APPROVAL STAMPS
<br /> 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
<br /> A A
<br /> A
<br /> FA1.10
<br /> B
<br /> RISER
<br /> ROOM
<br /> Ca 'ww` 104
<br /> :ELECTRICAL 103 C ; D1_1 l/ SIEMENS
<br /> ROOM ,10V,AN,P
<br /> — — _ _ 4A,10V,AN,P C C C
<br /> WEST STAIR
<br /> D oo v V 15CD v 5cD V v scD p SIEMENS INDUSTRY,INC.
<br /> 15900 SE EASTGATE WAY
<br /> BELLEVUE,WA 98008
<br /> 425.507.4300
<br /> 800.952.6348(24-HR SERVICE)
<br /> 4 v,AN,P c
<br /> °_ LICENSE:CC #SIEME11919PP
<br /> E 4 ; E
<br /> .003 This drawing and the information and design application
<br /> M d 1 herein contained is the property of SIEMENS INDUSTRY,
<br /> 2A III INC. and is loaned upon the express condition that the
<br /> 3A,8V ABOVE FLOOR
<br /> ANP some be returned to SIEMENS INDUSTRY, INC. upon
<br /> request; all information herein contained shall be treated
<br /> as secret and confidential; no reproduction of this
<br /> C drawing or part thereof shall be made without the written
<br /> F C 2V 24k ' C C C I r consent of SIEMENS INDUSTRY, Incorporated.
<br /> ® 15CD 15CD V 15CD V 15CD V�
<br /> G G
<br /> ------------- ------------- ------------- ------------- ----------
<br /> F r
<br /> H H
<br /> o A,V,AN,P C 1V1-2-1 A,V,AN,P A,V,AN,P C ,AN,P C A,V,AN,P C
<br /> 5CD
<br /> L1.026 M 15CD 15CD M L1.027 e 1V1-2-8
<br /> ELEVATOR
<br /> MACHINE
<br /> L1.020 ELEVATOR ROOM IR z L1.01
<br /> u L1.005 R z 11.0 4 MACHINE awlL1.011 RM
<br /> A,2V,2AN L1.006 RM U ROOM L1.012 RM L1.023 2A
<br /> L1.007 R 2A 1p8 L1.013 RM A,V,AN,P
<br /> J L1.008 R 2A a o L1.014 RM
<br /> �' 2A
<br /> 3 .02 3 f
<br /> r
<br /> F1WEST K
<br /> .CD C 1V1--2 2A 30CD 1V1-2-5 C A' P2A2V,2AN,P WEST ° EAST STAIR a LOADING 2AN -9 1tfr LOBBY100
<br /> 0 2A,2V,2 ,
<br /> oC oC y
<br /> 5CD
<br /> 1V1 -3 15C 2A,2V,2AN,P CART
<br /> 1 2-4
<br /> M STORAGE M
<br /> UNISEX UNISEX
<br /> RESTROOM RESTROOM
<br /> 2 1
<br /> 102 101
<br /> 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 AGENCY REFERENCE
<br /> POWER INPUT POW INPUT
<br /> 1E5120VAC-60HZ 120VAC-60HZ BFP
<br /> (BY OTHERS) (BY OTHERS)
<br /> L1.001 L1.063
<br /> ER Z
<br /> °IV1 - 1V3< _
<br /> I 1.016 P SURGE PADS SURGE PADS D D M L1.019 a
<br /> FACU PAD51V2 1 17L1.018 RISER
<br /> A L1 L1.045
<br /> 4A,10V,AN,P ROOM 00 08/08/23 ISSUED FOR PERMIT ARK
<br /> A REV DATE REMARKS INTL
<br /> 4A,10V,AN,P I NO.
<br /> zu.002 04 I DRAwN: APK
<br /> CO) CHECKED: GIN
<br /> SHEET DESCRIPTION:
<br /> ELECTRICAL 103 NOTES FIRE ALARM SYSTEM
<br /> ROOM OV,AN,P I KEY NOTES:® LEVEL 1 FIRE ALARM PLAN
<br /> 1. ELEVATOR:
<br /> PRIMARY RECALL
<br /> E — — — — — — — — ALTERNATE RECALL JOB NUMBER:
<br /> HAT LIGHT 440P-360662
<br /> ELECTRICAL & RISER ROOM EXPAND VIEW SHUNT TRIP
<br /> o A SHUNT CONTROL CIRCUIT MONITOR
<br /> SCALE: 1/4" = 1 1-0-1 0 2 4 8 ADDRESS:
<br /> 2. HEAT DETECTOR SHALL BE WITHIN 2 FEET OF SPRINKLER HEAD. PROJECT NAME\
<br /> i
<br /> 3. ACCESS TO SMOKE AND HEAT DETECTOR(S)IN THE ELEVATOR SECURE SELF STORAGE-EVERETT EXPANSION
<br /> BROADWAY EVERETT SELF STORAGE
<br /> HOISTWAY SHALL BE PROVIDED FROM THE EXTERIOR OF THE 8407 BROADWAY
<br /> i
<br /> BUILDING.ACCESS HATCH SHALL BE FURNISHED BY OTHERS. EVERETT,WA 98208
<br /> 4. 24 VDC ELECTRIC BELL- PROVIDED BY OTHERS.
<br /> NORTH
<br /> 1 LEVEL 1 FIRE ALARM PLAN 5 DEVICES SHALL BE MOUNTED ON THE TOP OF THE HOISWAY NUMBED
<br /> NUMBER:
<br /> SCALE: 1/$„ = 1,_O,. 0 4' 8' 16' FA1 ■10
<br /> SHEET SIZE:ARCH El-30x42