Laserfiche WebLink
Envelope Leakage Test <br /> Testing Company: Technician: <br /> Name: Name: <br /> Address: Credentials: <br /> Email: <br /> Building Information: Customer Information: <br /> Project ID: Benton Square Name: <br /> Address: 1823 100th St SW Address: 1823 100th St SW <br /> Everett, WA 98204 Everett, WA 98204 <br /> Geo-Tag Data: Latitude: 47.907689 <br /> Longitude: -122.259134 <br /> Timestamp: 2024-06-12 11:28:14 <br /> Measured Leakage: 2.97 ACH50 <br /> Leakage Target: 3.00 ACH50 <br /> Compliance with Leakage Target: Pass <br /> Test ID: Lot 23 <br /> Purpose of Test: Seattle Multi <br /> Measured CFM50: 588.9 (+/- 1.1%) Effective Leakage Area: 38.8 in <br /> Building Volume: 11,900.0 ft3 Enclosure Surface Area: 1,400.0 ft2 <br /> Coefficient (C): 61.3 (+/-4.4%) Exponent (n): 0.579 (+/- 0.013) <br /> Correlation Coefficient: 0.99993 <br /> Test Standard: RESNET 380 Multi-Point Test Mode: Depressurize <br /> Test Characteristics: Indoor Temp: 67 OF Outdoor Temp: 67 OF <br /> Altitude: 546.0 ft Time Average Period: 10 seconds <br /> Test Date and Time: 2024-06-12 12:17:43 <br /> 800 <br /> 700 <br /> 600 • Depressurize <br /> E 500 <br /> U <br /> an <br /> 400 <br /> cKS <br /> -C'U' 300 <br /> a> <br /> J <br /> 0) <br /> 200 <br /> .5 <br /> m <br /> 100 <br /> 4 5 6 7 8 910 20 30 40 50 60 70 <br /> Building Pressure (Pa) <br />