Laserfiche WebLink
. CONSTRUCTION SHALL CONFORM TO THE 2021 INTERNATIONAL BUILDING CODE (IBC) <br />AMENDED BY WASHINGTON STATE (WSBC), THE 2021 INTERNATIONAL RESIDENTIAL <br />DE (IRC) AS AMENDED BY WASHINGTON STATE AND/OR OTHER GOVERNING CODE, AS <br />]UIRED BY LOCAL JURISDICTION. <br />'RUCTURAL DRAWINGS INDICATE TYPICAL AND GENERAL CONSTRUCTION DETAILS. <br />HERE DETAILS ARE NOT REFERENCED AT LOCATIONS OF SIMILAR CONFIGURATION TO <br />:TAILS PROVIDED, SIMILAR DETAILS SHALL BE EMPLOYED. NOTES ON THE FOLLOWING <br />DIVIDUAL STRUCTURAL SHEETS SHALL TAKE PRECEDENCE OVER THESE GENERAL <br />'RUCTURAL NOTES. ANY SPECIFICATION CONFLICTS THAT MAY OCCUR WITHIN THIS <br />AN SET, THE CONTRACTOR SHALL DEFAULT TO THE MORE STRINGENT/ CONSERVATIVE <br />'ECIFICATION. <br />CONTRACTOR SHALL REVIEW THE CONSTRUCTION DOCUMENTS IN FULL FOR <br />URACY AND ADEQUACY AS RELATED TO SITE CONDITIONS. ANY DISCREPENCIES <br />ILL BE SUBMITTED TO THE FOR BEFORE PROCEEDING. <br />GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL DESIGN, PERMITTING AND <br />STRUCTION OF ALL UTILITIES INCLUDING PLUMBING, ELECTRICAL AND HVAC. ANY <br />UCTURAL MODIFICATIONS SHALL BE SUBMITTED TO THE FOR BEFORE PROCEEDING. <br />NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SUPERCEDE. THE GENERAL <br />)TRACTOR SHALL BE RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH <br />NINGS) AND SHALL REVIEW ALL DIMENSIONS AND THEIR ACCURACY IN ACCORDANCE <br />H ARCHITECTURAL DRAWINGS BEFORE CONSTRUCTION. <br />THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB <br />SITE, INCLUDING SOIL CONDITIONS (UNLESS SOILS REPORT EXISTS), AND CONDITIONS <br />RELATED TO EXISTING UTILITIES, EASEMENTS, AND/OR RIGHTS OF WAY. <br />THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS OF <br />CONSTRUCTION, WORKMANSHIP AND JOBSITE SAFETY. THE GENERAL CONTRACTOR IS <br />RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE STRUCTURE DURING <br />CONSTRUCTION AND SHALL PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL <br />PERMANENT CONNECTIONS AND STIFFENINGS HAVE BEEN INSTALLED. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIRED <br />INSPECTIONS WITH THE BUILDING DEPARTMENT. <br />AND ALL DISCREPANCIES BETWEEN THE STRUCTURAL DRAWINGS AND ANY OTHER <br />RELATED DRAWINGS, INCLUDING ARCHITECTURAL, CIVIL OR ANY OTHER <br />SULTANT DRAWINGS SHALL BE PROVIDED TO THE FOR BEFORE PROCEEDING. <br />DESIGN CRITERIA FOR SOILS REPORT INFORMATION, IF APPLICABLE. <br />WHERE SOILS REPORT NOT PROVIDED, 2000 PSF SOIL BEARING ASSUMED. ASSUMED <br />ALLOWABLE SOIL BEARING AND LATERAL PRESSURES SHALL BE FIELD -VERIFIED. <br />BEARING SOIL SHALL BE FREE OF ORGANIC MATERIAL. FOR SHALL BE NOTIFIED OF ANY <br />SOILS FOUND TO BE INADEQUATE TO REVIEW FOUNDATION ADEQUACY. SEE ADDITIONAL <br />SOILS NOTES ON RETAINING WALL DETAILS, IF APPLICABLE. <br />JGS SHALL BEAR ON FIRM, UNDISTURBED SOIL (OR CONTROLLED, COMPACTED <br />TURAL FILL) AT LEAST 18" BELOW EXISTING GRADE. ACTUAL ELEVATIONS OF <br />JGS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. OVEREXCAVATION <br />BE BACKFILLED USING LEAN CONCRETE (fD = 2000 PSI) OR STRUCTURAL BACKFILL. <br />ITRUCTURAL FILL SHOULD CONSIST OF PREDOMINATELY WELL -GRADED, GRANULAR <br />;OIL, FREE OF ORGANIC MATERIAL AND DEBRIS. FILL SHOULD BE PLACED IN MAXIMUM 8' <br />OOSE LIFTS AND COMPACTED TO A MINIMUM OF 95 PERCENT OF THE MAXIMUM DENSITY <br />,T OPTIMUM MOISTURE CONTENT DETERMINED BY ASTM D-1557 TEST PROCEDURES. <br />VFORMATION FOUND WITHIN SOILS REPORT AND/OR PROVIDED BY GEOTECHNICAL <br />NGINEER OR OTHER SOILS PROFESSIONAL, SHALL TAKE PRECEDENCE. ANY <br />IIGNIFICANT CONSTRUCTION FOUNDED ON STRUCTURAL FILL SHALL BE REVIEWED BY A <br />)EOTECHNICAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. <br />SPECIAL INSPECTIONS <br />SPECIAL INSPECTIONS SHALL BE PROVIDED AS REQUIRED BY THE BUILDING DEPARTMENT <br />AND IBC SECTION 1704. THE OWNER SHALL BE RESPONSIBLE FOR RETAINING ANY <br />SPECIAL INSPECTORS REQUIRED. ALL SPECIAL INSPECTION REPORTS SHALL BE <br />PROVIDED TO THE EORAS APPLICABLE. SEE CONCRETE SECTION FOR MORE ON SPECIAL <br />INSPECTIONS. <br />SPECIAL INSPECTIONS AND TESTS OF SOILS IBC 1705.E <br />VERIFICATION AND INSPECTION <br />FREQUENCY <br />REFERENCES <br />CONTINNOUS <br />PERIODIC <br />VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE <br />X <br />ADEQUATE TO ACHEIVE THE DESIGN BEARING CAPACITY <br />VERIFY EXCAVATIONS EXTEND TO PROPER DEPTH AND <br />X <br />HAVE REACHED PROPER MATERIAL <br />PERFORM CLASSIFICATION AND TESTING OF COMPACTED <br />X <br />FILL MATERIALS <br />VERIFY USE OF PROPER MATERIALS AND MATERIALS PER <br />GEOTECHNICAL REPORT. VERIFY DENSITIES AND LIFT <br />X <br />THICKNESSES DURING PLACEMENT AND COMPACTION OF <br />COMPACTED FILL. <br />PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE <br />SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED <br />X <br />PROPERLY. <br />WOOD FRAMING NOTES <br />GENERAL REQUIREMENTS <br />PROVIDE MINIMUM NAILING PER 2021 IBC TABLE 2304.10.2 (PROVIDED BELOW), UNLESS <br />NOTED OTHERWISE. ALL WOOD IN CONTACT WITH CONCRETE AND/OR EXPOSED TO <br />WEATHER SHALL BE PRESERVATIVE -TREATED BY AN APPROVED METHOD. ALL CUTS, <br />NOTCHES AND EXPOSED ENDS TO BE RE -TREATED. DO NOT NOTCH, BEVEL OR DRILL <br />STRUCTURAL MEMBERS, EXCEPTAS ALLOWED BY SECTIONS 2308.4.2.4 AND 2308.7.4, OR <br />AS ALLOWED ELSEWHERE WITHIN THIS PLAN SET. <br />FRAMING LUMBER <br />STRUCTURAL LUMBER SHALL ADHERE TO THE FOLLOWING TABLE: <br />MEMBER <br />GRADING <br />f, <br />f„ <br />fCll <br />fc� <br />(PSI) <br />(PSI) <br />(PSI) <br />(PSI) <br />STUDS, SAWN FLOOR JOISTS, <br />HF#2 OR BETTER <br />SAWN RAFTERS (2x LUMBER) <br />(HEM FIR #2 <br />850 <br />150 <br />1300 <br />405 <br />POSTS, BEAMS, HEADERS <br />DF#2 OR BETTER <br />4x LUMBER AND GREATER <br />DOUG FIR #2 <br />900 <br />180 <br />1350 <br />625 <br />LVL- LAMINATED VENEER <br />LUMBER (FLUSH BEAMS, <br />1.9E <br />2600 <br />285 <br />2510 <br />760 <br />COLLECTORS, RAFTERS <br />GLB - GLUED -LAMINATED <br />24F-V4 - TYPICAL <br />24DDI <br />1850(-) <br />BEAMS(DROR,HEADERS)EXPOSED, <br />24F-V8-CANTILEVERED <br />24001 <br />265 <br />1650 <br />650 <br />EXTERIOR, HEADERS <br />2400(-) <br />PSL- PARALLEL STRAND <br />LUMBER (FLUSH BEAMS, <br />2.0E <br />2900 <br />290 <br />2900 <br />750 <br />HEADERS <br />LSL- LAMINATED STRAND <br />LUMBER (FLUSH BEAMS, <br />1.55E <br />2325 <br />310 <br />2050 <br />800 <br />COLLECTORS, RIMS) <br />2x TIMBER SHALL BE KILN DRIED. GRADES SHALL CONFORM TO WWPA GRADING RULES <br />FOR WESTERN LUMBER", LATEST EDITION. <br />STALL MINIMUM 1/2° COX PLYWOOD (32/16) OR 7/16" OSB SHEATHING. NAIL ALL <br />IPPORTED EDGES AND BOUNDARIES WITH 8d AT 6" O.C, AND INTERIOR SUPPORTS WITH <br />AT 12" O.C.; BLOCKING NOT REQUIRED, UNO. SEE ROOF FRAMING PLAN(S) FOR <br />OITIONAL INFORMATION. <br />LLL MINIMUM 23132" T&G STURD-I-FLOOR SHEATHING. GLUE AND NAIL ALL <br />ORTED EDGES AND BOUNDARIES WITH 10d AT 6" O.C., AND INTERIOR SUPPORTS <br />10d AT 12" O.C.; BLOCKING NOT REQUIRED, UNO. SEE FLOOR FRAMING PLAN(S) FOR <br />'ZONAL INFORMATION. <br />BRICATED WOOD TRUSSES TO BE DESIGNED PER IBC 2303.4.1.1 TO CARRY LOADS <br />IN THE DESIGN CRITERIA SECTION AND ANY ADDITIONAL POINT LOADS, UNIFORM <br />OR DRAG STRUT FORCES PROVIDED ON THE ROOF FRAMING PLAN(S). <br />3S DESIGN DRAWINGS AND DOCUMENT SUBMITTAL SHALL INCLUDE STRESS ANLYSIS <br />DEPICTION OF EACH TRUSS TYPE, AND SHALL INCLUDE A TRUSS LAYOUT, TRUSS <br />_YSIS, LAYOUT AND INSTALLATION DOCUMENTS SHALL BEAR THE SEAL AND <br />IATURE OF AN ENGINEER LICENSED IN THE STATE OF WASHINGTON. APPROVED <br />3S DOCUMENTS SHALL REMAIN ON THE JOB SITE THROUGHOUT CONSTRUCTION. <br />ABRICATED TRUSSES SHALL NOT BE NOTCHED, DRILLED, CUT, SPLICED OR <br />RWISE ALTERED WITHOUT WRITTEN APPROVAL FROM THE TRUSS DESIGN <br />IEER. ALTERATIONS RESULTING IN THE ADDITION OF LOADS TO ANY MEMBER (E.G. <br />EQUIPMENT, PIPING, ETC.) SHALL NOT BE PROHIBITED WITHOUT WRITTEN <br />)VAL FROM THE TRUSS DESIGN ENGINEER. <br />UNLESS NOTED OTHERWISE, ALL TRUSSES SHALL BE SPACED AT 24" O.C. AND HAVE <br />SIMPSON H1 CLIPS AT EXTERIOR WALLS. GABLE TRUSSES SHALL HAVE A35 CLIPS @ 24" <br />O.C., UNO. <br />THE GENERAL CONTRACTOR SHALL PROVIDE THE FOR WITH A COPY OF THE APPROVED <br />TRUSS DOCUMENTS FOR REVIEW. IF THE TRUSS DOCUMENTS WERE DEVELOPED <br />SUBSEQUENT TO THE ISSUANCE OF THIS PLAN SET, THE TRUSS ANALYSES MAY RESULT <br />REVISIONS TO THE BEAM CALCULATIONS ASSOCIATED WITH THIS PLAN SET. <br />FASTENERS <br />THE LATEST SIMPSON STRONG -TIE COMPANY, INC. PRODUCTS WERE USED AS A BASIS <br />FOR THIS PROJECT. CONNECTORS BY ALTERNATE MANUFACTURERS MAY BE <br />SUBSTITUTED PROVIDED THEY HAVE CURRENT ICC-ESR/IAPMO-ER APPROVAL FOR <br />EQUIVALENT OR GREATER LOAD CAPACITIES. ALL FASTENERS AND CONNECTORS SHALL <br />BE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. <br />NAILS AND STAPLES TO CONFORM TO IBC 2303.6 "NAILS AND STAPLES." ALL NAILING TO <br />BE PROVIDED PER TABLE 2304.10.2 (PROVIDED BELOW). ALL NAILS SPECIFIED SHALL BE <br />COMMON, UNO. <br />COMMON NAILS <br />SIZE LENGTH DIAMETER <br />8d T/,' 0.131" <br />10d 3" 0.148" <br />l6d 3'/,' 0.162" <br />16d SINKER 314" 0,148" <br />LETE SHALL CONSIST OF PORTLAND CEMENT ASTM C-150 TYPE II OR TYPE I AND <br />BE READY -MIXED PER ASTM C-94, MAXIMUM SLUMP 5". MINIMUM 5'/, SACKS OF <br />IT PER CUBIC YARD OF CONCRETE. SEGREGATION OF MATERIALS TO BE <br />MINIMUM SPECIFIED COMPRESSIVE STRENGTH (fGAT 28 DAYS) ACI 318-14 <br />LOCATION/USE <br />fD (PSI) <br />SPECIAL INSPECTION & <br />TESTING REQUIRED <br />FOOTING PADS & FOUNDATIONS NOT <br />2500 <br />NOT REQUIRED <br />EXPOSED TO WEATHER <br />PORCHES, PATIOS, DRIVEWAYS <br />3000 <br />NOT REQUIRED <br />GARAGE SLABS <br />FOUNDATION STEM WALLS AND <br />2500 <br />NOT REQUIRED <br />INTERIOR SLABS ON GRADE <br />REINFORCEMENT STEEL <br />REINFORCING STEEL #5 BARS AND LARGER SHALL BE GRADE 60 DEFORMED BARS, AND #3 <br />AND #4 BARS SHALL BE GRADE 40, IN ACCORDANCE WITH ASTM A-615. LAP SPLICES 32 <br />BAR DIAMETERS OR 18" MIN. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 AND <br />SHALL BE 6X6 — W1.4 X W1.4. LAP ONE FULL MESH AT SPLICES. SEE CONCRETE DETAILS <br />FOR MORE INFORMATION. <br />CONCRETE COVER REQUIREMENTS <br />REINFORCING BAR LOCATION <br />MIN CONCRETE COVER <br />UNFORMED SURFACES CAST AGAINST AND <br />3„ <br />PERMANENTLY EXPOSED TO EARTH <br />FORMED SURFACES EXPOSED TO EARTH OR WEATHER <br />2 <br />#6 BARS AND LARGER <br />FORMED SURFACES EXPOSED TO EARTH OR WEATHER <br />11/2" <br />#5 BARS AND SMALLER) <br />COLUMNS AND BEAMS WITH BARS ENCLOSED IN <br />11/2" <br />STIRRUPS, TIES OR SPIRAL REINFORCEMENT <br />SLABS, JOISTS AND INTERIOR FACES OF WALLS <br />3/4 <br />(#5 BARS AND SMALLER) <br />SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION <br />IBC 1705.3 <br />FREQUENCY <br />VERIFICATION AND INSPECTION <br />REFERENCES <br />CONTINUOUSI PERIODIC <br />INSPECT REINFORCEMENT AND VERIFY PLACEMENT <br />X <br />ACI 318: CH. 20, <br />25.2-3, 26,6.1-3 <br />INSPECT ANCHORS CAST IN CONCRETE <br />X <br />ACI 318:1782 <br />IBC 1904A-2, <br />VERIFY REQUIRED DESIGN MIX <br />X <br />ACI 318: CH. 19, <br />26.4.3-4 <br />PRIOR TO CONCRETE PLACEMENT, FABRICATE <br />SPECIMENS FOR STRENTH TESTS, PERFORM SLUMP AND <br />X <br />ASTM C172, C31 <br />AIR CONTENT TESTS AND DETERMINE TEMPERATURE OF <br />ACI 318'. 265,26.12 <br />CONCRETE <br />INSPECT CONCRETE PLACEMENT FOR PROPER <br />X <br />ACI 318. 26.5 <br />APPLICATION TECHNIQUES <br />VERIFY MAINTENANCE OF SPECIFIED CURING <br />X <br />ACI 318: 26.5.3-5 <br />TEMPERATURE AND TECHNIQUES <br />INSPECT FORMWORK FOR SHAPE, LOCATION AND <br />X <br />pC1318'.2fi.7 t.1.2(b) <br />DIMENSIONS OF THE CONCRETE BEING POURED <br />IMINAL WIND SPEED — 85 MPH RISK CATEGORY II <br />TIMATE WIND SPEED — 110 MPH IMPORTANCE, I = 1.0 <br />NO EXPOSURE, B Kn= 1.00 <br />VALENT LATERAL FORCE PROCEDURE <br />IRTANCE, IS = 1.0 <br />S, = 1.33 <br />CLASS, D <br />S, = 0.47 <br />MIC DESIGN CAT. D <br />S = 1.06 <br />FORCE RES. SYS, A.15. <br />So = NA <br />GIN BASE SHEAR = 36221 Ibs <br />CA, = 0.16 <br />CATEGORY II <br />R = 6.5 <br />LOADS: <br />25 (SNOW) <br />IR 40 PSF <br />;S 60 PSF <br />NO SPECIAL INSPECTIONS ARE REQUIRED. VERIFY INSPECTIONS <br />H AUTHORITY HAVING JURISDICTION. <br />:H EOR: NA <br />'#: NA <br />SOILS REPORT NOT PROVIDED, 2000 PSF SOIL BEARING ASSUMED. <br />SEISMIC AND WIND ANALYSIS (LATERAL DESIGN) <br />VERTICAL LOAD ANALYSIS (GRAVITY DESIGN) <br />FOUNDATION DESIGNIVERIFICATION <br />LATERAL DRAFTING <br />LATERAL DETAILING <br />SPECIAL INSPECTIONS REQUIRED FOR STRUCTURAL <br />WOOD PER IBC 1705.12.2. <br />PERIODIC SPECIAL INSPECTION SHALL BE REQUIRED <br />FOR NAILING, ANCHORING, AND OTHER FASTENING <br />OF ELEMENTS OF THE SEISMIC FORCE -RESISTING <br />SYSTEM, INCLUDING WOOD SHEAR WALLS, WOOD �1 DIAPHRAGMS, DRAG STRUTS, BRACES, SHEAR PANELS <br />AND HOLD-DOWNS. <br />SPECIAL INSPECTIONS ARE NOT REQUIRED WHEN THE <br />FASTENER SPACING IS MORE THAN 4INCHES. <br />MINIMUM FASTENING SCHEDULE (UNO) (PER 2021 IBC TABLE 2304.10.2) <br />NO. <br />CONNECTION NAILING, LOCATION (LINO) <br />1 <br />BLOCKING BETWEEN JOIST/RAFTER OR TRUSSES TO TOP PLATE OR OTHER FRAMINGABOVE <br />(3). Rd, TOENAIL EACH END <br />2 <br />BLOCKING BETWEEN JOIST/RAFTER OR TRUSSES NOT AT THE WALL TOP PLATE, TO RAFTER OR TRUSS <br />(2) 8d, TOENAIL EACH END <br />3 <br />FLAT BLOCKING TO TRUSS AND WEB FILLER <br />16d FACE NAIL <br />4 <br />JOISTS TO TOP PLATE OR GIRDER <br />(3) Rd, TOENAIL <br />5 <br />CEILING JOIST NOT ATTACHED TO PARALLEL RAFTER LAPS OVER PARTITIONS (NO THRUST) <br />(3). 16d <br />6 <br />COLLAR TIE TO JOIST/RAFTER <br />(3) 1Ed <br />7 <br />ROOF TRUSS TO TOP PLATE <br />(3) 10d, TOENAIL <br />8 <br />ROOF JOIST/RAFTER TO RIDGE VALLEY OR HIP RAFTERS; OR ROOF RAFTERTO 2" RIDGE BEAM <br />(2) 16d, END NAIL <br />9 <br />STUD TO STUD (NOT AT SHEAR WALLS) <br />16d @ 24" O.C., FACE NAIL <br />10 1 CONTINUOUS HEADER TO STUD <br />(4) Ed, TOENAIL <br />11 <br />TOP PLATE TO TOP PLATE, AT END JOINTS <br />(8) 16d, EACH SIDE OF END JOINT, FACE NAIL (MINIMUM 24- LAP SPLICE LENGTH EACH SIDE OF END JOINT <br />12 <br />SILL PLATE TO JOIST, RIM JOIST OR BLOCKING (NOT AT BRACED WALL PANELS) <br />16d @ 16" O.C., FACE NAIL <br />13 <br />SILL PLATE TO JOIST, RIM JOIST OR BLOCKING AT BRACED WALL PANELS <br />(3) 16d @ 16" O.C., FACE NAIL <br />14 <br />STUD TO SILL PLATE <br />(4) BE, TOENAIL OR (2) 16d, END NAIL - <br />is <br />TOP PLATE TO STUD <br />(2) 16d, END NAIL <br />16 <br />TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS <br />(2) 16d, FACE NAIL <br />17 <br />1" BRACE TO EACH STUD AND PLATE <br />(2) BE, FACE NAIL <br />18 <br />1 " x 6" SHEATHING OR LESS TO EACH BEARING <br />(2) Ed, FACE NAIL <br />19 <br />1 " x 8" AND WIDER SHEATHING TO EACH BEARING <br />(3) 8d, FACE NAIL <br />20 <br />JOIST TO SILL, TOP PLATE OR GIRDER <br />(3) 8d, TOENAIL <br />21 <br />RIM JOIST, OR BLOCKING TO TOP PLATE, SILL OR OTHER FRAMING BELOW <br />Ed @ 6" O.C., TOENAIL <br />22 <br />1" x 6" SUBFLOOR OR LESS TO EACH LOST <br />(2) Ed, FACE NAIL <br />23 <br />2" SUBFLOOR TO JOIST OR GIRDER <br />(2) 16d, BLIND AND FACE NAIL <br />24 <br />2" PLANKS (PLANK & BEAM - FLOOR & ROOF) <br />(2) 16d, EACH BEARING, FACE NAIL <br />25 <br />BUILT-UP GIRDERS AND BEAMS, 2" LUMBER LAYERS <br />20d @ 32" O.C., FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES AND (2) 20d AT ENDS OF EACH SPLICE <br />26 <br />LEDGER STRIP SUPPORTING JOISTS OR RAFTERS <br />(3). 16d, EACH JOIST OR RAFTER, FACE NAIL <br />27 <br />JOIST TO RIM JOIST <br />(3) 16d, END NAIL <br />28 <br />BRIDGING OR BLOCKING TO JOIST <br />(2) 8d, EACH END, TOENAIL <br />-USE (4) 16d END NAIL STUDS TO TOP AND SILL PLATES AT 2AC STUDS <br />0 <br />o <br />rn <br />_ <br />W0 <br />Q o <br />�U <br />U) <br />FW- N <br />y :D <br />L <br />VJ <br />z <br />n` <br />ll/ <br />>> <br />w <br />� <br />LIU <br />m <br />N N <br />Fo <br />M <br />u <br />N <br />W <br />(� <br />w <br />QJ <br />F ~ <br />IL <br />m <br />0 <br />} <br />N <br />UPSTATE STAMP <br />w <br />.G. <br />F <br />fro <br />PST afC 442 <br />SS/ONAL <br />ECG <br />64SILO24 <br />Z <br />U) <br />w 00 <br />pZP <br />it Z <br />::) Z <br />I- ►— 0 <br />U0U <br />Z <br />� � <br />U <br />U) <br />W <br />�200 <br />m <br />M <br />— > C) <br />OZ��cq <br />Op <br />Cr) <br />W <br />Q o <br />ZF- <br />w� <br />0>-Q— <br />(n00 <br />W <br />Lu <br />H Z LU <br />ti <br />OfM <br />J p i <br />co <br />-- <br />n <br />W <br />c) <br />3:m <br />W <br />Z <br />UPSTATE JOBR <br />1806 <br />DRAAN DY. <br />CHECKED BY: <br />JBG <br />amg <br />REVISION DATE: <br />DESCRIPTION: <br />611312024 <br />VERSION 1 <br />APPROVALS <br />so <br />