My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9930 19TH AVE SE 2024-10-11
>
Address Records
>
19TH AVE SE
>
9930
>
9930 19TH AVE SE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2024 1:42:25 PM
Creation date
9/30/2024 9:57:02 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
9930
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M <br /> GENERAL NOTES: <br /> FIRE ALARM SYMBOL LEGEND <br /> _ 1. SCOPE OF WORK: THIS PROJECT SHALL INCLUDE THE INSTALLATION OF AN AES <br /> NOTE. .BYNB(Ds waY NOT BE USED DN THIS BBaEDT .� ' ` COMMUNICATOR TO AN EXISTING RADIONICS D7212 PANEL. <br /> SYMBOL DESCRIPTION MANUF. & PART # MOUNTING MOUNT IN OTY �- '* 416 M 2. THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO THE ARCHITECTURAL DRAWINGS <br /> FOR EXACT DIMENSIONS. <br /> FACP FIRE ALARM CONTROL PANEL RADIONICS-D7212 EXISTING EXISTING - .�,�. ;: 1•""' o� <br /> COM FIRE ALARM COMMUNICATOR AES-7707-P-88-ULP-M WALL-TOP®66" CABINET INCLUDED t f;;: 3. INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND ALL OTHER APPLICABLE o 9z <br /> Ki CODES AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. a x <br /> ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION r �nouss�© <br /> E EXISTING AWG I AMERICAN WIRE GAUGE LIS001 OR M01 *� 4. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY w <br /> G WITH GUARD TWP TWISTED PAIR (I -DENOTES LOOP 4) ' DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING c <br /> P PENDENT MOUNT TWSP TWISTED SHIELDED PAIR (s a u-I>ENDEEs SENSOR oHuolwlE f) 4»,3L;�AN r F , ! CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA o <br /> R RESIDENTIAL 110V FPLP FIRE POWER LIMITED PLENUM 1- 16 2 TWP ,, v :, t`d.v ="` SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS W <br /> S SOUNDER BASE FPLR FIRE POWER LIMITED RISER wRE YPE ABBRLVPTED ! , �' LONG AS NO 11 OV OR HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. ti <br /> WP WEATHERPROOF O.SVER CWM T, <br /> EOL END OF LINE RESISTOR 2 r ���sizE y Y 5. FIRE RATINGS SHALL BE MAINTAINED FOR ALL PENETRATIONS THROUGH FIRE-RATED z <br /> OF CV3LES(IF OMRIED ""�' �"�� <br /> EOLR END OF LINE RELAY 15 30 �NLY 1 CABLE NEEDED) ,." $ _ CONSTRUCTION. y <br /> > o <br /> 6. POWER FOR ALL FIRE ALARM PANELS AND FIRE ALARM POWER SUPPLIES MUST BE rc <br /> ! e PROVIDED BY A DEDICATED AC BRANCH CIRCUIT. THE LOCATION OF THE BRANCH <br /> 1 s_ CIRCUIT BREAKER SHALL BE PERMANENTLY IDENTIFIED AT THE CONTROL UNIT, <br /> MECHANICALLY PROTECTED, ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL AND Z co <br /> a a g i SHALL BE RED AND LABELED FIRE ALARM CIRCUIT CONTROL" IN ACCORDANCE O co <br /> WITH NFPA 72. ELECTRICAL CONTRACTOR SHALL PERFORM LOAD CALCULATIONS TO <br /> o < 5z o 3 DETERMINE SIZE OF WIRING AND BREAKERS FOR ALL FIRE ALARM AC BRANCH Co <br /> a z o N x CIRCUITS BASED ON THE INFORMATION PROVIDED IN THE BATTERY CALCULATIONS � <br /> OPERATIONS a z z ��' FOR THE FIRE ALARM EQUIPMENT. <br /> MATRIX 4 LL Gq �y 7. POWER-LIMITED AND NONPOWER-LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED <br /> a m a �' r IN CABINET. ALL POWER-LIMITED CIRCUIT WIRING MUST REMAIN AT LEAST 0.25" <br /> EXISTING SYSTEM OPERATIONS SHALL y " < x AWAY FROM ANY NONPOWER-LIMITED CIRCUIT WIRING. FURTHERMORE, ALL Z <br /> REMAIN,FIELD VERIFY ACTUAL SYSTEM o y z o y o o 1 I 1 :(�; POWER-LIMITED AND NONPOWER-LIMITED CIRCUIT WIRING MUST ENTER AND EXIT <br /> OPERATIONS z s2 ' <br /> o a w w m w m ��' THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATE CONDUITS. a <br /> U c a c c a F < s w L 3u'I s .1, t: - LL E <br /> 8. WHEN UTILIZING CLASS "A" CIRCUITS, SEPARATE OUTGOING AND RETURN d <br /> a r w 00- <br /> ww CONDUCTORS OF CLASS "A" CIRCUITS BY A MINIMUM OF 12" WHERE RUN QVERTICALLY AND 48" WHERE RUN HORIZONTALLY. V) znFIRE ALARM INPUT Y c a a a a vi s z J v� <br /> 9. WHEN UTILIZING SHIELDED CABLE TIE SHIELDS THROUGH AND INSULATE AT EACH <br /> SMOKE DETECTORS • • • • • • • • • JUNCTION BOX. INSULATE AND TAPE BACK AT END. <br /> HEAT DETECTORS • • • • • • • • N VICINITY MAP <br /> SCHEMATIC:NOT TO SCALE 10. ALL FIRE ALARM CABLING SHALL BE ACCEPTABLE TO THE FIRE ALARM EQUIPMENT F, <br /> KITCHEN HOOD • • • • • • • • MANUFACTURER FOR THE INTENDED PURPOSE. CABLES USED IN VERTICAL RUNS x <br /> SHALL BE TYPE FPLP OR FPLR. CABLE SPLICES OR TERMINATIONS SHALL BE MADE <br /> PULL STATIONS • • • • • • • • IN LISTED FITTINGS, BOXES, ENCLOSURES, FIRE ALARM DEVICES, OR UTILIZATION <br /> WATERA OW SWITCHES • • • • • • • • EQUIPMENT. WHERE INSTALLED EXPOSED, CABLES SHALL BE ADEQUATELY <br /> VALVE SUPERVISORY SWITCHES • • • • SUPPORTED AND INSTALLED IN SUCH A WAY THAT MAXIMUM PROTECTION AGAINST c <br /> PHYSICAL DAMAGE IS AFFORDED BY BUILDING CONSTRUCTION. WHERE LOCATED <br /> DUCT DETECTORS • • • • • • WITHIN 7 FT OF THE FLOOR, CABLES SHALL BE SECURELY FASTENED IN AN <br /> FIRE ALARM AC POWER FNL • • • • APPROVED MANNER AT INTERVALS OF NOT MORE THAN 18 IN. <br /> FIRE ALARM LOW BATTERY • • • • 11. SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION <br /> OPEN CIRCUIT • • • • CLEAN-UP IS COMPLETED AND FINAL. <br /> A/C SUPPLY OR <br /> GROUND FAULT • • • • RETURN DIFFUSER PENDANT MOUNTED NOTE:MEASUREMENTS 12. LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL <br /> NAC SHORT CIRCUIT • • • • CEILING-MOUNTED II AUDIBLE/VISUAL SHOWN ARE TO THE DIFFUSERS. WALL—MOUNTED SMOKE DETECTORS SHALL BE LOCATED A MAXIMUM OF <br /> 4"MIN HEAT DETECTOR �7 CEILING APPLIANCES CLOSEST POINT OF 12" FROM CEILING. <br /> LOSS OF AC TO BUILDING • • • • • DETECTOR <br /> 4"MIN 6"MIN. ---1 36"MIN• 13. PROVIDE SYNCHRONIZATION OF ALL VISUAL NOTIFICATION APPLIANCE CIRCUITS. <br /> 2"MAX <br /> 12`MAX AUDIBLE/VISUAL AUDIBLE-ONLY REMOTE ALARM PROVIDE ALL REQUIRED SYNC MODULES. PROVIDE AMULTI-SYNC MODE SLAVE <br /> EVER AND/OR VISUAL CEILING MOUNTED CEILING MOUNTED <br /> / APPLIANCES INDICATOR SMOKE/HEAT AUDIBLE/VISUAL CONNECTION BETWEEN ALL SYNC MODULES. <br /> HERE ONLY APPLIANCE O DETECTOR APPLIANCES <br /> WALL-MOUNTED 14. VERIFY ALL FIELD SELECTABLE AUDIBILITY SETTINGS OF NOTIFICATION APPLIANCES <br /> WALL-MOUNTED SMOKE DETECTOR WITH FIRE ALARM CONTRACTOR. <br /> HEAT DETECTOR DOOR WIDTH <br /> LESS 3!-4 15. UPON COMPLETION OF THE FIRE ALARM SYSTEM INSTALLATION AND PROGRAMMING, <br /> 6" THE INSTALLING CONTRACTOR SHALL PERFORM FINAL TESTING OF THE ENTIRE <br /> FSA MAGNETIC <br /> Rd 30'MAX SYSTEM, PER ALL APPLICABLE CODES, AND SHALL COORDINATE AND PERFORM A a <br /> FRCP SYSTEM HOLDER DOOR AFF FINAL FIRE ALARM SYSTEM INSPECTION. co <br /> RECORDS. SIDE WALL W Q Z <br /> 7 1�1 <br /> DOCUMENTS TO LOWEST WHERE CEILING 10A MAX 3oAFTMAx 16. PROVIDE OFF-SITE MONITORING AS REQUIRED BY THE INTERNATIONAL FIRE CODE, (V Q <br /> G PART of LENS HEIGHT ALLOWS 5.MAX SECTION 907.6.E AND THE LOCAL AUTHORITY HAVING JURISDICTION. 0 J <br /> 66"TO 66"TO 66"TO FROM EXIT FINISHED 17. INSTALLING CONTRACTOR SHALL, PHYSICALLY, LABEL ALL INITIATING DEVICES AND LLB Wa. <br /> FACU TOP OF TOP OF TOP OF t <br /> WALL NOTIFICATION APPLIANCE CIRCUIT END OF LINE (WHEN WIRING CLASS "B". THESED7212 FSA FACP CABINET LABELS SHALL BE IN PLACE PRIOR TO START-UP AND TESTING. ) W Q M <br /> ZONE-1 EXIS ING INITIATING:REMAINING THE SAME MAPUL 48" Lu N <br /> FINISHED STATION 18. ROOMS CONTAINING CONTROLS FOR AIR-CONDITIONING SYSTEMS, SPRINKLER RISERS > = LL <br /> AES FLooR AND VALVES OR OTHER FIRE DETECTION, SUPPRESSION OR CONTROL ELEMENTS Lu Q <br /> Z INCH. LETTERS SHALL CONTRAST WITH BACKGROUND.-2 EXISTING INITIATING:REMAINING THE SAME SHALL BE IDENTIFIED WITH PERMANENTLY MOUNTED SIGNS WITH LETTERING NOT J <br /> 707-P-88-UL o0o LESS THAN 2 INCHES TALL WITH A PRINCIPAL STROKE OF NOT LESS THAN 3/8 V) T W Q <br /> a <br /> IRTEALARM ZONE-3 EXISTING INITIATING:REMAINING THE SAME FIRE ALARM DEVICE MOUNTING HEIGHTS M R WN <br /> C MUNICATOR SCALE:NOT TO SCALE W I.I. <br /> ZONE-4 EXISTING INTMTING:REMAINING THE SAME <br /> W W <br /> BnTTERv <br /> ALA BLE <br /> SUPERVISORY <br /> INTELLITAP NAC-1 EXISTING NOTIFICATION:REMAINING THE SAME <br /> 120VAC S NAC-2 EXISTING NOTIFICATION: REMAINING THE SAME <br /> (DEDICATED CKT.) <br /> ❑ B ERY <br /> Drawings reviewed by: DRAWN CRL <br /> Brady B.Haws SET UNICAD JOB#23538 <br /> NICET Certification CHECKED BRADY B.HAWS <br /> FIRE ALARM RISER DIAGRAM Fire Protection Engineering Technology NICET IV138751 <br /> SCHEMATIC NOT TO SCALE Fire Alarm Systems-Level IV DATE 9/18/2023 <br /> Cert.No.138751 <br /> EXp 5/1/2025 REVISION 0 <br /> I SCALE <br /> �6y <br /> 6- -S.. <br /> UNICADInc <br /> °T34315 FA-1 <br /> Office:BD1.985.D410 � <br /> .unkotl.nll <br />