Laserfiche WebLink
NORTH <br /> ' verizon-,-�' <br /> 1 Know whatY bEIQW. <br /> ILR'JI Call before You dig. <br /> PROJECTDNUMeER PROJECT: <br /> 4230 COLBY AVE 4220 COLBY AVE LEGEND. 1703MNTR.005 ROW EVT 1327 <br /> BORE/MISSILE BORE ,ERM,TTI-ENTI1 <br /> — OPEN TRENCH CITY OF EVERETT <br /> SIDEWALK <br /> R.O.W.— R.O.W. E.O.P EDGE OF PAVEMENT 4634ALGERAVE <br /> EVERETT,WA <br /> B.O.0 BACK OF CURB <br /> —!Y1 !1(1 —!1(1 t1(1 t1d t1d —11d 11d <br /> E.O.P R.O.W. RIGHT OF WAY <br /> S]D — sv9 s— o — wo wo E.O.P C.L.--- STREET CENTERLINE <br /> • POTHOLE LOCATION 0 z v z <br /> U — U (n Q <br /> 0' 10, 20' 40' > f 1W1 <br /> Ln z <br /> N Z I— O 0r <br /> NU c <br /> z <br /> z <br /> C Ln m J W o <br /> COLBY AVE _ — — _ C L a o z <br /> C.L. — — — L <br /> � W <br /> Lu �a� Z Q z <br /> U O v <br /> Q <br /> O O <br /> O <br /> + E.O.P + <br /> - � FORESITE <br /> Q E•o.P� < group <br /> 11 1 !� Foreslle GIInc. 1 waw.fglnc.net <br /> 11/ T T - �// 31 EC—Chavez St. u1334.88].8064 <br /> SUIte400 f1334.88].8024 <br /> ZAustin,%]B]02 <br /> w R.O.W. z <br /> v R.O.W. INSTALL 220 LF OF v <br /> Q 1 -2" HDPE CONDUIT Q <br /> (BORE) g <br /> ENGINEER: AB <br /> DRAWN BY: PS <br /> REVISIONS <br /> DA DESCRIPTION INITIAL <br /> NOTE TO CONTRACTOR: <br /> ANY BOREPITS DUG NEXT TO DRIPLINE OF AN EXISTING TREE <br /> TO BE DUGGED USING HYDRO VACCUUM EXCAVATION. <br /> CAUTION!! <br /> ANY DISTURBANCE TO INFRASTRUCTURE WITHIN 15 FEET OF <br /> ADA RAMP WILL REQUIRE ENTIRE RAMP TO BE REPAIRED IN <br /> ACCORDANCE WITH ALL REQUIRED ADA STANDARDS AND <br /> SPECIFICATIONS. <br /> ALL TELECOM UTILITY LOCATIONS ON PRINT ARE BASED ON <br /> FIELD SURVEY AND OBSERVATIONS.LOCATIONS MAY NOT BE <br /> ACCURATE OR COMPLETE. EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT <br /> THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE <br /> CONTRACTOR TO PLACE UTILITY WITH A MINIMUM OF 36 PROPERTY of MCI COMMUNICATIONS SERVICES,INC..Bo <br /> INCHES OF COVER WHEN UNOBSTRUCTED.CONTRACTOR TO aEVNRaoEucED G.PIEDT CONFIDENCE <br /> ORE.D Foe ANY PURPos <br /> n MAINTAIN 24 INCHES OF SEPARATION FROM OTHER UTILITIES. WITHOUT SPECIFIC WRITTEN PERMIs3ION. <br /> 1 DEPTH TO BE ADJUSTED ACCORDINGLY. <br /> UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON SCALE <br /> DOCUMENT RESEARCH AND FIELD EVALUATION. THE <br /> INFORMATION MAY NOT BE ACCURATE OR COMPLETE.IT IS HORIZONTAL: 1"=20' <br /> THE CONTRACTOR'S RESPONSABILITY TO PHYSICALLY <br /> LOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES VERTICAL: N/A <br /> WITHIN CONSTRUCTION PATH. <br /> ALL INSTALLATIONS MUST COMPLY WITH MINIMUM <br /> HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES. <br /> SHEET: C-06 <br />