My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6300 MERRILL CREEK PKY CREATION TECHNOLOGIES 2024-10-16
>
Address Records
>
MERRILL CREEK PKY
>
6300
>
CREATION TECHNOLOGIES
>
6300 MERRILL CREEK PKY CREATION TECHNOLOGIES 2024-10-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/16/2024 2:18:02 PM
Creation date
9/30/2024 1:16:40 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
6300
Tenant Name
CREATION TECHNOLOGIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Honeywell I Intelligent Fire Panel with Voice <br /> 3Ste' <br /> XMGHr <br /> 6820EVS <br /> Emergency Voice System and Fire Alarm <br /> Control Panel <br /> The 6820EVS is a fire alarm control panel(FACP)and emergency mass <br /> notification system conveniently integrated and housed in one panel,and <br /> meets the requirements for mass notification as described in UL 2572. <br /> The 6820EVS is a direct replacement for the 5820XL-EVS panel.The <br /> 6820EVS can be configured to achieve an overall point capacity of up to <br /> 1110 points and connect up to 17 panels in a single communications link. <br /> The 6820EVS has one built-in signaling line circuit(SLC),which can 6820EVS <br /> support 159(SK)System Sensor'sensors and 159 SK modules or 127 buildings where new wiring is not allowed,or to <br /> (SD)Hochiki°devices per loop.To increase point capability,additional SLC provide an easy install fire system for new <br /> Loops can be added using the 6815 SLC expander for SK devices or the construction projects.SWIFT devices can be <br /> 5815XL expander for SD devices,increasing the point capacityto a combined with other hard-wired 6820EVS <br /> maximum of 1110 points for SK devices and 635 points for SD devices. compatible devices. <br /> Three additional SLCs are needed to reach 1110 points(SK devices). Four <br /> The 6820EVS has aform-C trouble relay,and two <br /> additional SLCs are needed to reach 635 points(SD devices). <br /> programmable form-C relays,along with powerful <br /> The common communications and annunciation link allows up to 17 features such as drift compensation,pre-trouble <br /> panels to be connected via copper or fiber optic cable.A designated panel maintenance alert,a built-in sensor test to <br /> is configured as the communicator for all panels in the link for convenient complywith NFPA 72 calibration testing <br /> single-point communications.It also has a built-in,dual-line POTS and IP requirements,and calibration trouble alert.The <br /> communicator with optional cellular reporting available. 6820EVS supports a variety of devices,including <br /> the 6860,5860,and 6855 remote annunciators, <br /> The emergency communication system operations include an onboard 5824 serial parallel printer interface module(for <br /> supervised microphone,and all-call and non-active call buttons can printing system reports),the 5496 NAC expander, <br /> quickly select all active or all non-active output groups.The system also 5895XL power module,and SK or SD devices. <br /> allows for ECS messages to take priority over fire. <br /> The panel also has four user-programmable <br /> SWIFT° wireless compatibility provides options for wireless detection buttons which are ideal for programming simple, <br /> through a Class A mesh network.It is ideal for hard-to-wire locations, complex,and routine tasks. <br /> FEATURES & BENEFITS <br /> • Up to 1110 points for • 15 recordable one • Built-in annunciator • JumpStart°auto • Programmable date <br /> greater design minute messages can with a large 160 programming feature setting for automatic <br /> flexibility.Additional be mapped to eight character,4 x40 LCD for easy programming and Daylight Saving <br /> SLCs can be added different EVS buttons display . Built-in dual path Time changes <br /> until maximum point . Built-in USB interface • Four user- POTS and IP • Flexput°circuits can <br /> levels are reached for convenient programmable communications with be individually <br /> • Connect up to 17 programming buttons minimize time optional cellular programmed to <br /> panels on one site with . Convenient spent executing models available for function as <br /> convenient single- field-upgradeable complex or routine reliable backup notification circuits, <br /> point access; firmware tasks reporting auxiliary power <br /> compatible with mixed 16 built-in speaker outputs,or initiating <br /> FACP models group switches; circuits that support <br /> expandable to 32 both 2-and 4-wire <br /> smoke detectors <br />
The URL can be used to link to this page
Your browser does not support the video tag.