Laserfiche WebLink
I <br /> SITE PLAN NOTES <br /> 1. VERIFY EXISTING STRUCTURES AND ALL DIMENSIONS ON SITE. <br /> 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL <br /> PROPL( 'V PER FUR FOUNDATION SPECIALIST(MR)LEVEL SURVEY. <br /> 88 NE, "•'.'fir./._ •_ <br /> - 3. REFER TO STRUCTURAL CALCULATIONS PACKAGE BY L120 DATED MARCH 5, <br /> _i 2024,FOR ADDITIONAL INFORMATION.SPECIFICATIONS.AND "' <br /> REQUIREMENTS. <br /> 4. LEVEL SURVEY PER R&R PROPOSAL DATED DEC 11,2023.REFER TO <br /> STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND <br /> ADDITIONAL REQUIREMENTS FOR LEVEL SURVEY. <br /> 5. PARCEL DIMENSIONS APPROXIMATED BY SNOHOMISH COUNTY ASSESSOR <br /> ! I GIS MAPPING TOOLS 8 TAXSIFTER INCLUDING THE SELECTED PARCEL. <br /> \ PROPERTY DIMENSIONS ARE APPROXIMATE FOR REPRESENTATIVE <br /> PURPOSES ONLY.NOT TO SCALE.NOT TO BE USED FOR LEGAL PURPOSES <br /> OR IN PLACE OF A FIELD SURVEY. <br /> 6. SITE FEATURES AND SOME EXISTING STRUCTURES ON ADJACENT PARCELS III <br /> NOT SHOWN FOR CLARITY. III <br /> 7. SPECIAL INSPECTOR TO BE CONTINUOUSLY PRESENT DURING ALL Q } 6 <br /> PILE INSTALLATION AND LOAD TESTING. <br /> DH G <br /> 1- IZo <br /> v <br /> fJ <br /> rk ZZG <br /> Lrli <br /> 000 <br /> -+Z 1111,-- J <br /> IIIIT <br /> 2 n ��� <br /> I SITE PLAN LEGEND <br /> I <br /> i 0 EXISTING RESIDENCE STRUCTURE <br /> COVERED (E)RESIDENCE <br /> 7423 Lower Ridge Rd <br /> i ENTRY Everett.WA98203 EXISTING ADJACENT STRUCTURE <br /> (2)PILES q 7'OC MAX I AREA OF PROPOSED WORK <br /> ly - <br /> (E)a-CONCRETE STEM \ -- PROPERTY LINE <br /> WALL',TALL MN TWA AT 11 It:D <br /> �sREPLAN PERIMETER <br /> TFYi30PRpRTo i APPROXIMATE DIMENSION <br /> - WORK F CONCRETE WALL <br /> I AT PILE LOCATIONS IS <br /> 27'-0"' LESS TMAN r-T'TALL 3'OF CORNER MAXN 9 \ HELICAL PILE <br /> DIME <br /> ® '�4x4 ADJ.POST 2 P/z t <br /> 'a"-0• EASE WPPAD o C6X8.2 CHANNEL <br /> I' ; (2)PILES 7,'OC MAX ® 4x4 ADJ.POST BASE w/PAD 7423 Lower Ridge Rd <br /> • <br /> ti <br /> .,. .. ,,,,, w Everett,WA 98203 <br /> 23 E. <br /> ® t✓ \ <br /> o \ No S240102-1XR <br /> _ _______ PROPERTY L_IN_E H ! % LOCATE PLE WITHIN �B ip <br /> �-D" _J LOCATE PILE WITHIN <br /> C6x6Y CHANNEL (4)PILES 0 7'OC MAX 3'OF CORNER MAX <br /> 1'OF CORNER MAX 1 <br /> �/ } stab Palio PAM <br /> LOWER RIDGE RD / 11 2A <br /> _ 4 5 6 7 M RT <br /> 03/05/2024 <br /> PARCEL VIEW 12'-0"' z'-o" 12'-0"• <br /> N.T.S. <br /> • !21 PILExMAX <br /> LOCATE PEE WITHIN <br /> OF CORNER MAX <br /> 24' 1112'�10 <br /> 'I'' * '3:4 I 1R 2 % <br /> ITI PILES Ai e'MAX 12 -'9�U <br /> PILE SPACING&LOAD REOUIRMENTS TABLE 1.- are I t vz -3'+ >_ —o <br /> MIN O.C.SPACING.ft MIN VERTICAL CAPACITY.kips PROOF TESTING LOAD.kips 0i z F ez 13 0 <br /> PILE B PILE TYPE BTWN END 200%MIN VERTICAL CAPACITY LOCATION PARCEL NO. LOCATE PILE WITHIN a�w <br /> ALLOWABLE LOADING 1.OF CORNER MAX ;'•I 7 -1� a <br /> PILES OFFSET (MIN ULTIMATE CAPACITY) 00392000002002 1'---b"^24: ` <br /> 5 6 3t LOCATE PILE WITHM <br /> 1=1 HELICAL 7'-C' 3'-0' X 0 kip 'c 0 kip I PER PLAN I, 3'OF CORNER MAX <br /> LEGAL DESCRIPTION (4,PILES Q T OC MAX <br /> 4 <br /> NOTES: BEVERLY ACREAGE TRACTS BLK O=3"Helical Pile <br /> undatiOn <br /> a.MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE 000 D-02-LOT 20 LESS S 75FT o:.20 COI Crack m Pad with <br /> &.=20"Compoeilo with <br /> MANUFACTURER.THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING AH.4X4 Saddle Bracket <br /> CAPACITY LOADING,INCLUDING A SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM INSTALLATION TORQUE SHALL NOT OWNER NAME&ADDRESS T=6"Steel C Channeling <br /> EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY.MAXIMUM DIAMOND VENTURES LLC R&R LEVEL SURVEY <br /> INSTALLATION TORQUE RATING OF 8,300FT'LBS FOR A 2-718 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL <br /> THICKNESS PERESR-3750. 5406 HIGHLAND RD SEE STRUCTURAL CALCULATION PACKAGE FOR ADDITIONAL <br /> b.HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING,INC..IN ACCORDANCE WITH ESR-3750. EVERETT,WA 98203 <br /> c.PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART REQUIREMENTS <br /> OF THE ASSEMBLY. SITE PLAN rn <br /> d.MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. <br /> C- <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. w <br /> NOTE:L120'S SCOPE IS LIMITED TO THE PERIMETER SUPPORT SYSTEM/CONTINUOUS FOOTINGS.THE INTERIOR CRAWL SPACE SUPPORTED SYSTEM FOR THE FIRST FLOOR SHALL BE INSTALLED PER R&R. `" <br />