Laserfiche WebLink
NORTH <br /> ju /111� verizon' <br /> O C,/ Kn whays below. <br /> Call before you dig. <br /> PROJECT: <br /> -B.O.C. C/) LEGEND: PROJECi"" EB <br /> � 1801AUJE.19 ROW EVT 0580 <br /> BORE/MISSILE BORE 1EEMTTI <br /> C.L. — OPEN TRENCH CITY OF EVERETT <br /> SIDEWALK160LECTLICATI11 <br /> WALL ST E.O.P EDGE OF PAVEMENT EVE RTT,WA AVE <br /> C7 SS SS s EVERETT,WA <br /> �L� I - SS _ J JV B.O.0 BACK OF CURB <br /> R.O.W. RIGHT OF WAY <br /> C.L.--- STREET CENTERLINE o <br /> Sc, • POTHOLE LOCATION Ov z <br /> —B.O.C. '_. ' ' >v g <br /> w w I� 0' 10 20 40 _ <br /> VV N Z d z <br /> (7 <br /> \ Z � <br /> - SS ICl/ W/ E g N o > o <br /> 1+00 2+00 U g Q a o <br /> V1 J <br /> z a Q z) <br /> a LU = ° <br /> EX STORM Un a Lu <br /> R.O.W. MAINTAIN 24" MIN EX WATER w mom j o <br /> CLEARANCE INSTALL 184 LF OF MAINTAIN 24" MIN u o <br /> 1210 WALL ST 1 -2" HDPE CONDUIT CLEARANCE L0 a <br /> POTHOLE AND RESTORE POTHOLE AND RESTORE N <br /> P <br /> TO STANDARDS (BORE) TO STANDARDS <br /> DIG ( ) 5'x 5' BOREPIT FORE <br /> SITE <br /> GRAND AVE MAINTAIN 24" MIN gro E <br /> CONTRACTOR TO REPAIR <br /> ^ 300 CLEARANCE Z Peresn�co „I„M 9'`e' <br /> f0E Cesarhavez C Sf. a 1 334.887.6064 <br /> vJ Sure 400 f334.88].6024 <br /> AFFECTED PAVEMENT POTHOLE AND RESTORE -1 AL1,T%]6]02 <br /> IN ACCORDANCE WITH TO STANDARDS = <br /> ALL APPLICABLE STANDARDS I v <br /> INSTALL 64 LF OF Q <br /> 1 - 2" HDPE CONDUIT <br /> (BORE) Ss SS - — SS - <br /> EX SEWER — <br /> MAINTAIN 24" MIN <br /> pkp0 M CLEARANCE <br /> POTHOLE AND RESTORE <br /> TO STANDARDS 3002 GRAND AVE ENGINEER: AB <br /> STA: 0+05 DRAWN BY: Ps <br /> INSTALL (1) Z REVISIONS <br /> 48"x 48"x 48" MANHOLE p 11T1 DESCRIPTION INITIAL <br /> D NOTE TO CONTRACTOR: <br /> ANY BOREPITS DUG NEXT TO DRIPLINE OF AN EXISTING TREE <br /> INSTALL 5 LF OF m <br /> TO BE DUGGED USING HYDRO VACCUUM EXCAVATION. <br /> � <br /> 1 -2" HDPE CONDUIT CAUTION" <br /> ANY DISTURBANCE TO INFRASTRUCTURE WITHIN 15 FEET OF <br /> (TRENCH) ADA RAMP WILL REQUIRE ENTIRE RAMP TO BE REPAIRED IN <br /> ACCORDANCE WITH ALL REQUIRED ADA STANDARDS AND <br /> (RESTORE TRENCH TO SPECIFICATIONS. <br /> ALL APPLICABLE STANDARDS) FA <br /> L TELECOM UTILITY LOCATIONS ON PRINT ARE BASED ON <br /> LD SURVEY AND OBSERVATIONS.LOCATIONS MAY NOT BE <br /> — CURATE OR COMPLETE. EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT <br /> THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE <br /> CONTRACTOR TO PLACE UTILITY WITH A MINIMUM OF 36 PROPERTY OF MCI COMMUNICATIONS SERVICES,INC..BOT <br /> CB BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT B <br /> INCHES OF COVER WHEN UNOBSTRUCTED.CONTRACTOR TO REPRODUCED, COPIED, OR USED FOR ANY PURPOSE <br /> MAINTAIN 24 INCHES OF SEPARATION FROM OTHER UTILITIES. WITHOUT SPECIFIC WRITTEN PERMISSION. <br /> DEPTH TO BE ADJUSTED ACCORDINGLY. <br /> CkCLT- UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON SCALE <br /> _ DOCUMENT RESEARCH AND FIELD EVALUATION. THE <br /> m m ZJ W INFORMATION MAY NOT BE ACCURATE OR COMPLETE.IT IS HORIZONTAL: 1"=20' <br /> THE CONTRACTOR'S RESPONSABILITY TO PHYSICALLY <br /> O]Q b O O O LOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES VERTICAL: N/A <br /> CC C WITHIN CONSTRUCTION PATH. <br /> ��� •I I C I— ALL INSTALLATIONS MUST COMPLY WITH MINIMUM <br /> •I HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES. <br /> SHEET: C-01 <br />