Laserfiche WebLink
NORTH <br /> verizon <br /> 4012 COLBY AVE <br /> 4004 COLBY AVE Call eefore"I din. <br /> PROJECT: <br /> / <br /> R.O.W. —R.O.W. LEGEND: 1703IONMN T R 703TR.005 ROW EVT 1327 <br /> BORE/MISSILE BORE PERMITTINDENTI1 <br /> E.O.P E•O•P OPEN TRENCH CITY OFEVERETT <br /> SIDEWALK1—F--ATION <br /> � r ��g� 7�I) A�AFT Cf� CFI.) = E.O.P EDGE OF PAVEMENT 4634ALGERAVE <br /> cn SY1 � � EVERETT,WA <br /> B.O.0 BACK OF CURB <br /> R.O.W. RIGHT OF WAY <br /> C.L.--- STREET CENTERLINE <br /> • POTHOLE LOCATION 0 ' ` OZ = z <br /> LSS v I_- LU ° <br /> — SS SS SS u U Q <br /> 0' 10, 20' 40' > J <br /> — JS — SS SS [L z <br /> N Z I- OZ r <br /> L U z)L / Z o <br /> C.L. — — — COLBY AVE I CO J w o <br /> — -- — C.L. Z a <br /> � ¢ w O o <br /> 0 m <br /> I V) Z W <br /> U z <br /> O O <br /> CIDrn rn rn rn rn— —r rn rn nn— + <br /> N E.O.P � F.O N <br /> FORESITE <br /> Q SS 4 i I <br /> _ C p a ForesM1eGmup,lnc. group <br /> 3000 E Cesar Chavez St. <br /> I~ 22+00 23+00 24+00 F—400 f 1 334.88T.8024 <br /> y 2 R•O•\A/_ �// 334.88].8064 <br /> V Austin,TX—02 <br /> W LLJ <br /> Z \ L— Z <br /> J � J <br /> EX SEWER INSTALL 220 LF OF <br /> Q EX SEWER EX SEWER 1 -2" HDPE CONDUIT Q <br /> MAINTAIN 24" MIN MAINTAIN 24" MIN MAINTAIN 24" MIN CLEARANCE CLEARANCE CLEARANCE (BORE) <br /> POTHOLE AND RESTORE POTHOLE AND RESTORE POTHOLE AND RESTORE <br /> TO STANDARDS TO STANDARDS TO STANDARDS <br /> 4017 COLBY AVE A 4009 COLBY AVE DRAWN BY: PS <br /> 4005 COLBY AVE <br /> REVISIONS <br /> 4001 COLBY AVE DA DESCRIPTION INITIAL <br /> NOTE TO CONTRACTOR: <br /> ANY BOREPITS DUG NEXT TO DRIPLINE OF AN EXISTING TREE <br /> TO BE DUGGED USING HYDRO VACCUUM EXCAVATION. <br /> CAUTION!! <br /> ANY DISTURBANCE TO INFRASTRUCTURE WITHIN 15 FEET OF <br /> ADA RAMP WILL REQUIRE ENTIRE RAMP TO BE REPAIRED IN <br /> ACCORDANCE WITH ALL REQUIRED ADA STANDARDS AND <br /> SPECIFICATIONS. <br /> ALL TELECOM UTILITY LOCATIONS ON PRINT ARE BASED ON <br /> FIELD SURVEY AND OBSERVATIONS.LOCATIONS MAY NOT BE <br /> ACCURATE OR COMPLETE. EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT <br /> THESE DRAWINGS AND SIECIFICATIONS SHALL REMAIN THE <br /> CONTRACTOR TO PLACE UTILITY WITH A MINIMUM OF 36 RTY of MCI COMMUNICATIONS SERVICES,INC..BOTI- <br /> INCHES OF COVER WHEN UNOBSTRUCTED.CONTRACTOR TO aBE <br /> EvNRa__ DOPIEDT ORN USEDD Foe ANY PURPOSE <br /> MAINTAIN 24 INCHES OF SEPARATION FROM OTHER UTILITIES. TH-TSPECIFIC WRITTEN PERMISSION. <br /> DEPTH TO BE ADJUSTED ACCORDINGLY. <br /> UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON SCALE <br /> DOCUMENT RESEARCH AND FIELD EVALUATION. THE <br /> INFORMATION MAY NOT BE ACCURATE OR COMPLETE.IT IS HORIZONTAL: 1"=20' <br /> THE CONTRACTOR'S RESPONSABILITY TO PHYSICALLY <br /> LOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES VERTICAL: N/A <br /> WITHIN CONSTRUCTION PATH. <br /> ALL INSTALLATIONS MUST COMPLY WITH MINIMUM <br /> HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES. <br /> SHEET: C-11 <br />