M <br /> N <br /> GENERAL NOTES: <br /> _ _ o <br /> FIRE ALARM SYMBOL LEGEND > - '' Nca F 1. SCOPE OF WORK: THIS PROJECT SHALL INCLUDE THE INSTALLATION OF AN DMP \ <br /> NOTE. a SYMBas-NOT BE USED M THIS BBaEDT _ ,, o - •L DUALCOM COMMUNICATOR TO AN EXISTING EDWARDS LSS4-12 PANEL. <br /> SYMBOL DESCRIPTION MANUF. & PART # MOUNTING MOUNT IN OTY p ,.yam`A. 2. THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO THE ARCHITECTURAL DRAWINGS <br /> FOR EXACT DIMENSIONS. <br /> FACP FIRE ALARM CONTROL PANEL EST-LSS4-12 EXISTING EXISTING - �` o <br /> COM FIRE ALARM COMMUNICATOR DMP- DUALCOMNF-LV(A) WALL-TOP•66" ICABINET INCLUDED t � � _ - N- �" •� 3. INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND ALL OTHER APPLICABLE o <br /> 0 CODES AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. x <br /> ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION O r 55�© _ °O�° v 25 <br /> E EXISTING AWG AMERICAN WIRE GAUGE LIS001 OR MO7 4. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY W a <br /> G WITH GUARD TWP TWISTED PAIR (I -DENOTES LOOP A - E O B DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING c <br /> P PENDENT MOUNT TWSP TWISTED SHIELDED PAIR (s a u-I>ENDEEs SENSOR oHuolwlE f) ., - _ CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA o <br /> R RESIDENTIAL 110V FPLP FIRE POWER LIMITED PLENUM 1- 1s 2 TWP _ - >�,+ SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS W <br /> S SOUNDER BASE FPLR FIRE POWER LIMITED RISER wRE TYPE ABBRLvuEED • (*� LONG AS NO 11 OV OR HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. N <br /> WP WEATHERPROOF CONWCTOR COUNT <br /> .L <br /> EOL END OF LINE RESISTOR r �p MES(IF OMRIED �� $ I � ~� 5. FIRE RATINGS SHALL BE MAINTAINED FOR ALL PENETRATIONS THROUGH FIRE-RATED z <br /> EOLR END OF LINE RELAY 15 30 �NLY 1 CABIE NEEDED) >' ^"L�- d - CONSTRUCTION. <br /> r?} a > o <br /> 6. POWER FOR ALL FIRE ALARM PANELS AND FIRE ALARM POWER SUPPLIES MUST BE rc <br /> PROVIDED BY A DEDICATED AC BRANCH CIRCUIT. THE LOCATION OF THE BRANCH <br /> f t ' - , CIRCUIT BREAKER SHALL BE PERMANENTLY IDENTIFIED AT THE CONTROL UNIT, <br /> F MECHANICALLY PROTECTED, ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL AND Zco <br /> a a g 1p SHALL BE RED AND LABELED "FIRE ALARM CIRCUIT CONTROL" IN ACCORDANCE � <br /> WITH NFPA 72. ELECTRICAL CONTRACTOR SHALL PERFORM LOAD CALCULATIONS TO O �? <br /> x DETERMINE SIZE OF WIRING AND BREAKERS FOR ALL FIRE ALARM AC BRANCH co <br /> CIRCUITS BASED ON THE INFORMATION PROVIDED IN THE BATTERY CALCULATIONS CQ <br /> a s o g o z \ _> s FOR THE FIRE ALARM EQUIPMENT. o <br /> OPERATIONS 4 y �=1 `'' �� <br /> MATRIX z �- r 7. POWER-LIMITED AND NONPOWER-LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED V <br /> o a i o N z a - r W IN CABINET. ALL POWER-LIMITED CIRCUIT WIRING MUST REMAIN AT LEAST 0.25" <br /> EXISTING SYSTEM OPERATIONS;SHALL y x r A "I AWAY FROM ANY NONPOWER-LIMITED CIRCUIT WIRING. FURTHERMORE, ALL <br /> REMAIN,FIELD VERIFY ACTUAL SYSTEM o y z & 30S ay POWER-LIMITED AND NONPOWER-LIMITED CIRCUIT WIRING MUST ENTER AND EXIT <br /> OPERATIONS z v9 <br /> THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATE CONDUITS. <br /> Edm k+ a z w LL E <br /> c a N a a 3 N i i W 8. WHEN UTILIZING CLASS "A" CIRCUITS, SEPARATE OUTGOING AND RETURN d <br /> a r w w w w w w w o N CONDUCTORS OF CLASS "A" CIRCUITS BY A MINIMUM OF 12" WHERE RUN Q w <br /> VERTICALLY AND 48" WHERE RUN HORIZONTALLY. (n zn <br /> FIRE ALARM INPUT Y c a a a a a a a vi s z VICINITY MAP Q J <br /> N 9. WHEN UTILIZING SHIELDED CABLE TIE SHIELDS THROUGH AND INSULATE AT EACH <br /> SMOKE DETECTORS • • • • • • • • • SCHEMATIC:NOT TO SCALE JUNCTION BOX. INSULATE AND TAPE BACK AT END. Q <br /> HEAT DETECTORS • • • • • • • • E- <br /> 10. ALL FIRE ALARM CABLING SHALL BE ACCEPTABLE TO THE FIRE ALARM EQUIPMENT <br /> KITCHEN HOOD • • • • • • • • MANUFACTURER FOR THE INTENDED PURPOSE. CABLES USED IN VERTICAL RUNS <br /> SHALL BE TYPE FPLP OR FPLR. CABLE SPLICES OR TERMINATIONS SHALL BE MADE <br /> PULL STATIONS • • • • • • • • IN LISTED FITTINGS, BOXES, ENCLOSURES, FIRE ALARM DEVICES, OR UTILIZATION In, <br /> WATERFLOW SWITCHES • • • • • • • • EQUIPMENT. WHERE INSTALLED EXPOSED, CABLES SHALL BE ADEQUATELY <br /> VALVE SUPERVISORY SWITCHES • • • • SUPPORTED AND INSTALLED IN SUCH A WAY THAT MAXIMUM PROTECTION AGAINST c <br /> PHYSICAL DAMAGE IS AFFORDED BY BUILDING CONSTRUCTION. WHERE LOCATED <br /> DUCT DETECTORS • • • • • • WITHIN 7 FT OF THE FLOOR, CABLES SHALL BE SECURELY FASTENED IN AN <br /> FIRE ALARM AC POWER FAIL • • • • APPROVED MANNER AT INTERVALS OF NOT MORE THAN 18 IN. <br /> FIRE ALARM LOW BATTERY • • • • 11. SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION <br /> OPEN CIRCUIT • • • • CLEAN-UP IS COMPLETED AND FINAL. <br /> GROUND FAULT • • • • RETTURNUPPLY DIFFUSER <br /> PENDANT MOUNTED NOTE:MEASUREMENTS 12. LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEEL FROM MECHANICAL <br /> NAC SHORT CIRCUIT • • • • CEILING-MOUNTED J( AUDIBLE/VISUAL SHOWN ARE TO THE DIFFUSERS. WALL-MOUNTED SMOKE DETECTORS SHALL BE LOCATED A MAXIMUM OF <br /> 4"MIN HEAT DETECTOR VCEILING APPLIANCES CLOSEST POINT OF 12" FROM CEILING. <br /> LOSS OF AC TO BUILDING • DETECTOR <br /> 4"MIN 6"MIN. 36"MIN 13. PROVIDE SYNCHRONIZATION OF ALL VISUAL NOTIFICATION APPLIANCE CIRCUITS. <br /> 14"MAX AUDIBLE/VISUAL 12"MAX PROVIDE ALL REQUIRED SYNC MODULES. PROVIDE A MULTI-SYNC MODE SLAVE <br /> EVER AND/OR VISUAL AUDIBLE-ONLY REMOTE ALARM CEILING MOUNTED CEILING MOUNTED <br /> / ® APPLIANCES INDICATOR SMOKE/HEAT AUDIBLE/VISUAL CONNECTION BETWEEN ALL SYNC MODULES. <br /> HERE ONLY APPLIANCE 0 o DETECTOR APPLIANCES WALL-MOUNTED <br /> SMOKE DETECTOR 14. VERIFY ALL FIELD SELECTABLE AUDIBILITY SETTINGS OF NOTIFICATION APPLIANCES <br /> WALL-MOUNTED WITH FIRE ALARM CONTRACTOR. W <br /> HEAT DETECTOR DOOR WIDTH VI <br /> LESS 3L-4 15. UPON COMPLETION OF THE FIRE ALARM SYSTEM INSTALLATION AND PROGRAMMING, <br /> 6" THE INSTALLING CONTRACTOR SHALL PERFORM FINAL TESTING OF THE ENTIRE Q <br /> FSA D ORMAGNETIC� 30' MAX SYSTEM, PER ALL APPLICABLE CODES, AND SHALL COORDINATE AND PERFORM A O ; <br /> SIDE WALL FINAL FIRE ALARM SYSTEM INSPECTION. <br /> FACP <br /> � DOCUMENTS <br /> 80"-96" 90"MIN. 10' MAX HOLDER 30'MAX 16. PROVIDE OFF-SITE MONITORING AS REQUIRED BY THE INTERNATIONAL FIRE CODE, Q Q <br /> TO LOWEST WHERE CEILING AFF AFT N <br /> G PART OF LENS HEIGHT ALLOWS 5,MAX.---I SECTION 907.6.6 AND THE LOCAL AUTHORITY HAVING JURISDICTION. (/) J 0 J <br /> ss"To ss"To 66"To FROM EXIT FINISHED 17. INSTALLING CONTRACTOR SHALL, PHYSICALLY, LABEL ALL INITIATING DEVICES AND Lu J <br /> FACP TOP OF TOP OF TOP OF T. <br /> WALL NOTIFICATION APPLIANCE CIRCUIT END OF LINE (WHEN WIRING CLASS "B"). THESE II.- Q Q <br /> LSS4-12 FSA FACP CABINET MANUAL LABELS SHALL BE IN PLACE PRIOR TO START-UP AND TESTING. � 0 <br /> V PULL 42 148 <br /> • <br /> FINISHED STAPON 18. ROOMS CONTAINING CONTROLS FOR AIR-CONDITIONING SYSTEMS, SPRINKLER RISERS Q <br /> ZONE-1 EXISTING INITIATING:REMAINING THE SAME FLOOR AND VALVES OR OTHER FIRE DETECTION, SUPPRESSION OR CONTROL ELEMENTS 0 Q <br /> SHALL BE IDENTIFIED WITH PERMANENTLY MOUNTED SIGNS WITH LETTERING NOT Q J <br /> LESS THAN 2 INCHES TALL WITH A PRINCIPAL STROKE OF NOT LESS THAN 3/8 <br /> ALARM INCH. LETTERS SHALL CONTRAST WITH BACKGROUND. C U LV Q <br /> TROUBLE FIRE ALARM DEVICE MOUNTING HEIGHTS O W W C O <br /> SCALE:NOT TO SCALE <br /> NAC-1 EXISTING NOTIFICATION: REMAINING THE SAME N <br /> I.L W <br /> DMP N M <br /> CELLULAR NAC-2 EXISTING NOTIFICATION: REMAINING THE SAME Q <br /> FIREALARM <br /> COMMUNICATOR <br /> NAC-3 EXISTING NOTIFICATION: REMAINING THE SAME <br /> 120VAC <br /> (DEDICATED CKT.) <br /> NAC-4 EXISTING NOTIFICATION: REMAINING THE SAME <br /> ❑ B ERY <br /> Drawings reviewed by: DRAWN CRL <br /> Brady B.Haws SET UNICAD JOB#23693 <br /> NICET Certification CHECKED BRADY B.HAWS <br /> FIRE ALARM RISER DIAGRAM Fire Protection Engineering Technology NICET IV138751 <br /> SCHEMATIC NOT TO SCALE Fire Alarm Systems-Level N DATE 11/27/2023 <br /> Cert.No.138751 <br /> EXp 5/1/2025 REVISION 0 <br /> SCALE 1/8•=1'-0" <br /> HOo IWO& <br /> aw aeon s". <br /> °T�315 FA-1 <br /> .unlWE.nl1 <br />