• • <br /> Mr. Carmelo N. Laviste <br /> CNL Design and Drafting <br /> Plan Check Number: B2101-048, First Building Review <br /> February 2, 2020 <br /> Comments <br /> 1. The project involves conversion of the Lower Floor to an adult family home (AFH). The <br /> checklist form, to be completed by the building inspector, was not included and should be <br /> submitted. Note that the applicant's form and the 8.5x1 floor plans have been received. The <br /> form ay be obtained at the following website: <br /> https://everettwa.gov/DocumentCenter/View/108/Adult-family-home-checklist-PDF <br /> 2. The building appears to include unpermitted work. The work should be shown as new <br /> construction in the plans, or it should be identified for demolition and returned to the previously <br /> permitted condition. Alternatively, documentation should be submitted substantiating that the <br /> work was performed with a valid permit. All new work is required to comply with current code <br /> requirements per Section R102.7.1(WAC), regardless of whether it is physically in-place. The <br /> plans may require notes to remove finishes to allow inspections per Section R109. See Sections <br /> R106.1.1 and R105.1. Unpermitted work appears to include but is not limited to: <br /> a. Canopies over the rear deck. <br /> b. Deck stairway and associated modifications to the deck framing. <br /> c. Guards for the deck stairway and around the deck opening. <br /> d. Coverings extending between the west wall and the fence line. <br /> 3. Handrails should be specified at all stairways per Section R311.7.8. <br /> 4. Section A and the Typical Wall Detail on Sheet A-3 specify a thermal break between the slab <br /> and foundation wall of R-5. The minimum thermal rating should be R-10. See WSEC-15 Table <br /> R402.1.1. <br /> 5. The Foundation Plan on Sheet A-3 shows new 4x8 headers. The headers should be provided <br /> with king and jack studs per Section R602.7.5. <br /> 6. Fasteners should be specified for all structural framing per Table R602.3(1). Providing <br /> references to this table in the drawings does not satisfy this requirement. <br /> 7. The new exterior door on the west side of the building should be provided with a landing per <br /> Section R311.3. <br /> 8. The drawings should include a note requiring all smoke detectors to be interconnected per <br /> Section R314.5. <br /> 9. All exterior doors should specify a maximum thermal rating of U=0.3. See WSEC-15 Table <br /> R402.1.1. <br /> 10.The ADH shower at the Lower Level Plan on Sheet A-2 should show a single continuous grab <br /> bar along the back wall. See Section R325.8.5.2. <br /> a Everett,WA 98201 425.257.8857 fax 3200 Cedar Street �.CJ 425.257.8810 , 1 everetteps@everettwa.gov <br /> `®� everettwa.gov/.- ••'ts <br /> Page 2 of 3 <br />