Laserfiche WebLink
NORTH <br /> verizon- <br /> Knowwhans below. <br /> Call before you dig. <br /> PROJECT: <br /> 2831 COLBY AVE LEGEND: °TI�"MaFR <br /> 1703MNTR.006 ROW EVT 0578 <br /> BORE/MISSILE BORE IL -LNTI1 <br /> — — — OPEN TRENCH CITYOF EVERETT <br /> SIDEWALK <br /> EL <br /> E.O.P EDGE OF PAVEMENT 1602 HEWITT AVE <br /> INSTALL 95 LF OF CONTRACTOR TO REPAIR 1611 HEWITT AVE EVERETT,WA <br /> 1 -2" HDPE CONDUIT ALL AFFECTED SIDEWALK co B.O.0 BACK OF CURB <br /> R.O.W.(BORE) PANELS IN ACCORDANCE WITH RIGHT OF WAY = <br /> C.L. -- STREET CENTERLINE <br /> ALL APPLICABLE STANDARDS • LU <br /> POTHOLE LOCATION 0 z <br /> u O = o <br /> M w H a <br /> 11+00 R.O.W. -R.O.W. o 10 zo ao O Lu W <br /> TREES <br /> 0 1KE UGE UGE UGE � GE UGE UGE u v♦ Z o 0 <br /> - UGE <br /> a+ G r r W L J J <br /> o — —B.O.C. z a 11' <br /> / W — —W b STA: 11+85 W W w 0 <br /> Q V) v) Q w <br /> B.O.C. <br /> � 12+00 DIG (1) 5'x 5' BOREPIT w ■■■ z <br /> 0 <br /> u O Q <br /> z — GAS — EX GAS EX UG ELEC a o <br /> MAINTAIN 24" MIN MAINTAIN 24" MIN <br /> = CLEARANCE CLEARANCE <br /> v POTHOLE AND RESTORE POTHOLE AND RESTORE FORESITE <br /> TO STANDARDS TO STANDARDS group <br /> Foreslle Gmup,Inc. w 1 wrw.fgNc.net <br /> 3000 E Cesar Chavez St. 0 1 334.88T.8064 <br /> HEWITT AV — — _ O — C,L, 3Ite4BB f1334.8W.8024 <br /> C.L.— ° O Austin,TX]BT02 <br /> SS SS - - - SS <br /> B.O.C. - <br /> EX SEWER <br /> MAINTAIN 24" MIN EX WATER <br /> CLEARANCE MAINTAIN 24" MIN <br /> POTHOLE AND RESTORE CLEARANCE <br /> TO STANDARDS POTHOLE AND RESTORE <br /> TO STANDARDS <br /> B.O.C. <br /> • <br /> B.O.C.- <br /> INSTALL 88 LF OF STA: 12+73 ENGINEER: AB <br /> 1 - 2" HDPE CONDUITt12+82 <br /> BOREPIT/ INSTALL 1 DRAWN BY: PS <br /> (BORE) ( ) REVISIONS <br /> 30"x 48"x 24"VAULT DA DESCRIPTION INITIAL <br /> NOTE TO CONTRACTOR: <br /> R.O.W.— ANY BOREPITS DUG NEXT TO DRIPLINE OF AN EXISTING TREE <br /> R,O.W, TO BE DUGGED USING HYDRO VACCUUM EXCAVATION. <br /> CONTRACTOR TO REPAIR CAUTION!! <br /> ANY DISTURBANCE TO INFRASTRUCTURE WITHIN 15 FEET OF <br /> ALL AFFECTED SIDEWALK ADA RAMP WILL REQUIRE ENTIRE RAMP TO BE REPAIRED IN <br /> PANELS IN ACCORDANCE WITHW LLJ SPECIFICATIONS.ACCORDANCE <br /> ALL REQUIRED ADA STANDARDS AND <br /> ALL APPLICABLE STANDARDS Q <br /> ALL TELECOM UTILITY LOCATIONS ON PRINT ARE BASED ON <br /> FIELD SURVEY AND OBSERVATIONS.LOCATIONS MAY NOT BE <br /> INSTALL 9 LF OF ACCURATE OR COMPLETE. <br /> EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT <br /> THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE <br /> CONTRACTOR TO PLACE UTILITY WITH A MINIMUM OF 36 PROPERTY of MCI COMMUNICATIONS SERVICES,ING BOT <br /> 1 — 2" HDPE CONDUIT BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT B <br /> INCHES OF COVER WHEN UNOBSTRUCTED.CONTRACTOR TO ceD coPIED, OR USED FOR ANY PURPOSE <br /> MAINTAIN 24 INCHES OF SEPARATION FROM OTHER UTILITIES. our SPECIFIC WRITTEN PERKESION. <br /> (TRENCH) _ = DEPTH TO BE ADJUSTED ACCORDINGLY. <br /> It oo <br /> (RESTORE TRENCH TO O UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON SCALE <br /> DOCUMENT RESEARCH AND FIELD EVALUATION. THE <br /> ALL APPLICABLE STANDARDS) INFORMATION MAY NOT BE ACCURATE OR COMPLETE.IT IS HORIZONTAL: 1"=20' <br /> THE CONTRACTOR'S RESPONSABILITY TO PHYSICALLY <br /> LOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES VERTICAL: N/A <br /> 1602 HEWITT AVE I AALLHI INSOTALLATIONISN MUST COMPLY WITH MINIMUM <br /> HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES. <br /> SHEET: C-06 <br />