Laserfiche WebLink
dynamically reassigned to the next highest Typical Wiring <br /> priority failed amplifier actively processing <br /> messages To next remote <br /> floor panel <br /> The Firefighters Telephone Control unit <br /> (FTCU)provides two-way communications <br /> between remotely located phones and the <br /> 2 Tw.Pr. 3 Pr. 3 Pr. <br /> fire command center.The alphanumeric 1 Tw/Sh Pr 21 2 2 2 2 F <br /> display makes operation intuitive, and a <br /> single switch permits the phone signals to Pr. CR MM FIRE F WEVEL <br /> 2 <br /> be used to issue pages in the facility. HVAC HVAC'� DAMPER MM MONITOR <br /> CONTROL MONITOR 2 2 � 2 2 F <br /> Digitized audio increases notification mes- ccsq Pr <br /> saging flexibility, reduces wiring and instal- 4th FLOOR • • • • • • • • • • • • • • • • • • • <br /> lation costs, provides enhanced supervi- 1 Pr& 3 Pr, <br /> 3 Pr. <br /> sion and survivability, and is easy to use. 2 Tw/Sh Pr. <br /> 2 MM j 2 2 2 2 21:7 <br /> Enhanced Reliability&Survivability Remote 1 Pr. , <br /> Floor Panel 2 2 2 F(Node) CRITICAL PROCESSThe EST3 uses distributed technology, MONITOR <br /> 1 Pr&designed to survive expected and un- POWe" 2 Tw/Sh Pr. 1 Tw/Sh Pr. 2 2 <br /> expected events including earthquakes. Source CC <br /> F <br /> Simple-to-install kits provide internal hard- <br /> ening that meets ;requirements defined by /7/ T, <br /> 3 Pr <br /> Uniform Building Code(UBC 1997);Inter- CPuower , <br /> national Building Code(IBC 2006); and, p&booster, <br /> dual loop <br /> Acceptance Criteria for Seismic Qualifica- module 1 Tw/Sh Pr. <br /> tion by Shake-Table Testing of Nonstruc- &batteries CC �I <br /> tural Components and Systems(AC-156). 1 Pr&2 Tw/Sh Pr. <br /> Seismic component importance factor 27ma Pc 10-- <br /> .ud <br /> MM HVAC MONITOR SPRINKLER <br /> of 1.5 can be met b adding appropriate 1 Tw/Sh Pr. WATERFLOW SUPERVISORY <br /> y g .There CR —�HVACCONTROL F SWITCH SWITCH <br /> anchorage for local conditions.There is no rk _ _ <br /> need for special installation methods for oo toll, 2 CR F CT CT <br /> EST3 field devices including signals and &telephone <br /> detection devises. By following standard ELEVATOR CAPTURE <br /> mounting methods, along with any local 2nd FLOOR • • • • • • . . . . . . . . . . . . . • • • • • • • • • • . . . . . . . . . . . . . . . . <br /> requirements, seismic Importance Fac- <br /> tor 1.5 may be gained in order to further <br /> enhance system survivability. 3 Pr. <br /> On the initiating side, intelligent Signature 2 2 2 2 2 2 F <br /> 1 Pr. CR MM WATER <br /> Series detectors Carl make alarm deci- DAMPER F MM MLEVEL <br /> ONITOR <br /> sions on their own, and do not involve HVAC HVAC <br /> CONTROL MONITOR <br /> other system components in this important COCC 2 F <br /> decision-making process. Sensor-based 1st FLOOR t T <br /> technology must communicate data to a 3 Pn Pr. . . . . . . . . . . . . . . . . . . . . . . • • • • • • • • . . . . . . . . . . . . . <br /> s Pr. <br /> remotely located common panel where 2 Pr& Pr. <br /> alarm decisions are made. Failure of this <br /> centralized processor can cripple Sensor- <br /> based systems.With EST3, a panel CPU <br /> failure does not disable a panel's ability to 1 Pr. 2 2 2 2 2 2 F 2 <br /> provide protection. In the event of a CPU <br /> failure,the intelligent device controllers can 1 Pr& 2 2 2 2 2 2 F <br /> still receive alarms and distribute the alarm 2 Tw/Sh Pr. <br /> information to all other modules in the CC F <br /> panel. Modules in the panel are capable of 1 Tw/Sh Pr. <br /> responding with a programmed standalone Primary Central <br /> alarm response. Power ce © TELCO Monitoring <br /> Station <br /> When a network is wired in a Class B LA' CPU w/Pispl power supply&booster, <br /> dual module,audio source module w/master <br /> firefighthter's telephone,2 amplifiers,&batteries <br /> configuration, a single break or short on Printer <br /> the wiring isolates the system into two GROUND FLOOR <br /> groups of panels. Each group continues <br /> to function as a peer-to-peer network, <br /> working with their combined databases. <br /> When wired using a Class A configuration, <br /> Page 3 of 4 DATA SHEET E85010-0145 <br /> Not to be used for installation purposes. Issue 1.3 <br />