Laserfiche WebLink
WINDOW SCHEDULE ° <br /> NOM NOM rn a a <br /> Do <br /> W w WIDTH HEIGHT NwLL, ` <br /> :� <br /> O " LL 3 W Z U � <br /> 3 <br /> 1 2 3 4 A XO SLDR e G e G PVC .-I Y. 3 Q <br /> B XO SLDR e 0 e 0 PVC E <.2 Y. / <Al2 C cAseraeRY 2 e e 0 PVC <0.n ne s <br /> CC PICT. e 0 e 0 PVC <G.N No 2 <br /> EE XO SLDR a 0 s 0 PVC <0.2r Yn oss/ 1 <br /> EMPENEO <br /> 4 o Soo a o e a PP VC <0.n Y. a <br /> S Plc 1 2 2 3 e PVC <G.N NG 9 <br /> 1 I-- <br /> E A18 `t <br /> UNIT PLAN'B' UNIT PLAN'B' UNIT PLAN'B' <br /> 48'-2" o <br /> m <br /> 00 <br /> 12'-1" 4'-0° <br /> 2'-0" 12'-1" 1'-11" 4'-0" 12'-1" a�v <br /> dd <br /> 6'-10" 1..1. T-0" 6'-10" 8'-2" -0" 3'-O" <br /> WINDOW NOTES: <br /> A22 1.)Provide insect screens at all operable windows. <br /> 14 2.)Windows shall have an air infiltration rate of no more than <br /> 0.3 /SgFt - <br /> 3.)Quanticfmties are provided for convenience only.it shall be the <br /> sole responsibility of the contractor to verify all quantities provided. "' o <br /> DECK DECK DECK 4.)OBS=Obscure Glass . <br /> A <br /> ;ir <br /> ° 4 WALL TYPE SCHEDULE <br /> Eal Pair double dashed lines indicate walls required <br /> F S F ❑S �S ❑Q to be 1-HR fire resistance rated per assembly <br /> WP-5512,see sheet Alp. <br /> RwWen SN"eub <br /> 15'-2318" 15'-23/8" 15'-23/8" <br /> KEYNOTES: <br /> LIVING LIVING LIVING <br /> ELEC.HIGH EFFICIENCY WATER HEATER: <br /> PRESSURE RELIEF TO EXTERIOR,PROVIDE ADJACENT <br /> 3"MIN.STEEL BOLLARD WHEN LOCATED AT GARAGE. EE <br /> --U u °f SEE 3/A22. <br /> ELEC.WATER HEATER: Z <br /> 18 PRESSURE RELIEF TO EXTERIOR,PROVIDE ADJACENT Q <br /> 3"MIN.STEEL BOLLARD WHEN LOCATED AT GARAGE. J <br /> w C u SEE 3/A22. <br /> 12 <br /> O GARAGE DOOR:SELF-CLOSING 20 MIN.SMOKE& <br /> a ry ? DRAFT CONTROL DOOR W/TYPE'S'FIRE RATING <br /> 3 3 LABEL.W 2X10 GARAGE WRAP AT ALL DOUBLE SHEAR <br /> WALLS. O <br /> O HANDRAIL AT STAIRS:FINISHED WOOD HANDRAIL, O <br /> OVAL OR LOAF PROFILE,MOUNT 34"-38"ABOVE STAIR J <br /> P NOSING,1.1/2"MIN,FROM FACE OF WALL,RETURN TO <br /> 17 17 17 WALL AT ENDS. <br /> E Al2 1 _ RISERS RISERS RISERS <br /> R:7.7/16" R:7-7/18" R:7-7/1'. qO SHOWER: <br /> - T:10" T:10" ------ T:10" 3 EA12 SINGLE PIECE FIBERGLASS SHOWER ENCLOSURE. Z <br /> _-_-__ FRAMER TO VERIFY ROUGH OPENING SIZE,FURR IF N <br /> l5 a DINING DINING e 5 5 DINING NECESSARY TO PROVIDE CORRECT WIDTH. <br /> A J <br /> MINISPLIT INDOOR/OUTDOOR UNIT:INVERTER DRIVEN <br /> v y. <br /> °i 12 12 w 12 SINGLE ZONE DUCTLESS MINI-SPLIT HEAT PUMP,16 <br /> m I m <br /> SEER MIN. <br /> J 1. <br /> TUB/SHOWER 60"x30"SINGLE <br /> LE PIECE FIBERGLASS <br /> 8 <br /> "CI T U <br /> UB/SHOWER ENCLOSURE <br /> _ x SHOWER:38"x 38"SINGLE PIECE FIBERGLASS I 1 j <br /> o '�•• it y 4 ? '� O SHOWER ENCLOSURE.FRAMER TO VERIFY ROUGH <br /> OPENING SIZE,FURR IF NECESSARY TO PROVIDEcr <br /> 5'-103/4' 5'-103/4' a I! ; > 5'-103W' CORRECT WIDTH p (� <br /> I I I <br /> b <br /> °0 `Cr a O1 O WATER SUPPLY RISERIVALVE ASSEMBLY 1 <br /> q-p SEE ALSO PLUMBING DRAWINGS <br /> A22 A17 1 R0 O�icO 1 A17 m w ? A17 1 ��O �'T( ycc <br /> WALL TRANSFER GRILL: v LQ Q <br /> 4'-10 3l4" w m 4'-10 3/4" 4'-10 3/4" �; O 6"X 18"TRANSFER GRILL REGISTER,LOCATED 4.5" 3 ' <br /> �� <br /> 5"/1'-0" ABOVE FINISH FLOOR AND ABOVE DOOR V) <br /> KITCHEN KITCHEN KITCHEN <br /> • 10 WASHER/DRYER:DRYER VENT INSTALLED IN WALL. Z <br /> N ^i 11 BATH#3: O JU (1 <br /> 38"X 38"SHOWER(KEYNOTE 7)ROUGH OPENING <br /> [EE m 17 3 ? 3 A 17 3 0l 36 3/4"TYP.FOR ALL UNITS LOCATED AT PARTY O LL <br /> BB ITEMPERE WALLS. ` Q <br /> BATH BATH BATH 36"ROUGH OPENING TYP.FOR ALL END UNITS WITH U d <br /> #3 a' 6' #3 #$ a•Ds'e SHOWER LOCATED ON EXTERIOR WALL. <br /> el OLD IF LD BI OLD Uj <br /> P P P FRAMING NOTES: m <br /> 1'-10" <br /> _ 1.)ALL DIMENSIONS ARE TO FACE OF FRAMING 8 <br /> ��- CENTERLINE OF OPENINGS UNLESS NOTED OTHERWISE. <br /> 2.)ALL NON-ORTHAGONAL WALL ANGLES ARE 45" <br /> ❑A A UNLESS NOTED OTHERWISE. <br /> N 3.)DOORS LOCATED ADJACENT TO A PERPENDICULAR <br /> N TPARTITION AND NOT LOCATED BY DIMENSION ON PLANS, <br /> 9'-8" 8'-6" 8'-5" 9'-7" 9'-8" 6'-5" INTERIOR ELEVATIONS,OR DETAILS SHALL BE 3"FROM <br /> o FACE OF STUD TO EDGE OF DOOR ROUGH OPENING. <br /> Y <br /> E s <br /> 3'.0' 18'-1" 18'-0" 18'-1" y <br /> of <br /> O N a <br /> � 48'-2" •lt <br /> e <br /> e <br /> I o O <br /> `o <br /> ^�JOB NO.: <br /> 22205 <br /> N .I <br /> 1 2 3 4 J PLOT DATE <br /> m WM023 10:50:09 AM <br /> 2 - <br /> DATE: 06/08/2023 <br /> SCALE: As indicated <br /> o EA12 „DRAWN: MB <br /> o ,-",CHCKD: TM <br /> BLDG. SHEET NO.: <br /> .I EA0' SECOND FLOOR PLAN _ E A07 <br /> 1 1/4"=1'-0.1 0' 2' 4' 8' 16 <br /> U <br />