Laserfiche WebLink
NORTH <br /> verizon <br /> ludo m t,below. <br /> Call before you dig. <br /> PROJECT: <br /> LEGEND: °TID"MaER <br /> MATCH LINE STA 28+50 BORE/MISSILE BORE 1703MNTR.005 ROW EVT 1327 <br /> OPEN TRENCH CITY OF EVERETT <br /> 3903 COLBY AVE I 0 U O SIDEWALK PRo—L.-TION <br /> Q <br /> � LlJ SS �w�� E.O.P 4634 ALGER AVE <br /> EDGE OF PAVEMENT EVERETT,WA <br /> Sri — B.O.0 BACK OF CURB <br /> sS I I I I R.O.W. RIGHT OF WAY <br /> INSTALL 25 LF OF EX GAS C.L.--- STREET CENTERLINE <br /> 1 -2" HDPE CONDUIT MAINTAIN 24" MIN I • POTHOLE LOCATION 0 Z __ <br /> J CLEARANCE w C, LU s <br /> (BORE) <br /> L 6' POTHOLE AND RESTORE u A Q a <br /> 0' 10, 20' 40, > W <br /> STA: 28+75 TO STANDARDS 0 L IZ z <br /> BOREPIT/ INSTALL (1) EX SEWER v z L 0 o <br /> R.O.W. 36"x 60"x 36"VAULT MAINTAIN 24" MIN R.O.W. E 7 � o <br /> CLEARANCE I U - J LU <br /> POTHOLE AND RESTORE _ w o <br /> rn rn o — TO STANDARDS rn E.O.P a o m <br /> E.O.P —/ MS Ln Q o <br /> EX WATER N u 0 <br /> MAINTAIN 24" MIN a <br /> CLEARANCE <br /> POTHOLE AND RESTORE <br /> TO STANDARDS 39TH ST 3 I 0 FORESIo E <br /> C.L.- INSTALL 72 LF OF - - -I- —C.L. o+ ForesM1e Gmup,Inc. .IaA.fglnc <br /> 1 - 2 HDPE CONDUIT 3000 E Ce ar Gave 8t. 11334.88➢.8064 <br /> " Aust 4W f 1334.88T.8024 <br /> Sulte <br /> INSTALL 133 LF OF T"T8T02 <br /> (BORE) 1 -2" HDPE CONDUIT <br /> E.O.P (BORE) E.O.P cn <br /> w <br /> —00 I " o z <br /> 30+00 `f J <br /> R.O.W. R.O.W. v <br /> 1 < <br /> STA: 29+47 EX SEWER I Q <br /> MAINTAIN 24" MIN N <br /> DIG (1) 3'x 3' BOREPIT — CLEARANCE <br /> EX GAS <br /> EX WATER POTHOLE AND RESTORE MAINTAIN 24" MIN ENGINEER: AB <br /> TO STANDARDS I CLEARANCE <br /> MAINTAIN 24" MIN .� DRAWN BY: PS <br /> CLEARANCE EX WATER POTHOLE AND RESTORE <br /> REVISIONS <br /> POTHOLE AND RESTORE MAINTAIN 24" MIN TO STANDARDS o DESCRIPTION INITIAL <br /> TO STANDARDS CLEARANCE I NOTETOEPITSD GNE <br /> ANY E DUGGTS DUG NEXT TO DRIPLINE OF AN EXISTING TREE <br /> POTHOLE AND RESTORE r TO BE DUGGED USING HYDRO VACCUUM EXCAVATION. <br /> TO STANDARDS s CAUTION!! <br /> ANY DISTURBANCE TO INFRASTRUCTURE WITHIN 15 FEET OF <br /> / ✓ ADA RAMP WILL REQUIRE ENTIRE RAMP TO BE REPAIRED IN <br /> 3829 COLBY AVE I ACCORDANCE WITH ALL REQUIRED ADA STANDARDS AND <br /> /Q—III/� I � SPECIFICATIONS. <br /> A. I ALL TELECOM UTILITY LOCATIONS ON PRINT ARE BASED ON <br /> C/] I FIELD SURVEY AND OBSERVATIONS.LOCATIONS MAY NOT BE <br /> ACCURATE OR COMPLETE. EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT <br /> w THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE <br /> CC > CONTRACTOR TO PLACE UTILITY WITH A MINIMUM OF 36 PROPERTY OF MCI COMMUNICATIONS SERVICES,INC..BOT <br /> BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT B <br /> INCHES OF COVER WHEN UNOBSTRUCTED.CONTRACTOR TO o, OR USED FOR A <br /> Q MAINTAIN 24 INCHES OF SEPARATION FROM OTHER UTILITIES. WITHOUT SPECIFIC WRITTEN PERMIsslorv. "v PURPOSE <br /> DEPTH TO BE ADJUSTED ACCORDINGLY. <br /> ml I UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON SCALE <br /> O DOCUMENT RESEARCH AND FIELD EVALUATION. THE <br /> I INFORMATION MAY NOT BE ACCURATE OR COMPLETE.IT IS HORIZONTAL: 1"=20' <br /> U <br /> THE CONTRACTOR'S RESPONSABILITY TO PHYSICALLY <br /> 3830 COLBY AVE LOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES VERTICAL: N/A <br /> WITHIN CONSTRUCTION PATH. <br /> ALL INSTALLATIONS MUST COMPLY WITH MINIMUM <br /> vn I I HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES. <br /> SHEET: C-14 <br />