Laserfiche WebLink
W2ITRN DIhBUOIG ON TIIWi ORAN'NS'JW. L NAVE PRK.®NIGE OVER SCALED DIMBbbN5. <br />OONTR Tm SHALL VERIFY All Dlt-EN510N5, C ITIOI,61 M.:H2fNmiI TO THE NOW <br />BORE FROOEEDIN . TIE OW W5T ME NOTIFIED OF ANY VARIATION5 FROM THE <br />DIMEI OW AND/OR OONDITIOI 9140HN ON THEME DRAHN ANT 5W'H VARIATION SHALL SE <br />RE50LVED BY TIE om H PRIOR TO �IN NITH THE Now, m TIE CONI rm 9lKL <br />AOOEPT Fl RE5P NBILITT FOR TE OOST TO REOTIFY 5AME. <br />GARAGE NOTES. <br />I. &ARAGE/LIVIN6 SEPARATION, USE <br />we" TYPE 'X' GNIB AT CEILIN&/WALL. <br />WRAP POSTS AND DEAMS. <br />2. INSULATE ALL WARM WALLS AND <br />CeILIN&. <br />5. DOOR MI &^RAGE ANO RESIDENCE <br />SHALL BE 1-5/e' MINIMUM THICK SOLID WOOD <br />OR STEEL WITH SOLID OR HONEYCOMB CORE <br />OR 20 MINUTE FIRE RAT® EQUIPPED WITH A <br />SELF CLOSING DEVICE. <br />PLAN I-15B <br />on_nn <br />Loq <br />PLAN I'M <br />1n's" <br />NOTES: <br />LEGEND: <br />ALL EXTERIOR WARM WALLS TO BE <br />------ BEARING ABODE <br />2 X 6 STUDS o 16' O.O. TYPICAL. <br />------ <br />ALL INTERIOR WALLS TO EfE <br />FLOOR LINE ABCNE <br />2 X 4 STUDS ® 16" O.O. TYPICAL. <br />ALL HEADERS TO DE 4XIO DFa2 <br />PT. LD. p, POINT LOAD ASI <br />ABV. <br />UNLESS NOTED OTHERWISE. <br />=J� MULTIPLE 2 STUDS <br />®POINT LOAD <br />FUR -OUT HEADERS TO MATCH 2 X b <br />WALLS. <br />5MOKE DTECTOR <br />E <br />SOLID BUNDER EARING ALL B <br />LOCKING <br />Q 1OV INTERCONNEGTPA <br />W/ BATTERY BACK-UP. <br />WALLS <br />PER IRG 514 <br />TJB/SHOWER UNITS SHALL HAVE FIRE <br />BLOCKING BETWEEN WALL STIRS AND <br />O CARBON MONOXIDE DETECTOR <br />WATERPROOF SURROUNDS TO +12" <br />PER IRG 3I5 <br />FROM DRAIN. GLAZIN&, INCLUDING <br />WINDOWS WITHIN +12" OF OMAIN, <br />O HEAT DETECTOR <br />SHALL BE SAFTE:Y &LASS. SHOWER <br />FLOW 19 LIMITED TO I.75 OAL/MIN. <br />EXHAUST FANS LARGER THAN SOGFM MAY BE <br />CONNECTED TO 4" SMOOTH WALL VENT PIPE <br />LATERAL NOTES: <br />IF RUNS DO NOT FXCAMP 20' IN LEN&TH. <br />THE MINIMUM 5IzE OF FrEx DucT IS s" <br />DIAMETER WITH MAX MUM RUN of 15' <br />LATERAL DESIGN PREPARED BY <br />UPSTATE ENGINEERING. 5EE --SHEETS <br />COMBUSTION AIR REQUIRED FOR ALL <br />FOR ADDITIONAL NOTES AND DETAILS <br />FUEL BURNINS APPLIANCES <br />PLAN 1158 <br />on'_n" <br />SMOKE DETECTORS SHALL BE INSTALLED <br />NOT LESS THAN 5 FEET HORIZONTALLY <br />FROM THE DOOR OR OPENING OF A <br />BATHROOM THAT CONTAINS A TlB <br />OR SHOVER PER R514 <br />IONI ATION r2Mp s A 6e1..i5, <br />SHALL NOT BE INSTALLED LES5 THAN <br />20' HORIZONTALLY FROM A PERMANENTLY <br />INSTALLED GOOKIN& APPLIANCE. <br />IONIZATION SMOKE ALARMS WITH AN <br />ALARM SILENCING SWITCH SHALL NOT <br />DE INSTALLED LE55 THAN 10' HORIZONTALLY <br />FROM A PERMANENTLY INSTALLED COOKING <br />APPLIANCE. <br />TO ELECTRIC SMOKE ALARMS: <br />SHALL NOT SE INSTALLED LESS THAN 6' <br />HORIZONTALLY FROM A PERMANENTLY <br />INSTALLED COOKINS APPLIANCE PER RM4 <br />PLAN I18 <br />SEE 5HEE7 R4J <br />FOR RIGHT SIDE <br />OF BUILDINO <br />LC TrS� Fl—o CS� 51 <br />5EE GENERAL NOTES SCALE. 1/4' . V-0" <br />I�eTI <br />\ RE619TERf9 <br />PRCHITEGT <br />I AT OF WA=MIN9TON <br />F <br />VJ <br />� <br />�! <br />H <br />U <br />7 <br />x <br />m <br />r <br />11.1 <br />Q <br />O <br />O <br />Z <br />� <br />� <br />O <br />Z <br />O <br />to <br />li- <br />ILA <br />`p <br />Q <br />i <br />IL/ <br />� <br />L <br />L <br />Q <br />date: 10-6-2a <br />permit: <br />raVTzlo195• <br />5-20-24 <br />drawn by <br />ch®cic®d by: <br />I -MD <br />MWJ <br />SF -FEET <br />/ `4 <br />o>= <br />A 10 <br />