Laserfiche WebLink
NORTH <br /> 0 verizon� <br /> W,c.,wnats Below. <br /> Call before you dig <br /> PROJECT: <br /> LEGEND: <br /> 1801AVAO.3 ROW EVT 0637 <br /> BORE/MISSILE BORE M,TTI-E"T,TY <br /> OPEN TRENCH CITY OF EVERETT <br /> SIDEWALK <br /> E.O.P EDGE OF PAVEMENT EVES ETT,WL CREEK PKWY <br /> EVERTT,WA <br /> B.O.0 BACK OF CURB <br /> R.O.W. RIGHT OF WAY <br /> C.L.--- STREET CENTERLINE <br /> • POTHOLE LOCATION 0 — Z <br /> O o <br /> v i � <br /> V Lu U LU J <br /> 0' 10, 20' 40' > � Q <br /> 00 Lu U) = z <br /> d <br /> N Z O O �_ <br /> 7 O C) <br /> N F z <br /> Z o <br /> W U <br /> C N c J In <br /> LU <br /> INSTALL 215 LF OF G o Uj - ° <br /> 1 -2" HDPE CONDUIT N o <br /> (TRENCH) u o <br /> (RESTORE TRENCH TO a <br /> OALL APPLICABLE STANDARDS) <br /> 0 <br /> 0 <br /> TREES 3+00 O _ FORESITE <br /> 1 — — �— ForesM1eGroup,lnc group <br /> J I wAW'.9+nc net <br /> — — • R• 3800 E Cesar Chavez St. a 1334.887.6064 <br /> RO — _ ^ O'•V. Austin,TX 78]02 88]6024 <br /> o 4+00�� Q <br /> o _ <br /> N <br /> 00 <br /> OC w <br /> — Z <br /> B _w —W —w B.O.C.'Cn J <br /> � SS � � <br /> _ 75TH ST SW_ Ss _ _ <br /> U � � <br /> _ SS _ <br /> AB <br /> s C L ENGINEER: <br /> S' DRAWN BY: NIL <br /> C•L REVISIONS <br /> n^TF DESCRIPTION INITIAL <br /> — NOTE TO CONTRACTOR: <br /> _ ANY BOREPITS DUG NEXT TO DRIPLINE OF AN EXISTING TREE <br /> G0 —� S W 1 /_ !'� TO BE DUGGED USING HYDRO VACCUUM EXCAVATION. <br /> G lI W GAS <br /> S�T <br /> /��[+ �'0 �ty� CAUTION! <br /> �`- C� (� ANY DISTURBANCE TO INFRASTRUCTURE WITHIN 15 FEET OF <br /> J J ADA RAMP WILL REQUIRE ENTIRE RAMP TO BE REPAIRED IN <br /> ACCORDANCE WITH ALL REQUIRED ADA STANDARDS AND <br /> SPECIFICATIONS. <br /> \ B O ALL TELECOM UTILITY LOCATIONS ON PRINT ARE BASED ON <br /> G/ FIELD SURVEY AND OBSERVATIONS.LOCATIONS MAY NOT BE <br /> ACCURATE OR COMPLETE. EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT <br /> V ' THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE <br /> CONTRACTOR TO PLACE UTILITY WITH A MINIMUM OF 36 PROPERTY OF MCI COMMUNICATIONS SERVICES,INC..BOT <br /> BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT B <br /> R INCHES OF COVER WHEN UNOBSTRUCTED.CONTRACTOR TO REPRODUCED, COPIED, OR USED FOR ANY PURPOSE <br /> R O•/ 0 MAINTAIN 24INCHES OF SEPARATION FROM OTHER UTILITIES. WITHOUT SPECIFIC WRITTEN PERMISSION. <br /> vv1 DEPTH TO BE ADJUSTED ACCORDINGLY. <br /> UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON SCALE <br /> DOCUMENT RESEARCH AND FIELD EVALUATION. THE <br /> INFORMATION MAY NOT BE ACCURATE OR COMPLETE.IT IS HORIZONTAL: 1"=20' <br /> THE CONTRACTOR'S RESPONSABILITY TO PHYSICALLY <br /> LOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES VERTICAL: N/A <br /> WITHIN CONSTRUCTION PATH. <br /> ALL INSTALLATIONS MUST COMPLY WITH MINIMUM <br /> HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES. <br /> SHEET: C-02 <br />