My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1610 106TH PL SW A,B 2024-11-08
>
Address Records
>
106TH PL SW
>
1610
>
1610 106TH PL SW A,B 2024-11-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2024 11:55:56 AM
Creation date
10/14/2024 11:26:33 AM
Metadata
Fields
Template:
Address Document
Street Name
106TH PL SW
Street Number
1610
Unit
A,B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADDRESS NOTE, <br /> ADDRESS NUMBERS SHALL BE <br /> A MINIMUM 4"HIGH WITH A Report <br /> MINIMUM STROKE WIDTH OF 1/2" <br /> AND BE ON A CONTRASTING <br /> BACKGROUND PER IRC 319.1 <br /> swwe.wa <br /> NOTES <br /> — — — — — — — — — — — — — — _ u+, ear .",ybar o.eee..e <br /> — — — — — — — — MAX HEIGHT 1. ALL WOOD EXPOSED TO WEATHER SHALL BE <br /> PRESSURE TREATED OR CEDAR. copynab�211-1111-11zo23 riem <br /> — — — — — _ _ _ 2. CAULK AND SEAL ALL WINDOW/DOOR <br /> — <br /> _ AND EXTERIOR ENVELOPE PENETRATIONS. <br /> 12 — — — — — — — — RIDGE 3. GLAZING PER STATE ENERGY CODE. <br /> 4 12 4. SEPERATE PERMITS ARE REQUIRED FOR FENCES, <br /> Q4 PLUMBING,MECHANICAL,AND ELECTRICAL FOR PERMIT: <br /> 6 WOOD SIDING ANDWALPROTECTION FROM CLF IS REQUIRED <br /> LIESS THAN 2" B2401-013 <br /> ABOVE CONCRETE STEPS,PORCH SLABS,PATIO - <br /> - — — SLABS,AND SIMILAR HORIZONTAL SURFACES -- -- <br /> UPPERTOPPL_/1 EXPOSED TO THE WEATHER. <br /> L�BOARD AND BATTEN 6. REFER TO ALL ELEVATIONS FOR TYPICAL NOTES. <br /> SIDING-iX3 BATTENS <br /> BOARD AND BATTEN 7. S.G.=SAFETY GLASS <br /> O 18"O.C.W/PLYWOOD SIDING X BATTENS _ <br /> OR HARDI-PANEL BEHIND @ i6"O.C.W/PLYWOOD <br /> p d p G p G p G OR HARDI-PANEL BEHIND GENERAL NOTES O <br /> 6"EXPOSED <br /> HORIZONTAL SIDING dd1. ALL CONSTRUCTION PER APPLICABLE CODES AND <br /> 20 SF 205E 305E WEXPOSED ORDINANCES.20181RC,UPC,WSEC,IFC. <br /> HORIZONTAL SIDING 2. DVERIFY ALLISCREPANCIES <br /> DIMENSIONS T JOB SITE.BRING <br /> 5/4 X4 CORNER o <br /> 1 5/4 X4 CORNER DISCREPANCIES TO THE ATTENTION OF OWNER/ <br /> — — — 4 — 1 AND/OR DESIGNER. <br /> UPPER SUB FLR.. N 3. MAOWNERMANUFACTURER(S) <br /> VERIFY WITH <br /> FRAINDOWMER <br /> SIZER S AND <br /> BEFORE <br /> �7 START OF CONSTRUCTION. <br /> WRH FRAMER BEFORE <br /> _ — MAIN TOP PL START OF CONSTRUCTION. <br /> 4. ONE WINDOW PER BEDROOM SHALL MEET au <br /> EGRESS CODE <br /> 5. SKYLIGHT GLAZING PER I.R.C.2018. <br /> \ \� ® ® � 0 ® ® FE ® � D � D ® ® ® ® ��� 6. DRAWINGS <br /> MANUFACTURERSToOWNER <br /> AND FRAMER. REVIEW <br /> AND APPROVE BEFORE FABRICATION. <br /> (S.G.) ❑ ❑ ❑ ❑ ❑❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 15 SF o 7. OWNER WILL VERIFY ELECTRICAL AND HEAT <br /> (S.GJ LAYOUTS WITH INSTALLER BEFORE INSTALLATION. <br /> BRICK OR STONE VENEER ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ <br /> STALL PER MFD. <br /> 8. ALL EXTERIOR WARM WALLS TO BE 2 x 6 STUDS <br /> PE TALL PTIONS _ BRICK OR STONE VENEER @ 18"O.C.TYPICAL. <br /> INSTALL PER MFD. <br /> SPECIFICATIONS <br /> MAIN SURFER TYPICAL UNIT <br /> — — [ SQUARE FOOTAGE'S: <br /> [l —r — — — — � LZ`TON <br /> 15'-6"GARAGE DOOR(LESS THAN 50%PER19.09) S SEEICGRADE FORPR MAIN FLOOR 880 S.F. rn..e KLP HOMES <br /> 1 UPPER FLOOR 1,340 S.F. Ip� <br /> "✓0 .gin 31'-6"DWELLING UNIT FRONTAGE <br /> C TOTAL 2,220 S.F. <br /> ' FRONT ELEVATION <br /> $ME: 1/,r V_O" TRANSPARENCYREQ IREM NTSP R1908 GARAGE 400 S.F. <br /> CyTF�.F Sa ERETT <br /> 44 <br /> FRONT ELEVATION WALL AREA:5SF TOTAL 2,620 S.F.15%REQUIRED TRANSPARENCY:82 SF Fale!N. <br /> PROVIDED:85 SF <br /> ATTIC VENTILATION: <br /> VENTED BIRD BLOCKING AND GABLE <br /> — — — — — — — — — MAX HEIGHT END VENTING IS NOT ALLOWED WHEN <br /> THE EXTERIOR WALL IS 5'OR LESS <br /> FROM THE PROPERTY LINE OR WHEN <br /> - THE EAVE OR OVERHANG IS LESS <br /> — — — — — — - THAN 5'FROM THE PROPERTY UNE. <br /> — — — — — — — — <br /> V IT IS THE BUILDERS RESPONSIBILITY TO ASSURE THAT AL <br /> ARCHITECTURAL PROJECTIONS,INCLUDING DECKS,LANE <br /> EAVES AND FIREPLACES ARE ACCURATELY SHOWN ON TI <br /> SITE PLAN <br /> UPPER TOP PLC PROJECTIONS BEYOND EXTERIOR WALL <br /> V SHALL NOT EXTEND MORE THAN <br /> INTO REQUIRED YARD,NOR 6'INTO <br /> ❑ ❑ ❑ FRONT YARD <br /> Permit#: B2401-013 REVISED PLANS <br /> Site6r:ress: BR�� <br /> APPROVED E ESTATES NW LUC <br /> Office of Community,Planning d Economic Deyelommi Apo.Date: 1/7/2024 <br /> UPPER SUB FLR.-� PLANNING DEPARTMENT Permit Type: RESIDENTIAL BUILDING <br /> Z7 Subtype: NEW DUPLEX(2 DWELLING UNRS) <br /> MAIN TOP PL � Nam L//� 2 Description: NEW DUPLEX W/GARAGE BROOKSIDE <br /> ❑ ❑ V DATE:.L� ESTATES LOT 5) <br /> Reviewed BY: Date: <br /> *Office Set Job Site Set <br /> 0 <br /> O Re}RNrN <br /> — _ — MAIN SUB FL_ R � - •::;0;<i 0;' ae.N <br /> — — — — — — — — — — — R V _ ru"C'.Afefm <br /> — — — — — — BASE ELEVATION - 1/4" <br /> SEE SITE PLAN FOR PARCEL - - <br /> SPECRC GRADE ELEVATIONS <br /> `� T ELEVATION <br /> �/ SCALE 1/a 1 o ELEVATIONS <br /> Nwe No„bx <br /> Al APR 12 20211 <br /> CITY OF EVERETT <br /> Permit Services <br />
The URL can be used to link to this page
Your browser does not support the video tag.