Laserfiche WebLink
victaulic.com <br /> • <br /> 4.0 DIMENSIONS • <br /> Style 009N <br /> ID <br /> Ij II 2 iy lri ,Tr <br /> Style 009N Pre-Assembled Style 009N Joint Assembled <br /> (Push On Condition) <br /> Bolt/Nuts L Dimensions Weight <br /> Pre-assembled <br /> Actual Maximum Maximum Allow. (Push On Condition) Joint Assembled <br /> Nominal Outside Working End Pipe End - Approx. <br /> Size Diameter Pressure3 ' Load3 Separation Qty. Size X Y X Y Z (Each) <br /> inches inches psi L. lb inches inchesT inches inches inches inches inches lb <br /> II <br /> i` II11 - ...,,, nra IN 11111I IIII11 I 111111 III111 Tom ni,.. 1In n _- ny "- <br /> 1 Y4 1.660 365 790 0.10 3/&x 2 3.13 5.00 2.75 5.00 2.00 1.4 <br /> 32 42.4 2.517 3514 2.54 2 M10 x 2 79 127 70 127 _ 51 _ 0.6 <br /> ,11/2 1.900 365 1035 0.10 2 3/e x 2 3.38 5.13 3.00 5.13 2.00 1.5 <br /> 40 48.3 2517 4604 2.54 M10 x 2 I 86 130 76 130 51 0.7 <br /> 2 2.375 365 1616 0.12 3/8 x21 4.00 5.63 3.50 5.63 2.00 1.9 <br /> 50 60.3 2517 7193 3.05 2 M 10 x 21/2 102 143 89 143 51 0.9 <br /> 2 Y2 2.875 365 2370 0.12 3/a x 21/2 4.50 6.13 4.00 6.13 2.00 2.1 <br /> 65 73.0 2517 10542 3.05 2 M 10 x 2% 114 156 102 _ 156 51 1.0 <br /> 76.1 mm 3.000 365 2580 0.12 2 %x 21/2 4.63 6.00 4.13 6.13 2.00 2.1 <br /> 76.1 2517 11476 3.05 M10 x 21 118 152 105 156 51 1.0 <br /> 3 3.500 365 3512 0.12 2 %e x 21/2 5.13 6.75 4.63 6.75 2.00 2.3 <br /> 80 88.9 2517 15622 3.05 M10 x 21/2 130 171 117 171 51 1.0 <br /> 4 4.500 365 5805 0.17 %x 21 6.00 7.88 5.63 7.50 2.13 2.9 <br /> 100 114.3 2517 25822 4.32 2 M 10 x 21/2 152 200 143 191 54 1.3 <br /> 4.250 365 5175 0.17 3/8 x 21/2 5.63 7.38 5.38 7.38 2.13 3.1 <br /> 108.0 mm 108.0 2517 23020 4.32 2 M10 x 21/2 152 1.87 137 187 54 1.4 <br /> 41) D -""f` bJOi 11."1 .so. U.I/ /2A .I <br /> k /.Lb 7.La b./� j 7J L.L> a.0 <br /> 125 1 141.3 2000 39456 4.32 2 M12 x 3 184 235 171 j 232 57 2.3 <br /> 5.250 365 7897 0.17 Y x 3 6.63 9.00 6.38 9.00 2.25 4.8 <br /> 133.0 m m 133.0 2517 35106 4.32 2 M 12 x 3 168 229 162 229 57 2.2 <br /> 139.7mm 5.500 365 8667 0.17 2 1 x 3 6.88 9.25 6.75 9.13 2.25 4.9 <br /> 139.7 2517 38529 4.32 M12 x 3 175 235 171 232 57 2.2 <br /> 159.0 mm 6.250 365 11192 0.17 2 1 x 3% 7.88 10.00 7.38 9.88 2.25 5.6 <br /> j 159.0 2517 49753 4.32 M12 x 3 lAi 200 254 187 251 57 2.5 <br /> 6.500 365 12105 0.17 1 x 31/a 8.00 10.25 7.75 10.13 2.25 6.0 <br /> 165.1 mm 165.1 _ 2517 53813__ 4.32 2 M12 x PA 260 197 257 57 2.7 <br /> 6 1 6.625 365 12582 0.17 1/2 x 31/4 8.38 10.38 7.88 10.13 2.25 6.0 <br /> 150 1 168.3 _ 2000 44469 4.32 2 M12 x 3 1/4213 264 200 257 57 2.7 <br /> 216.0 mm 8.500 365 20712 0.17 2 %x 4 10.63 13.25 10.25 10.13 2.63 11.4 <br /> 216.0 2517 55968 4.32 M 16 x 4 270 337 260 257 67 5.2 <br /> 8 8.625 365 21326 0.17 5/e x 4 10.88 13.38 10.25 13.13 2.50 11.4 <br /> _ 200 219.1 1620 94863 4.32 2 M 16 x 4 276 340 260 333 64 5.2 <br /> 10 10.750 300 27229 0.25 7/a x 61/2 13.75 17.00 13.25 17.13 2.75 22.6 <br /> _ 250 273.0 2068 121121 6.4 2 M22 x 165 349 432 337 435 70 10.3 <br /> 12 12.750 300 38303 0.25 2 7/a x 61/2 16.00 19.00 15.50 19.13 2.75 27.6 <br /> 300 323.9 2068 170380 6.4 M22 x 1651 406 483 394 486 70 12.5 <br /> 3 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in <br /> accordance with Victaulic specifications.See the Listings/Approvals section of this publication for ratings on other pipe. <br /> 4 The allowable pipe separation dimension shown is for system layout purposes only.FireLock EZTM couplings are considered rigid connections and will not <br /> accommodate expansion or contraction of the piping system. <br /> 5 Number of bolts required equals number of housing segments. <br /> NOTES <br /> • When assembling FireLock EZT"1 couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For <br /> FireLock EZT^1 Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV <br /> EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009N couplings.IMPORTANT:Gaskets intended for the Style 009 <br /> or Style 009V couplings cannot be used with the Style 009N coupling.There is no interchanging of gaskets or housings between coupling styles. <br /> • Use Of Flushseal Gaskets For Dry Pipe Systems FireLock EZTM couplings are supplied with FireLock EZTM Grade"E"Type A gaskets.These gaskets include an <br /> 11111 integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic <br /> Flush-SealTM gaskets are not compatible and cannot be used with the FireLock EZTM couplings. <br /> • •10.64 7072 Rev I Updated 01/2017 ®2017 Victaulic Company.All rights reserved. <br /> victaulic.com 3 ✓ctaulrc° <br />