My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6200 12TH DR SE 2024-10-14
>
Address Records
>
12TH DR SE
>
6200
>
6200 12TH DR SE 2024-10-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/14/2024 2:13:44 PM
Creation date
9/30/2024 11:16:47 AM
Metadata
Fields
Template:
Address Document
Street Name
12TH DR SE
Street Number
6200
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
162
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BRANOM <br /> Measure.Test.Automate. <br /> Branom Instrument Company <br /> 5610 4th Ave S. <br /> Seattle WA 98108 <br /> United States <br /> Certificate of Calibration#:BIC 12680 <br /> Customer Name: Neudorfer Engineers Inc <br /> Address: 5516 1st Ave SSeattle Washington(US)98108 <br /> P 0#: SEA-01 <br /> Instrument Description: Fluke 323 <br /> Serial Number: 47643927MV Calibration Date: 12/28/2023 <br /> Customer ID: N/A Calibration Due: 12/281'2024 <br /> Condition Found: In Tolerance Branom Order#: SO-61148 <br /> Condition Left: In Tolerance <br /> Test Procedure Used: BIC-0061 <br /> Temperature(°F): 73.7 <br /> Humidity 1%): 35.3 Issued By: Walter Higdon II <br /> Branom Standards Used: <br /> Asset Asset Serial Number Cal Due Date <br /> Fluke 5560A(Demo) 6011604 01/22/2024 <br /> Instrument Accuracy: <br /> See Manufacturer"s Specifications <br /> Calibration Results: <br /> Applied Value Measured Value Lower Limit Higher Limit Unit of Measure Measure/Source Pass/Fail <br /> 10 10.0 9.3 10.7 VAC,50 Hz Measure Pass <br /> 600 599.3 590.5 609.5 VAC,50 tlz Measure Pass <br /> 600 598.9 590.5 609.5 VAC,400Hz Measure Pass <br /> -600 -599.3 -606.5 -593.5 VDC Measure Pass <br /> 10 10.0 9.4 10.6 VDC Measure Pass <br /> 600 599.7 593.5 606.5 VDC Measure Pass <br /> 10 10.0 9.4 10.6 9 Measure Pass <br /> 350 349.7 346.0 354.0 4 Measure Pass <br /> 3500 3499 3460 3540 9 Measure Pass <br /> 0.12 6.0 5.4 6.6 AAC,50Hz Measure Pass <br /> 0.48 24.2 22.9 25.1 AAC,150Hz Measure Pass <br /> 4.2 209.5 205.3 214.7 AAC,50Hz Measure Pass <br /> 7.8 390.0 381.7 398.3 AAC,50Hz Measure Pass <br /> Notes: <br /> B-ni Inswment Company certifies that the following instrument meets or-eels all published spe if cations and has been calbratec using standards whose accuracies are hateable to the Natarull Institute of standards and Techmiagy.rNs cenlhcate appl-only <br /> to the instrument I-�Ued below.This cert'iriwte shall no:be reproduced-cot in full wltho"written approval of 8-m hutrument Company CMif cate Revised 05.0L12020 <br /> Phone:+1 206-762-6050 Email:sales@branom.com Website:https://www.branom.com <br /> Thank you for the opportunity to quote your equipment requirements. <br /> Page: 1 i 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.