Laserfiche WebLink
TAG: EF-1 Page-A-e# <br /> Type U BCA • Non-overloading aluminum 11� /� <br /> wheel computer balanced r <br /> Belt Drive Centrifugal Upblast • Force ventilated motor <br /> Power Roof Ventilator compartment Isolated from <br /> airstream lit — <br /> • Variable pitch motor pulley <br /> B DIA. — . Adjustable hinged motor <br /> bracket with bolt belt <br /> tension adjustment <br /> INDUSTRIES • Weatherproof spun <br /> AMERICAN COOLAIR CORPORATION aluminum housing <br /> • NEMA Standard open drip- <br /> Accessories proof motors <br /> AID LOW LEAKAGE • Overlapping wheel/inlet <br /> venturi <br /> MOTORIZED • <br /> Built-in <br /> rease <br /> DAMPER(SIZE TBD) C D moval and water <br /> drain <br /> ND HP 460/3/601 SP ODP • Heavy duty self-aligning <br /> \ / pillow-block bearings with <br /> PFC1 Roof Curb cast iron housing <br /> • AMCA label for air and <br /> sound <br /> • UL Listed for Standard 705 <br /> or Standard 762(most <br /> I <br /> models) <br /> A SQ.I.D. <br /> 2" <br /> A B C D Dimensions in inches <br /> 46 62518 457I6 37112 unless otherwise noted <br /> Weight: 693 lbs. Tip Speed: 5,474 ft/min Outlet Velocity: 1,110 ft/min <br /> Fan Data Motor Data Accessories <br /> Qty Model No. CFM inWg RPM BHP MHP RPM VoltagelPh Hz Encl. PFC1 ND A/D <br /> 1 UBCA36PD8363 13,000 0.250 563 2.46 3 1,750 208/230/460V3PH 60 OPEN <br /> Sones LwA dBA dBA dBA Octave Band Sound Power(Lw) <br /> @ 5' @ 10' @ 20' 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz <br /> 17.6 79 68 62 56 87 90 83 73 69 66 61 54 <br /> Air Density:0.075 Ibs/ftA3 AMCA Licensed for Sound and <br /> 1.50 — — ........-3.00 Alr Performance <br /> ,. Power rating(BHP)does not <br /> �bi r' • Include transmission losses. <br /> ,';• 5 Bearing losses are included. <br /> #1C.�ily 1.25 .. •-:: ...__ 2. 0 Performance ratings do not <br /> mw -+-• Include the effects of <br /> irimirmusi appurtenances(accessories). <br /> Performa <br /> e shown <br /> r*ailinaT a* a too ..-.._.......- --- ...._.. ....... .... ...-_ .__..-. . .. ................. ....-.-.. .........-2.00 Installation Type'A': <br /> is <br /> Inlet, <br /> y �7 Free outlet <br /> **now.. <br /> •'" G • * The sound ratings shown are <br /> pgTsWnoaE.MI.. w ; I loudness values In <br /> Ei 0,F5-... _ ;.. _._.... •,.... .... ._... ... <... ......... ._.-1.50 hemispherical saes at 1.5 m(5 <br /> w ft.)In a hemispherical free geld <br /> S calculated per AMCA Standard <br /> 301. <br /> American Coolak Corporation certifies that 4' 0.50--. . -- - - ---- - - - --- 1,00 VaInstallation ues Typewn are for <br /> Type'A': Inlet <br /> the Type UBCA units shown herein are Free in <br /> licensed to bear the AMCA seal.The • <br /> hemispherical sons levels <br /> ratings shown are based on tests and 0 25 --__-- ---- --...._....,_--»....--,,,,^,,,,,,,,,,• _ _ --•.,.,,,,.,-_0,50 Sound ratings apply to sons <br /> w •_ <br /> procedures performed in accordance with -- -•"-" <br /> AMCA Publication 211 and AMCA -"-..-"' <br /> Publication 311 and comply with the �•%.'— '-�~ <br /> requirements of the AMCA certified Ratings 0.00 --. 0.00 <br /> Program. 0 2,500 5,000 7,500 10,000 12,500 15,000 <br /> Volume Flow Rate{CFM) <br /> Notes: UL762 <br /> Project: JAMECO Engineer: COMFORT MECHANICAL <br /> Location: KENT Contractor: COMFORT MECHANICAL <br /> Submitted By: Date: 7/23/2021 <br /> Approved By: Date: <br /> FanSelect 6-December 2020 ver.6.7.0 <br />