My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1831 100TH ST SW A Plans 2024-11-12
>
Address Records
>
100TH ST SW
>
1831
>
Plans
>
1831 100TH ST SW A Plans 2024-11-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2024 3:14:37 PM
Creation date
10/15/2024 1:53:49 PM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
1831
Unit
A
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GRAPHIC SYMBOLS <br /> VDRAWING DRAWING DRAWING Al °J <br /> NUMBER-- NUMBER NUMBER = v � <br /> Al INTERIOR STREET-FACING FACADES OF RESIDENTIAL BUILDINGS 3 <br /> Al DETAIL SECTION A2 A701 Aa ELEVATION DESIGNED TO LOOK AS A SERIES OF BUILDINGS NO WIDER ¢'' <br /> A101 SHEET_____A101 SHEET THAN 50 FE T EACH(EMC 19.09.020(B)(2)) <br /> SHEET I NUMBER NUMBER A3 <br /> NUMBER 32' <br /> Name LEVEL Room nameROOM NAME& DOOR TYPE <br /> Elevation NUMBER a a <br /> Al REVISION [A] WINDOW TYPE a <br /> 3 <br /> APPLICABLE CODES: ACCESSIBILITY REQUIREMENTS: d <br /> ALL CONSTRUCTION SHALL CONFORM TO THE FOLLOWING None applicable per the scoping requirements of the <br /> APPLICABLE CODES®ULATIONS: Federal Fair Housing Act or International Building Code _ - <br /> (IBC).ANSI A117.1 does not establish scoping. - <br /> o�d <br /> •2018 International Residential Code it <br /> •Washington State amendments to the IRC,Chapter 51-51 WAC Section R320.1 of the 2018 IRC defers to IBC chapter 11 w u <br /> •2018 International Fire Code with statewide amendments for R-3 occupancy; 1 _ <br /> •2018 Washington State Energy Code IBC1107.6.3 allows reduction of Type B dwelling unit <br /> •2020 National Electrical Code requirement per section 1107; , I, w <br /> •Snohomish County Municipal Code 1107.7.2 exempts multistory dwelling units without <br /> elevator service from Type B requirements. See also <br /> ICC IBC commentary for section 1107.7.2. <br /> BUILDING CODE ANALYSIS: <br /> MECHANICAL,PLUMBING& <br /> IRC SECTION R302 ELECTRICAL NOTES: I 11'"2 1 <br /> PILASTERS&RECESSED ENTRIES PROVIDE HORIZONTAL <br /> Exterior Walls: 1-HR Rated when 3'separation GENERAL NOTES ARTICULATION AT<25' <br /> (EMC 19.09.020(B)(1)&19.12.040(B)) <br /> Projections: 1-HR Rated underside when 2'to<3' 1. Detailed mechanical,plumbing and fire protection 1\DESIGN STANDARD <br /> design&component selection shall be provided by S-FRONT <br /> separation -� 3/32"=V-0" <br /> Dwelling Unit Either a double wall consisting of(2)1- the mechanical and plumbing contractors on a design- <br /> separation walls: HR rated walls OR a 2-HR Rated build basis. Contractors shall be responsible for <br /> Common wall(1-HR if sprinklered)per obtaining any required permits. <br /> IRC R302.2.6 exception 5,no plumbing 2. All appliances and equipment shall be approved by a STREET-FACING FACADES OF RESIDENTIAL BUILDINGS <br /> or ductwork inside party walls,rating nationally recognized testing lab. DESIGNED TO LOOK AS A SERIES OF BUILDINGS NO WIDER <br /> shall be continuous the full length of 3. All piping and ducting shall be run in concealed THAN 50 FEET EACH(EMC 19.09.020(B)(2)) <br /> party wall&from foundation to spaces. Provide cleanouts,balancing valves and the LLI <br /> underside of roof sheathing like in accessible locations. <br /> 4. HVAC ducts penetrating one-hour rated assemblies U <br /> Garage Separation: 20 min.door with self closing device, shall be minimum 26ga galvanized steel. z <br /> penetrating ductwork shall be 26ga min. 5. Party walls between individual resident units shall not LLI Q <br /> Separation from adjacent space.1/2" contain plumbing or mechanical equipment,ducts or Q _ <br /> GWB vents in the cavity of the common wall. WEATHER PROTECTION AT J <br /> Separation from habitable rooms - PIUBLIC STREET-FACING 0 a <br /> above:5/8"Type'X'GWB PLUMBING NOTES FACADES,3'M120(A))IN.IN DEPTH <br /> (EMC 19AY U C <br /> G <br /> Fireblocking: Vertically at ceiling&floor levels 1. Showers&kitchen sink faucets shall be rated at 2.5 - 0 <br /> Horizontally at 10'max. gpm flow or less(RCW 19.27.170). - 46 SQ.FT.FRONT PORCH <br /> vertical&horizontal void intersections 2. Toilets to be limited to 1.6 gal per flush(RCW --- U <br /> Openings around vents,pipes,ducts,& 19.27.170). -- --_- ENTRANCE <br /> wires 3. Lavatory faucets shall be rated at 2.5 gpm flow or THE MAIN ENTRANCE MUST <br /> less(RCW 19.27.170)at dwelling units less than __ OPEN ONTO AN <br /> 1,500 conditioned square feet,and shall be rated at <br /> IRC SECTION R307 1.00 gpm flowor less(Per WSEC table R406.2 option UNENCLOSED PORCH THAT <br /> 5a)at units larger than 5,000 conditioned square feet. ___ IS AT LEAST 36 SQ.FT.IN <br /> Water Closets: 15"from face of wall to q. Insulation for hot water pipes shall have a minimum - AREA.(EMC 19.08.050(B)(2)) <br /> centerline min.,21"front clear thermal resistance(R-value)of R-3 per WSEC - -- <br /> Floor space min. R403.5.3. LWIJL - ONE PRIMARY ENTRANCE <br /> Lavatories: 21"fro nt clear floor space min. 5. Water heaters shall be secure to framing w/(2)galv. L MIN.ORIENTED TOWARD li, <br /> seismic straps. STREET,AND AT GRADE w <br /> 6. Water heater pressure relief valves shall be plumbed EMC 19.08.050 B 3 C))Showers: 24"front clear floor space min. ( ( )( )( <br /> to exterior. <br /> 7. All electric water heaters in unheated spaces or on c U <br /> IRC SECTION R308 concrete floors shall be placed on an incompressible, < o J <br /> insulated surface with a minimum thermal resistance <br /> Safety Glazing When in fixed or operable panels of R-10 per WSEC R403.5.5. 2 DESIGN STANDARDS-SIDE s <br /> required: of doors 3/32"=1'-0" <br /> When within 24"of door swing MECHANICAL NOTES (1) <br /> When all of the following are met EVERETT MUNICIPAL CODE ANALYSIS: Ud <br /> pane greater than 9 SF, 1. Source specific fans which vent to building exterior 7 2 O <br /> top more than 36"AFF, <br /> bottom below 18"AFF, are required as follows: L N <br /> &walking surface within <br /> baths&powder rooms: CHAPTER 19.08- O w <br /> U <br /> 36" so cfm laundry room:oom: w;min.z.s dm watt efficacy RESIDENTIAL USES AND DEVELOPMENT o <br /> When included in a guard or railing Y U <br /> When adjacent to wet surfaces 105 cfm,v.t.o.;min.2.8 cfm/watt efficacy STANDARDS z Q <br /> When adjacent to a stair,ramp,or kitchen range: U 0- <br /> landing 100 cfm,v.t.o.;min.2.8 cfm/watt efficacy W <br /> CHAPTER 19.08.050 m <br /> 2. Whole House Ventilation. Installer shall be <br /> IRC SECTION R309 responsible for the design and installation of an FRONT PORCH&ENTRANCE REQUIREMENTS -AII public street-facing facades <br /> intermittent whole-house ventilation system include a main entrance that opens onto an unenclosed porch <br /> Garage Floor: Noncombustible material, complying with the requirements as prescribed in <br /> Sloped to drain towards section M1505.4 of the 2018 International Residential <br /> vehicle entry doorway Code as amended by Washington State.System CHAPTER 19.12- <br /> shall utilize whole house ventilation using exhaust BUILDING FORM AND DESIGN STANDARDS <br /> N fans per section M1505.4.1. <br /> IRC SECTION R310 a. System shall provide both manual control and <br /> Emergency Opening not more than 44"AFF automatic control,ie.24 hour clock timer <br /> Escape Openings: 5.7 Sq.FA min b. System shall operate at least two hours out of CHAPTER 19,12,040 <br /> c 24"Tall,20"Wide opening min. every four. <br /> L c. At the time of final inspection automatic A)VERTICAL ARTICULATION-Street-facing front and side elevations include - <br /> control shall be set to operate the whole- cantilevers at the 2nd floor and changes in materials to create a distinct'base'and n <br /> IRC SECTION R311 house fan according to the schedule used to <br /> � calculate the whole house fan sizing. <br /> middle';gable roof forms tuck into the main roof form to create a distinct'top'. <br /> Egress door: Min.1 door with 32"clear width J. Installer to provide manufacturer install& <br /> Hallways: T min.clear width operating instructions B)HORIZONTAL ARTICULATION-Changes in materials and projecting bays are S <br /> r Stairways: 3'min.clear width+6'-8"clear ht. 3. All exhaust fans shall have a tight fitting back draft utilized to create horizontal articulation,with street facing facades broken into �I <br /> 0 7-3/4"riser max.,10"tread min. damper. groupings less than 50'In length. a <br /> Handrail 1 side minimum 4. All exhaust openings shall terminate not less than <br /> 1 T-0"from operable windows and doors,gravity air Cl FACADES LONGER THAN 100'-Vertical and horizontal articulation provided as <br /> IRC SECTION R314 intakes and property lines per section M1504.3 described above. <br /> °'JOB NO.: <br /> Smoke Alarms: At every sleeping room, 22205 <br /> outside sleeping areas and D)D)B�NK WALL STANDARDS STANDARDS-Street-facing ground floor walls incorporate <br /> at every story windows,doors,and changes in material pattern and color to mitigate blank walls. PLOT DATE <br /> interconnected on line ELECTRICAL NOTES <br /> voltage with battery E�EXPOSED FIRE WALL STANDARD WALL STANDARD-No exposed firewalls are proposed. 8/4/202310:4421 AM <br /> backup 1. A minimum of 90 percent of permanently installed <br /> lamps in lighting fixtures shall be high efficacy lamps `.'DATE: O6/06/2023 <br /> IRC SECTION R315 per WSEC R404.1. F)EXTERIOR BUILDING MATERIALS-All cladding will be painted fiber cement <br /> 2. Electrical&lighting design provided in these plans siding in a variety of styles,patterns and colors. r.SCALE: As indicated <br /> oCarbon Monoxide Outside sleeping areas are conceptual only. It shall be the sole responsibility DRAWN: ME <br /> Alarms: and at every story of the Contractor to select fixtures and document CHAPTER 19.12.120 CHCKD: TM <br /> compliance with energy code requirements. <br /> FIRE SPRINKLERS: WITHER PROTECTION PROTECTION-Facades fronting a public street have unenclosed, BLDG. SHEET No.: <br /> m covered porches that are 3'deep and 8'high per EMC Table 12-4 <br /> h Building to be fully sprinklered per IRC <br /> d appendix Q IRC section P2904/NFPA 13d C n 02 <br /> U <br />
The URL can be used to link to this page
Your browser does not support the video tag.