My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8531 EVERGREEN WAY 2023 COMMUNITY HEALTH CENTER Plans 2025-03-26
>
Address Records
>
EVERGREEN WAY
>
8531
>
COMMUNITY HEALTH CENTER
>
Plans
>
8531 EVERGREEN WAY 2023 COMMUNITY HEALTH CENTER Plans 2025-03-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/26/2025 7:57:27 AM
Creation date
9/25/2024 9:50:51 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8531
Tenant Name
COMMUNITY HEALTH CENTER
Permit
M2304-034
Year
2023
Notes
INSTALL MULTIPLE UNITS AND ASSOCIATED REFRIGERATION PIPING
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TURNING VANES REQUIRED IF NOTE SOLINDISE LAMS REOD <br /> • <br /> AIR VELOCITY IS GRFATEq THAN jr �� r — - LEPACE NCRC.30 OR ` N . yy (,/ BOO FPM DUCT TEMP.55'F • <br /> Q r <br /> � 1• r SEE GErvERAL NOTES li <br /> �,RAOfUS ELBOWLIE FOR MAXIMUM y <br /> REO'D WHEN AIR LENGTH H e rma n son <br /> T SHEET METAL OR DUCT <br /> R VELOCITY IS APPROX TO.C. BOARD AS NOTED UBOLT <br /> ROVE 2020 FPM /\ 1Z'M.Ut SWIVEL CONNECTOR 1TOO. Building Today,Defining Tomorrow <br /> �_f R-ni.w TOP. <br /> SQUARE ELBOW DETAIL OF TURNING VANE EQUAL SPLIT SQUARE TEE I Nelmortwn Compo�ry UP <br /> RADIUS ELBOW J 1221 2rA Armue Henn <br /> f L Kent 1W*.M1inq/In 98032 <br /> �� I � >w•uAx f, If. �.I,��.�:�I',�x�`�. ��� �a.:(zasj sis�-BTe�m <br /> L.iW,1'MIN. HEIGH '4114.T <br /> �"i.l wxx.Nerma+soncmn <br /> I 1 12"MAXIMUM I I °�. <br /> I Lon,racb RA9�:IEkLW381 <br /> I I W FIDfIBIE DUCTWORK .. . <br /> W ISM 1 <br /> NOTE: <br /> CHC SNOH CO <br /> 3W I A-QS° ) RECO USE OF ME ENTRY DIFFUSER CANS IS PERFORATED PLATE WITH SEISMICBMCING MAY BE M_ka FGRIP:36VRTG91481Pt-®t@INGNB9%IXIIm'�8v LSPIIO FR3AllmMTBES IA TEO- EIRF£4RD RR BOTTOM Of 1TE SIW%:IIRiAL SUPPORT <br /> ITOP INLET <br /> DUCT <br /> ENDED TO DWEBN.1 DIAMETERS A STRAIGHT <br /> FOR THE HANGER THE FORMA DUO ®RIXRO SDIIGMSR�U�ia.G3RI TCBMTHCI3IA deTCRI IOW M IE SOTTDIM OF STRUCTURAL SUPPORT FOR THE SOUTH E V E R E TT <br /> 2 w TOP INLET DUCT TO DtliT3)SFA6NOi AVAILABLE OFHEIGHT OR PER MFG. HANGER'WHERE HANGER'S NWCETALLl30 WA49m�19 (ONFAIINR0ER�'rv'6:m69�9!ICA THAT CA MOT DEVELOP MOMENTS. <br /> /, �_ APPLICABLE ONLY WHERE LATERAL Bm1213193F ITHE1YTWOWNWW41601@iU133ID.YWUPG SAFACISWIROSH�13IFOX MQxCE.1lS CR LOSS OF VERTICAL SUPPORT. <br /> WYE HI HMI V MEDIUM PRESSURE LOW PRESSURE WU2"-- VERIFY APPROVAL WITH LIX'wLCODE MITfO01YPR10R TO INSTALLATION. ANNEX <br /> LOW PRESSURE BOOT DUCT TAP <br /> DEAD HEAD FITTING DUCT TAP MEDIUM PRESSURE 8531 EVERGREEN WAY <br /> (Th TYPICAL DUCT FITTINGS CONICAL TAP n SUPPLY AIR DIFFUSER DETAIL (7.1 SEISMIC DUCT&PIPE BRACING-EXCEPTIONS EVERETT,WA 98208 <br /> MSC, NOT TO SCALE `01 NOT TO SCALE u��g a `j NOT TO SCALE <br /> LOW PRESSURE DUCT INSULATED OR <br /> SOUNOLINED AS SPECIFIED <br /> HANGAR ROD <br /> SOUNDING CANS REOT IF <br /> SPACE NCRC.30 <br /> r <br /> DUCAT BOARD OR SHEET VIBRATION ISOLATORS.WHERE REQUIRED HANGE0.ROD <br /> METAL RETURN AR CAN ,O\\FOOOR 4 <br /> NON-INSULATED%PE <br /> SPIN-IN COLLAR WITH MANUAL hey.y4C <br /> CRIMP 8 BAND STRAP MANGER 3'DOMINO SMALLER - <br /> WI DRAW BAND VOLUME DAMPER.OW ENT DAMPER GG <br /> SHAFT PARALLEL TO DUCT AIR CLEVIS HANGER A'ODIWO LARGER VIBRATION ISOLATORS.WHERE Y 1- <br /> FLOW.GC TO PROVIDE ACCESS REQUIRED ```` <br /> INSULATED FLEX DUCT DOOR IF DAMPER IS LOCATED SPRING LOCK 4 PIPE ���.. <br /> AS SHORT AS POSSIBLE IN AN INACCESSIBLE LOCATION. \ \ '- <br /> / \ INSULATED PIPE WITH PPE SHIELD. INSULATED PIPE WITH PIPE SNIEID A*....\T- <br /> INSULATEDRIGIDROINODUCT \ ` AL> <br /> EXTENSION AS REQUIRED 1 DAMETER STRAIGHT MANGER STRAP PIPE STRAP <br /> TOP INLET PIPE RM.F OR BLOCKING Nay .<�323 <br /> FLEXIBLESUPPORT FLI2 MAXID U T RADIUS IX DMA PIPE SADDLE OR BLOCKING <br /> SUPPORT FLEXIBLE DUCT ALL HANGER WINES HANGAR ROD <br /> RUNS OVER OR ON OF MUST BE VERTICAL <br /> \ SPLAYED) <br /> CENTERS. RIOT SPLAYED) ' <br /> (N = ANGLE RON OR L06TRUT SUPPORT <br /> SEAL FLEXIBLE DUCT VIBRATx)N ISOLATORS.WHERE REWIRED <br /> ""�W"" "APOR IIIIIIIII\�—Milli _ ISSUE FOR PERMIT <br /> ' AND SEA VAPOR <br /> \ BARRIER TAPE(TDUCT <br /> T) [TRAIT CEILING STRAP HANGER 3-W AND SMALLER <br /> CLEWS HANGER e•OD AND LARGER Ke Plan <br /> ,, UNINSULATED PIPE PIPE SHIELD Y <br /> ` LAY\ <br /> R DIFFUSER TYPICAL A DEVICES <br /> AS SCHEDULED(SEE PLANS T-BAR CEILING GRID I�/ <br /> AND EQUIPMENT SCHEDULE) -- <br /> TYPICAL AIR DEVICE LIGHT TYPICAL TRAPEZE TYPE <br /> (Th TRANSFER GRILLE DETAIL (7"\FLEXIBLE CONNECTION (Th LAY-IN DIFFUSER W/DUCT DROP n TYPICAL SINGLE PIPE HANGERS (MULTIPLE PIPE HANGER <br /> `i NOT TO SCALE M`30, NOT TO SORE M`/.01 NOT TO SCALE M5.01 NOT TO SCALE `50I <br /> `., NOT TO SCALE <br /> C.O.PLUG WITH I T <br /> REMOVABLE <br /> INSULATION <br /> CAP(TNT) C OPEN AR VEti'T NONRATED PARTITION <br /> WITH ACCOUSTIAL SEAL <br /> ALTA PRODUCTS FOR USE IN OFFICE AND 18 GAUGE GALVANIZED <br /> SIGRIST(OR EQUAL) STRAPHANGERS TRAPEZE HANGERS CONFERENCE AREAS ANO SLEEVE.t.LARGER THAN <br /> INSULATE ALL PIPING INDIVIDUAL PIPE CHASE WHERE NOTED ON PIPE AND INSULATION <br /> B AS REWIRED FOR REFRIGERANT LANES. HOUSING WITH DRAWINGS. OUTSIDE DAMETER(TIP) <br /> CONDENSATION CONDUIT.ETC INSULATED COVER ROD SIZE FOR LOAD <br /> PROTECTION CONDENSING UNIT AND CURB. ,'WIDE 20 W' PIPE(T T) <br /> A (MAX AOC LBS.) GASKET.TOP AND HANGER STRAP STRAP OR ANGLE <br /> TO FLOOR OR OTHER WEATHERPROOF <br /> DARN LOCATION (yl PENETRATIONS <br /> I.AIR GAP MIN.FOR �'X A'LAG BOLT WATERPROOF PENETRATION: BO"MAX. <br /> EQUIPMENT 7 7 SIGRST END SEAL / INSULATION ITVP) Revisions <br /> INDIRECT TERMINATION VIBRATION f UNLESS FOOT OF ]'WIDE CONTNUW S <br /> MEI W BRATION ISOLATOR. 7 ISOLATION P. (k00 TO I kOD) STRAP IS PLACED ELASTOMERIC SEAL AROUN 3 <br /> DEKTTES FLEXIBLE ( ROOF CANT STRIP AND UNDER A BOTTOM NONRATED PARTITION PIPE OR INSULATION <br /> AS REPUTED DRAIN <br /> BOOT MOD 8 GREATER) ROOFING UP TO TOP REINFORCEMENT. <br /> CONCRETE HOUSEKEEPING SLAB OR ROOF w A SHEET METAL CAP OR EQUAL � `SS OF CURB(BY GC) <br /> SIZP.E AS REWIRED TO ACCOMMODATE AS REQUIRED -IPIPING. I - \\ EESCUTCCHEON FORISHED <br /> TRARDEPM B. <br /> REFRIGERANT LKKIID. ROOFING.BLOCKING } --{ II--1"MIN FIENOSED AREAS IN <br /> TRAPGAS AND ELECTRICAL CONDUIT AND CANT STRIP <br /> A B C (BY GC) SCREWS MAY BE OMITTED SIZE BOLT(S)FOR LOAD <br /> WHERE X.STATIC ATTACH CURB IF HANGER LOOPS <br /> ORAWi11ROlU0M co. X Xr1'MIN.'1'ABOVE PRESSURE AT DRAIN A OROOF <br /> P UP OF PAN HOLE IN PAN <br /> LAP SIZE UC RB 10 HOOF OPENING SCREWS ;•GAP AROUND ENTIRE <br /> _ ROOF CONSTRUCTION TYPICAL NON-RATED PIPE AND <br /> BLOWTMRWGH°OIL XH•MN. 1'MIN. u OF NOTE: MEDIUM SD XX123161Xe04 PARTITION PENETRATION INSULATION SHALL NOT BE <br /> 'CANSUPPOrLT320Be STRAP <br /> USE TSP(NOT ESP)IF PRESSURE LARGE 32 X 32 30 X 30 MAXIMUM. WIRE IN CONTACT WITH PARTITION <br /> PROFILE INSIDE UNIT AT CONDENSATE —CONNECTION POINT POINT IS NOT AVAILABLE - I <br /> SPLIT SYSTEM CONDENSING UNIT ANGLE OR <br /> NEL FlRERATED PARTITON ICI <br /> TYPICAL CONDENSATE DRAIN PIPING m MOUNTING DETAIL n PIPING PENETRATION ROOF CAP — — <br /> 8.01 NOT TO SCALE 1.6A1 NOT TO SCALE M5.01 NOT TO SCALE <br /> \J k BOTTOM REINFORCEMENT eMMIll <br /> wham.(2)1',20 GA SHEET METAL <br /> HAN CARTi�I� _05/02/23 BOG PERMIT RESPONSE <br /> GER STRAPS AROUND ENTIRE . PIPE SLEEVE I.LARGER <br /> / ATTACH TO STRUCTURE AND AT ALL HANGER STRAP THAN PIPE AND INSULATION FIRESSPECIFIED UL LISTED —04/11/ �'23 ISSUE FOR PENT <br /> {G. CORNERS OF UNIT.EXTEND OUT AND (I'WIDE 20 GA)) OUTSIDE DIAMETER FIRE SANG MATERIAL <br /> UP AT AS'ANGIE FROBI UNITNo. Dote By Description <br /> \ SPECIFIED StInnP AND <br /> < „ P _I• <br /> I� WATERSTOP MASTIC <br /> Design Team <br /> • LOAD RATED FASTENER Design BOO <br /> I • <br /> 'firi <br /> Drown FPR <br /> 1 /ii"++11 ! or <br /> I�I Checked 21N <br /> / SMOKE OR FIRE <br /> IN-LINE FAN OR DAD.. A SECTION A-A SMOKE RATED PARTTIDN <br /> Pre Construction Number 21-22-22770 <br /> BOX(SEE DRAWINGS) 2813 NOTES: <br /> MAXIMUM 25-O TO 50'O FIRESAFING MATERIAL Construction Number XX-)C(-IODCXX <br /> NOTE FOR SEISMIC CATEGORY D: <br /> SHALL BE INSTAL A Fn IN <br /> 1. PROVIDE SEISMIC BRACING PER SMACNA SEISMIC RESTRAINT MANUAL.IBC AND ASCE Z. ACCORDANCE WITH THE Is..*Date 02/XX/23 <br /> Z NO BRACING REQUIRED FOR IP,.O AND UNITS<AOO POUNDS WITH FLEXIBLE MANUFACTURER'S UL <br /> CONNECTIONS ON DUCT AND/OR PIPING 8 INSTALLED AT A FT OR LESS ABOVE FLOOR. LISTED INSTALLATION <br /> 3. NO BRACING REQUIRED FOR 1p=1.0 AND UNITS<20 Pro TAR WITH FLEXIBLE INSTRUCTIONS(TYP). <br /> CONNECTIONS ON DUCT AND/OR PIPING. <br /> A. NO BRACING REQUIRED INDEPENDENT OF DUCTWORK FOR I0=10 OR'BAND /� UNINSULATED%PE <br /> UNITS LE POUNDS.WHERE UNIT ISHARD UN TO DUCT(FLEX DUCT SNOT 1 '�y ® - INSTALLATION IS SIMLAR. <br /> INSTALLED AT UNIT CONNECTIONS,AND NON BRACED PIPING IS PROVIDED WITH FLEX \V• <br /> CONNECTIONS FOR ADEQUATE FLEXIBILITY FOR DISPLACEMENT. _ <br /> 1C`Ol 11y G�}IFIWED '1 DETAILS <br /> SHEET <br /> -HVAC <br /> 12 SEISMIC TERMINAL UNIT INSTALLATION DETAIL n LOWER DUCT HANGER ATTACHMENTS ,. TYPICAL PIPE WALL SLEEVES <br /> MM.01 NOT TO SCALE M`1 NOT TO SCALE `001 NOT TO SCALE <br /> .JAI AAW/J <br /> FOR CITY USE <br /> M5.01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.