My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1509 CALIFORNIA ST DAWSON PLACE 2024-10-16
>
Address Records
>
CALIFORNIA ST
>
1509
>
DAWSON PLACE
>
1509 CALIFORNIA ST DAWSON PLACE 2024-10-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/16/2024 7:31:47 AM
Creation date
9/30/2024 10:25:56 AM
Metadata
Fields
Template:
Address Document
Street Name
CALIFORNIA ST
Street Number
1509
Tenant Name
DAWSON PLACE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
dynamically reassigned to the next highest Typical Wiring <br /> priority failed amplifier actively processing <br /> messages To next remote <br /> floor panel <br /> The Firefighters Telephone Control unit <br /> (FTCU)provides two-way communications <br /> between remotely located phones and the <br /> 2 Tw.Pr. 3 Pr. 3 Pr. <br /> fire command center.The alphanumeric 1 Tw/Sh Pr 21 2 2 2 2 F <br /> display makes operation intuitive, and a <br /> single switch permits the phone signals to Pr. CR MM FIRE F WEVEL <br /> 2 <br /> be used to issue pages in the facility. HVAC HVAC'� DAMPER MM MONITOR <br /> CONTROL MONITOR 2 2 � 2 2 F <br /> Digitized audio increases notification mes- ccsq Pr <br /> saging flexibility, reduces wiring and instal- 4th FLOOR • • • • • • • • • • • • • • • • • • • <br /> lation costs, provides enhanced supervi- 1 Pr& 3 Pr, <br /> 3 Pr. <br /> sion and survivability, and is easy to use. 2 Tw/Sh Pr. <br /> 2 MM j 2 2 2 2 21:7 <br /> Enhanced Reliability&Survivability Remote 1 Pr. , <br /> Floor Panel 2 2 2 F(Node) CRITICAL PROCESSThe EST3 uses distributed technology, MONITOR <br /> 1 Pr&designed to survive expected and un- POWe" 2 Tw/Sh Pr. 1 Tw/Sh Pr. 2 2 <br /> expected events including earthquakes. Source CC <br /> F <br /> Simple-to-install kits provide internal hard- <br /> ening that meets ;requirements defined by /7/ T, <br /> 3 Pr <br /> Uniform Building Code(UBC 1997);Inter- CPuower , <br /> national Building Code(IBC 2006); and, p&booster, <br /> dual loop <br /> Acceptance Criteria for Seismic Qualifica- module 1 Tw/Sh Pr. <br /> tion by Shake-Table Testing of Nonstruc- &batteries CC �I <br /> tural Components and Systems(AC-156). 1 Pr&2 Tw/Sh Pr. <br /> Seismic component importance factor 27ma Pc 10-- <br /> .ud <br /> MM HVAC MONITOR SPRINKLER <br /> of 1.5 can be met b adding appropriate 1 Tw/Sh Pr. WATERFLOW SUPERVISORY <br /> y g .There CR —�HVACCONTROL F SWITCH SWITCH <br /> anchorage for local conditions.There is no rk _ _ <br /> need for special installation methods for oo toll, 2 CR F CT CT <br /> EST3 field devices including signals and &telephone <br /> detection devises. By following standard ELEVATOR CAPTURE <br /> mounting methods, along with any local 2nd FLOOR • • • • • • . . . . . . . . . . . . . • • • • • • • • • • . . . . . . . . . . . . . . . . <br /> requirements, seismic Importance Fac- <br /> tor 1.5 may be gained in order to further <br /> enhance system survivability. 3 Pr. <br /> On the initiating side, intelligent Signature 2 2 2 2 2 2 F <br /> 1 Pr. CR MM WATER <br /> Series detectors Carl make alarm deci- DAMPER F MM MLEVEL <br /> ONITOR <br /> sions on their own, and do not involve HVAC HVAC <br /> CONTROL MONITOR <br /> other system components in this important COCC 2 F <br /> decision-making process. Sensor-based 1st FLOOR t T <br /> technology must communicate data to a 3 Pn Pr. . . . . . . . . . . . . . . . . . . . . . . • • • • • • • • . . . . . . . . . . . . . <br /> s Pr. <br /> remotely located common panel where 2 Pr& Pr. <br /> alarm decisions are made. Failure of this <br /> centralized processor can cripple Sensor- <br /> based systems.With EST3, a panel CPU <br /> failure does not disable a panel's ability to 1 Pr. 2 2 2 2 2 2 F 2 <br /> provide protection. In the event of a CPU <br /> failure,the intelligent device controllers can 1 Pr& 2 2 2 2 2 2 F <br /> still receive alarms and distribute the alarm 2 Tw/Sh Pr. <br /> information to all other modules in the CC F <br /> panel. Modules in the panel are capable of 1 Tw/Sh Pr. <br /> responding with a programmed standalone Primary Central <br /> alarm response. Power ce © TELCO Monitoring <br /> Station <br /> When a network is wired in a Class B LA' CPU w/Pispl power supply&booster, <br /> dual module,audio source module w/master <br /> firefighthter's telephone,2 amplifiers,&batteries <br /> configuration, a single break or short on Printer <br /> the wiring isolates the system into two GROUND FLOOR <br /> groups of panels. Each group continues <br /> to function as a peer-to-peer network, <br /> working with their combined databases. <br /> When wired using a Class A configuration, <br /> Page 3 of 4 DATA SHEET E85010-0145 <br /> Not to be used for installation purposes. Issue 1.3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.