Laserfiche WebLink
PHASING LEGEND <br /> EXISTING CONSTRUCTION TO REMAIN <br /> __= ITEMS TO BE DEMOLISHED <br /> NEW CONSTRUCTION <br /> A C <br /> A3.2 A3.2 <br /> 2a'6t PLAN GENERAL NOTES <br /> 9'3"t 1'•2 9'3't Y2" 1T4" 1 '3" 21'-10' <br /> 1. WALLS,CEILING AND FLOOR INSULATION;AND WINDOW AND <br /> DOOR GLAZING TO BE IN ACCORDANCE 2018 WSEC.SEE SHT. <br /> 102 103 A0.1. <br /> J. t — — — — t <br /> 2. TEMPERED SAFETY GLAZING TO BE PROVIDED PER 2018 IRC <br /> SECTION R308.4;SEE ELEVATIONS OR WINDOW SCHEDULE FOR <br /> LOCATIONS. <br /> 20'-34 6-10"i 24'-9•t 3. INSTALL 11 oV SMOKE DETECTORS,INTERCONNECT W/BATTERY <br /> 2 BACKUP,PER 2018 IRC WA STATE AMENDMENTS SECTION R314; <br /> 101-8" g-�. Z-3- 2'5Y2"1'4' 51 ,g-2• 8'-1" aD SEE PLANS FOR LOCATIONS. <br /> L OP RCH 4. INSTALL CARBON MONOXIDE DETECTORS PER 2018 IRC WA <br /> + EG $$O EG $$O STATE AMENDMENTS SECTION R315;SEE FLOOR PLAN FOR <br /> 19'-"x 16-r LOCATIONS. <br /> _ J J _ J S 100 O® O N 5. INSTAL WHOLE HOUSE VENTILATION FAN PER 2018 IRC WA <br /> - STATE AMENDMENTS SECTION M1507.3:SYSTEM SHALL PROVIDE <br /> 16 — 204 I MIN.CFM PER TABLE M1507.3.3(1). <br /> GARAGE 1D 24.5 2" 10'-2^ <br /> ai 23'-6"x 23'-5" L-42 <br /> � � B. ALL EXHAUST FANS TO SE LOCATED AND SIZED PER 2018 IRC <br /> WA STATE AMENDMENTS TABLE Ml507A. <br /> F?T?12M-ffi <br /> 14 BED#5 <br /> 1172'x 12'-0" n 7. FAN NOISE RATING TO BE 1.5 BONE OR BETTER <br /> I LIVI G RO H I r <br /> I� �"x+5 ❑ +4 2p2 + O PLAN KEYNOTES <br /> BCD 8 1Q. 110V COMBINATION SMOKE&CARBON MONOXIDE <br /> g v `®SCD 201 —T 203 ®® DETECTOR INTERCONNECT W/BATTERY BACKUP <br /> 1a O OTYR <br /> L— 0 ROOF LINE ABOVE OR WALL BELOW. <br /> m J 1 SCpr , 205 3 03. 90 CFM,LE SONO BATH ENERGY STAR FANS WITH 4" <br /> 16'-9' T-l' 4'-W !4 5'3" 5'-0'§ f 5-3' O T-8' - SMOOTH DUCTING.(MIN.90 CFM FOR CONTINUOUS <br /> —7 OPERATING WHOLE HOUSE FAN IN ACCORDANCE WITH <br /> -- -------� C-- �__ f 7—BATH#2 r I SEC.M1507.3.3(1) <br /> -- 8 —7'-0"x 9-10 <br /> ++ IyEF ® U.L.APPROVED DIRECT VENT GAS BURNING FIREPLACE <br /> W 15 I Y A'l'+Tm 208 3 y Q5. DRYER-VENT TO OUTSIDE <br /> Cr O z © EXHAUST TERMINATION-IN ACCORDANCE WITH IRC <br /> W 211 6-2 x 1 z in } M1507.3.4.4 <br /> BEDI�bOM#3 LAUND Y g <br /> 9'-1 x 11'-Tx 11'-7^ - IBATH#1 T-3'x 11,7• DINING ROOM SCD Q PROVIDE EMERGENCY ESCAPE OPENING IN ALL <br /> L SLEEPING ROOMS MIN.24"HIGH X 20"WIDTH AND 5.7 S.F. <br /> 16'-0"x 12'-0" <br /> D f+ CLEAR OPEN AREA IN ACCORDANCE WITH IRC R310.1 <br /> 10'S• 7,-9" '7 16,-0" r 5.�. I 13,-1. <br /> 22"X 30"ATTIC ACCESS-WITH MIN.UNOBSTRUCTED <br /> B SCD 3 O 5 KITCHEN 9 O O N1 , I HEADROOM ABOVE HATCH OF 30"-EXISTING VERIFY <br /> 2 I 212 18'-0'x 1T3' 401 BCD ,2 RANGE WITH 300 CFM HOOD <br /> 14 I 6 215 O 0. 7 <br /> 218 h 8 1 O 10 5/8'TYPE-X GWB ON ALL WALLS&CEILING AND AROUND <br /> 4 — -- L— — ------_]-- __�__�—_--- —}---- --JL] �I �, -- ----__— ALL BEAMS AND POSTS. <br /> '-11" 4'-0" 8'-3" 11. SOLID CORE DOOR W/SELF CLOSER <br /> 1 SUI E <br /> I n�S D 12. TOWEL WARMER(NOT USED) <br /> a <br /> N q -- 13 5/8"TYPE X GWB UNDER STAIR <br /> 2+4 —— ——— 101 $G.1�+� q 00 209 14 ROD&SHELF <br /> 14 14 218 217 _ <br /> Sc 14 z13 ++ DOOR&WINDOW NOTES <br /> _ 3 <br /> S1C,'D11' T-10Y" 6�Y2" �7'-0' 8'-10" 1. SEE SHT.A0A FOR 2018 WSEC REQUIREMENTS;ALL <br /> EXTERIOR DOORS AND WINDOWS SHALL COMPLY. <br /> 2. SEE FLOOR PLAN FOR SLIDING/POCKET DOOR ACTIVE `^ <br /> DOOR PANEL LOCATIONS AND DIRECTIONS. v, <br /> b BEDROOM#2 BEDROOM#1 OUTDOOR ROOM I 3. SEE ELEVATIONS FOR OPERABLE WINDOW SASH <br /> DIRECTIONS. Z <br /> 11'-9' 12'-' <br /> 115"x 14'-8• 15'-9"x 15'-0' 4. ALIGN WINDOW AND DOORS HEADS-TYR O <br /> _ <br /> L _ -,p EG ss — — J AREA CALCULATIONS ~ <br /> < <br /> ❑ ❑ / �/ 4�-+Y2 8'-0' 6'-7Y2" LL <br /> (i `7 EXISTING FINISHED 1,731 S.F. <br /> m ro PROPOSED FINISHED 835 S.F. w <br /> _ TOTAL HEATED AREA 2,566 S.F. <br /> 13 EG $$`4 _ GARAGE 570 S.F. J <br /> — 12 EG SS Q <br /> 6,-4Yz 5,-6Y2" —6 "— — 6—r/2 z' —5 "_ s,o— + +e' J Z <br /> 12'-1" 12'5' iv-r 15'•10' 18'-9' L < <br /> 75ot PE L L E T I E R (+ S C H A A R z <br /> O <br /> z6gn oth Dr.NW,Suite B 4Stanwood,NVA 98zgz <br /> ww.pel letierschaar.com 36o-629-5375 0 <br /> 0 <br /> NOTE: Q <br /> ALL DIMENSIONS SHOW t TO ALIGN No.:xnooDc DRN:xxx CHKM <br /> WITH EXISTING CONSTRUCTION AND 0P 1P-ER.SCHAAR,L.La <br /> PROJECT TO BE VERIFIED IN FIELD <br /> NORTH <br /> O <br /> MAIN FLOOR PLAN <br /> i <br /> SCALE 1/4"=V-0" 0' 4' 8' T A1 . 1 O <br /> 3/15/2023 U <br /> W <br /> PERMIT DRAWINGS - MAIN FLOOR PLAN <br />