Laserfiche WebLink
NORTH <br /> U INSTALL 24 LF OF ju verizonv' <br /> Ic c went s below. <br /> 1 - 2" HDPE CONDUIT fall before you dig. <br /> (TRENCH) PROJEc oNDMaE6 PROJECT: <br /> (RESTORE TRENCH TO LEGEND: 1801AVAO.3 ROW EVT 0637 <br /> R.p ALL APPLICABLE STANDARDS) BORE/MISSILE BORE ,ERM,rT,N—T,TY <br /> STA: 6+39 OPEN TRENCH CITY OF EVERETT <br /> SIDEWALK 21EP.LoC <br /> co 2ER <br /> ( ) E.O.P EDGE OF PAVEMENT EVES ETT,WA <br /> CREEK PKWY <br /> BOREPIT/ INSTALL1 <br /> 36" x 60"x 36"VAULT B.O.0 BACK OF CURB EVERTT,WA <br /> e.p c � � INSTALL 71 LF OF R.O.W. <br /> R.O.W. RIGHT OF WAY <br /> 1 -2 HDPE CONDUIT C.L.--- STREET CENTERLINE <br /> fv) , (MISSILE BORE) • POTHOLE LOCATION Ov , zo Z <br /> cc \ CO EX STORM — L V 0 w g <br /> A�7 MAINTAIN 24" MIN B O C o 10 20 ao o w _ <br /> CLEARANCE z a Z <br /> C�. �STysTs� POTHOLE AND RESTORE v o <br /> E N U 1-- z <br /> v TO STANDARDS _ U V) Z w o <br /> v EX WATER zco <br /> a LU <br /> MAINTAIN 24" MIN < w J <br /> Q of <br /> CLEARANCE N o Df <br /> POTHOLE AND RESTORE — C.L. w ': z <br /> TO STANDARDS U o <br /> a <br /> EX SEWER / <br /> 1' MAINTAIN 24" MIN INSTALL 4 LF OF <br /> CLEARANCE <br /> 7+00 POTHOLE AND RESTORE <br /> B.O.C. ( )1 -2" HDPE CONDUIT FORESITE <br /> \ BORE POU <br /> TO STANDARDS F...GPXXIrc. 'Ivry h, <br /> I 38U0 E Cesar Chavez St. a 1334.887.60 <br /> O� <br /> Austin,T f X]8]02 334.88].6024 <br /> INSTALL 131 LF OF , �Z <br /> J' 1 -2" HDPE CONDUIT <br /> DES SSA (BORE) vim_ TA <br /> � I / <br /> N ` 8+00 / c, <br /> A. <br /> EX GAS L �s <br /> ® MAINTAIN 24" MIN EX WATER <br /> / CLEARANCE MAINTAIN 24" MIN 'r <br /> POTHOLE AND RESTORE �U CLEARANCE <br /> TO STANDARDS ��\ POTHOLE AND RESTORE <br /> TO STANDARDS ENGINEER: AB <br /> STA: 7+10 EX UG ELEC DRAWN BY: NL <br /> V� <br /> DIG (1) 5'x 5' BOREPIT MAINTAIN 24" MIN REVISIONS <br /> / CLEARANCE NOTE TO CON TRACTOR: nnTG DESCRIPTION INITIAL <br /> CONTRACTOR TO REPAIR ANY BOREPITS DUG NEXT TO DRIPLINE OF AN EXISTING TREE <br /> POTHOLE AND RESTORE TO BE DUGGED USING HYDRO VACCUUM EXCAVATION. <br /> ALL AFFECTED SIDEWALK TO STANDARDS <br /> PANELS IN ACCORDANCE WITH \ ANY <br /> TDO T'URBANCE TO INFRASTRUCTURE WITHIN 15 FEET OF <br /> ALL APPLICABLE STANDARDS STA: 8+41 ADA RAMP WILL REQUIRE ENTIRE RAMP TO BE REPAIRED IN <br /> ACCORDANCE WITH ALL REQUIRED ADA STANDARDS AND <br /> BOREPIT/ INSTALL (1) SPECIFICATIONS. <br /> 36"x 60"x 36"VAULT ALL TELECOM UTILITY LOCATIONS ON PRINT ARE BASED ON <br /> FIELD SURVEY AND OBSERVATIONS.LOCATIONS MAY NOT BE <br /> ACCURATE OR COMPLETE. EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT <br /> n THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE <br /> V" CONTRACTOR TO PLACE UTILITY WITH A MINIMUM OF 36 PROPERTY OF MCI COMMUNICATIONS SERwceS,INC..BOT <br /> \ BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT B <br /> INCHES OF COVER WHEN UNOBSTRUCTED.CONTRACTOR TO REPRODUCED, COPIED, CO USED N FOR ANY LPURPOSE <br /> B <br /> MAINTAIN 24 INCHES OF SEPARATION FROM OTHER UTILITIES. WITHOUT SPECIFIC WRITTEN PERMISSION. <br /> DEPTH TO BE ADJUSTED ACCORDINGLY. <br /> \ UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON SCALE <br /> DOCUMENT RESEARCH AND FIELD EVALUATION. THE <br /> INFORMATION MAY NOT BE ACCURATE OR COMPLETE.IT IS HORIZONTAL: 1"=20' <br /> \ THE CONTRACTOR'S RESPONSABILITY TO PHYSICALLY <br /> U LOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES VERTICAL: N/A <br /> n WITHIN CONSTRUCTION PATH. <br /> v ALL INSTALLATIONS MUST COMPLY WITH MINIMUM <br /> HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES. <br /> SHEET: C-04 <br />