel rafter,laps over 3-16d common(31/2"x 0.1621);or Face nail <br /> partitions(see Section R802.5.2 and Table R802.5.2) 4-3"x 0.131"nails <br /> 4 Ceiling joist attached to parallel rafter(heel joint) Table R802.5.2 Face nail <br /> (see Section R802.5.2 and Table R802.5.2) <br /> Collar tie to rafter,face nail or 11/4"x 20 ga.ridge strap to 4 lOd box(3"x 0.128");or <br /> 5 3-10d common(3"x 0.148');or Face nail each rafter <br /> rafter 4-3"x 0.131"nails <br /> 3-16d box nails(31/2"x 0.135");or 2 toe nails on one side and 1 toe nail <br /> 3-lOd common nails(3"x 0.148�;or on opposite side of each rafter or <br /> 6 Rafter or roof truss to plate 4-10d box(3"x 0.128');or truss <br /> 4-3"x 0.131"nails <br /> 4-16d(31/2"x 0.135');or <br /> 3-10d common(3"x 0.148');or Toe nail <br /> 4-10d box(3"x 0.128');or <br /> Roof rafters to ridge,valley or hip rafters or roof rafter 4-3"x 0.131"nails <br /> 7 <br /> to minimum 2"ridge beam 3-16d box 31/2"x 0.135`1;or <br /> 2-16d common(31/2"x 0.162");or End nail <br /> 3-10d box(3"x 0.128");or <br /> 3-3"x 0.131"nails <br /> Wall <br /> 16d common(31/2"x 0.162') 24"o.c.face nail <br /> 8 Stud to stud(not at braced wall panels) 10d box(3"x 0.128);or 16" <br /> 3"x 0.131"nails o.c.face nail <br /> 16d box(31/2"x 0.135');or 12"o.c.face nail <br /> 9 Stud to stud and abutting studs at intersecting wall corners 3"x 0.131"nails <br /> (at braced wall panels) 1 <br /> 16d common(31/2"x 0.162') 16 o.c.face nail <br /> 10 Built-up header(2"to 2"header with 1/2"spacer) 16d common(31/2"x 0.162") 16"o.c.each edge face nail <br /> 16d box(31/2"x 0.135') 12"o.c.each edge face nail <br /> 5-8d box(21/2"x 0.113');or <br /> 11 Continuous header to stud 4-8d common(21/2"x 0.1311);or Toe nail <br /> 4-10d box(3"x 0.128') <br /> 16d common(31/2"x 0.162') 16"o.c.face nail <br /> 12 Top plate to top plate 10d box(3"x 0.1281);or 12" <br /> 3"x 0.131"nails o.c.face nail <br /> 8-16d common(31/2"x 0.162');or Face nail on each side of end joint <br /> 12-16d box(31/2"x 0.135');or minisplice 13 Double top plate splice l2-lOd box(3"x 0.128');or (minimum 24"lap length each <br /> 12-3"x 0.131"nails side of end joint) <br /> (continued) <br /> 174 2018 INTERNATIONAL RESIDENTIAL CODE® <br />
The URL can be used to link to this page
Your browser does not support the video tag.