My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8407 BROADWAY 2024-11-12
>
Address Records
>
BROADWAY
>
8407
>
8407 BROADWAY 2024-11-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2024 11:24:19 AM
Creation date
10/29/2024 9:59:58 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
8407
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
259
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
APPROVAL STAMPS <br /> 0.1 MANUAL PULL STATION DEVICE LOCATION DETAIL NOTIFICATION APPLIANCE LOCATION DETAIL �j PILOT RELAY WIRING DIAGRAM A SURFACE MOUNT TO STEEL STUD CABINET DETAIL <br /> I NOT TO SCALE--SEE APPLICABLE EQUIPMENT INSTRUCTIONS FOR ADDITIONAL INFORMATION 02 NOT TO SCALE--SEE APPLICABLE EQUIPMENT INSTRUCTIONS FOR ADDITIONAL INFORMATION 03 NOT TO SCALE--SEE THE INSTALLATION INSTRUCTIONS FOR ADDITIONAL INFORMATION 04 NOT TO SCALE--SEE APPLICABLE EQUIPMENT INSTRUCTIONS FOR ADDITIONAL INFORMATION <br /> CEILING Coil Current: Contact Ratings: POSITIONING FOR DIMENSIONS"A"AND"B" <br /> MOUNTED 33 mA @ 10 Vac 10 Amp Resistive @ 277 Vac SHALL BE BASED UPON THE LISTED <br /> FINISHED CEILING LINE C APPLIANCES 6" MIN 35 mA @ 12 Vac 10 Amp Resistive @ 28 Vdc CABINET MOUNTING HOLE LOCATIONS. <br /> 46 mA @ 24 Vac 480 VA Pilot Duty @ 240-277 Vac STATUS LED VERIFY WITH MANUFACTURER'S <br /> c� IN CORRIDORS, MAX 55 mA @ 30 Vac 480 VA Bollost @ 277 Voc INSTALLATION INSTRUCTIONS. o U <br /> WHERE APPLICABLE, MAX. 15' 28 mA @ 120 Vac Not rated for Electronic Ballast <br /> 100' UNOBSTRUCTED �� RIBUIC <br /> DISTANCE 13 mA @ 10 Vdc 600 Watt Tungsten @ 120 vac(N/0) 0 <br /> ADDITIONAL PULL STATIONS FROM END DISTANCE BETWEEN 15 mA @ 12 Vdc 240 Watt Tungsten @ 120 Vac(N/C) WHT BLK BLU U <br /> SHALL BE PROVIDED SO THAT APPLIANCES 18 mA @ 24 Vdc / p 4•16 GAUGE SLOT TRACK <br /> / OF CORRIDOR AUDIO ONLY 20 mA @ 30 Vdc 1/3 HP @ 120-240 Vac(N/0) (12oVacN/C o <br /> EXIT THE TRAVEL DISTANCE TO APPLIANCE 1/6 HP @ 120-240 Vac(N/C) 0 WITH 3/8-0 K63 WITH 3" <br /> AUDIO/VISUAL EMBED @ D O.C. 6., <br /> THE NEAREST PULL STATION WALL MOUNTED y 1/4 HP @ 277 vac(N/O) 0 MAX.@END <br /> APPLIANCES O OR VISUAL o Coil Voltaoe Input: WHT/BLU YEL <br /> MAX DISTANCE DOES NOT EXCEED 200'ON APPLIANCE 10-30 Vac/dc; 120 1/8 HP @ 277 Vac(N/C) (10-30 Voc/dc) C U #8 SMS WITH <br /> 5' FROM DOORWAY THE SAME FLOOR. vac 50-60 Hz STAND-OFF <br /> AUDIOVISUAL WASHER, <br /> OPENING WHERE OR VISUAL WHT/YEL ORG TYPICAL <br /> APPLICABLE APPUANCE (Comm) N/0 <br /> NO LESS THAN <br /> Q� o� ENTIRE LENS SHALL 90"A.F.F. <br /> 00 10'MAX. CEILING HEIGHT FIRE ALARM RELAY <br /> ❑P ❑P rE BE NO LESS THAN AND NO LESS <br /> oCONTACT)' B o SHEET2MEfAL SCREWS SIEMENS <br /> o Q (DERATING COVERAGE SHALL 80" AND NO GREATER THAN 6"BELOW (N.C. 1/z"KNOCKOUT SELF TAPPING <br /> APPLY TO CEILING HEIGHTS FT. MOUNTING <br /> \q� MANUAL MPULLL GREATER THAN 10' THAN 96' A.F.F. FINISHED CEILING <br /> FROM OPERABLE ALL VISUAL APPLIANCE LOCATIONS MUST MEET POWER — (__—__WHT/BLU— — — ° 6"x 16 GAUGE BACKING <br /> 42"MIN TO 48"MAX NOTE: — WHT/BLK OR TRACK NOTCHED AROUND <br /> r—__- -__—__�' TO CONTROLLED DEVICE STUDS(TYPICAL),EXTEND <br /> \ PART TO FINISHED NFPA 72 CODE REQUIREMENTS.ANY CIRCUIT 1---- — ----------------------I (NO/NC CONTACTS AS ACROSS 3 STUD BAYS SIEMENS INDUSTRY,INC. <br /> FLOOR NON-COMPLIANT <br /> FORLOCATIONS <br /> MUST BE CODE COMPLIANCE. WHT/YEL APPLICABLE) MINIMUM 15900 SE EASTGATE WAY <br /> REEVALUATED BELLEVUE,WA 98008 <br /> \ FINISHED FLOOR FINISHED FLOOR 425.507.4300 <br /> -VERIFY CONTACT RATINGS OF ASSOCIATED RELAY FOR PROPER CONTROL OF CIRCUIT (T) , PI EACH 800.952.6348 24-HR SERVICE <br /> *ERIBUlC <br /> L DESCRIPTION MOUNTING CONFIGURATION(SEE SYMBOLS LEGEND FOR REDS) A STUD,TYPICAL ( ) <br /> �OR ADDITIONAL INFORMATION REFERENCE NFPA&OTHER APPLICABLE REQUIREMENTS.ACTUAL SYMBOLS INDICATED MAY VARY OR ADDITIONAL INFORMATION REFERENCE NFPA&OTHER APPLICABLE REQUIREMENTS.ACTUAL SYMBOLS INDICATED MAY VARY MULTI-VOLTAGE PILOT RELAY 1/2"ELECTRICAL BOX KNOCKOUT LICENSE:CC #SIEME11919PP <br /> #12 SELF TAPPING[ TYPICAL WIRE TERMINAL CONNECTION DETAIL c/L'�� FIRE ALARM SYSTEM PANELS ELEVATION DETAILS ELEVATOR INTERFACE WIRING DIAGRAM SHEET METAL SCREWS <br /> 05 NOT TO SCALE--SEE APPLICABLE EQUIPMENT INSTRUCTIONS FOR ADDITIONAL INFORMATION 06 NOT TO SCALE--SEE APPLICABLE EQUIPMENT INSTRUCTIONS FOR ADDITIONAL INFORMATION NOT TO SCALE--SEE APPLICABLE DEVICE INSTRUCTIONS FOR ADDITIONAL INFORMATION <br /> This drawing and the information and design application <br /> her contained is the property of SIEMENS INDUSTRY, <br /> PAD LEGEND INC. and is loaned upon the express condition that the <br /> FACU <br /> same be returned to SIEMENS INDUSTRY, INC. upon <br /> request; all information herein contained shall be treated <br /> ® = POSITIVE ° as secret and confidential; no reproduction of this <br /> B <br /> drawing or part thereof shall be made without the written <br /> 0 = NEGATIVE a _ consent of SIEMENS INDUSTRY, Incorporated. <br /> ANN ♦�------------- _ � <br /> SHIELD 1HU) ♦♦ 1 <br /> NEVER LOOP WIRE UNDER U (FT2015) FIRE ALARM RELAY 1 <br /> TERMINALS. BREAK THE WIRE < (NO/NC CONTACTS AS APPLICABLE) }PRIMARY RECALL CONTACTS <br /> RUN TO PROVIDE SUPERVISION o A ♦♦ 4#12 SELF TAPPING 1 <br /> OF CONNECTION. (2HU) FIRE ALARM RELAY ♦♦ SHEET METAL SCREWS 1 <br /> (NO/NC CONTACTS AS APPLICABLE) }ALTERNATE RECALL CONTACTS 1 <br /> ♦ B 1 <br /> #1 2 FIRE ALARM RELAY FIREMAN'S HAT CONTACTS FOR ELEVATOR CABS ♦♦ NAL J <br /> # (NO/NC CONTACTS AS APPLICABLE) () r ♦^ <br /> 6'-0" <br /> 5'-0" 1 ♦♦♦♦ HAVE(3)ROWS OFMOUNTING SECTION <br /> FIRE ALARM RELAY BATTERY SHUNT TRIP CONTACTS <br /> TB-1 (NO/NC CONTACTS AS APPLICABLE,WHERE PROVIDED) (WHERE APPLICABLE) 1 0 ♦♦ HOLES FOR SECURING <br /> 1 0 <br /> _ _ e <br /> + + SHIELD m 1 ♦♦♦ <br /> N((.I� o <br /> I' FIRE ALARM SPEAKER CIRCUIT FROM FACU r ELEVATOR CAB SPEAKER 1 0 <br /> / (WHERE PROVIDED)L i(WHERE APPLICABLE) 1 <br /> IN ♦ --- OUT ♦ 1►♦♦ 4"x 16 GAUGE MIN. <br /> PARTIAL STUDS AT 16"O.C. <br /> SHIELD NOTE:IF SHIELDED WIRE IS USED,NEVER LAND THE SHIELD ON THE DEVICE.FOLD AND ELEVATOR CONTROLLER o \���DO <br /> TAPE THE SHIELD SO IT FORMS A CONTINUOUS CIRCUIT. LAND THE SHIELD ONLY AT THE PANEL (PANEL BY OTHERS) OT150-54 WITH <br /> 3 8 0 KB3 WITH 3" <br /> WHERE THE CIRCUIT ORIGINATED. #10 SMS,TYPICAL EMBED @ 32"O.C. <br /> FINISHED FLOOR 6"MAX.@ END <br /> ELEVATOR SHUNT TRIP & SHUNT CONTROL CIRCUIT MONITORING WIRING DIAGRAM .1 CONDUIT INSTALLATION SUPPORT METHODS ELEVATOR LOBBY/HOISTWAY INFORMATION <br /> 08 NOT TO SCALE--SEE APPUCABLE DEVICE INSTRUCTIONS FOR ADDITIONAL INFORMATION I 0 NOT TO SCALE--SEE APPLICABLE EQUIPMENT INSTRUCTIONS FOR ADDITIONAL INFORMATION 1 1 <br /> TOP OF SHAFT <br /> DETECTORS (WHERE <br /> SHUNT CONTROL CIRCUIT APPLICABLE <br /> REFERENCE ALL APPLICABLE CODES FOR PROPER <br /> _ o ©� <br /> INSTALLATION REQUIREMENTS. <br /> RELAY MODULE 1( MAX. <br /> (BY OTHERS) 12 GA.SLACK 3/8•THREADED STIER ID FIRE SAFETY CONTROL DEVICE SHALL BE LOCATED A DISTANCE <br /> SUSPENSION WIRE STIFFY STRAIGHT ROD, MAXIMUM DISTANCE OF 3 FEET FROM THE CONTROL <br /> 3/8"THREADED FT <br /> FIRE ALARM INPUT ------ —� OR EQUIVALENT POINT OR EQUIPMENT. <br /> C STIF ,ALL UIVA AD, <br /> MODULE, INPUT Eon' I OR EQUIVALENT 02 UTILIZE NORMALLY CLOSED CONTACTS FOR <br /> CONTACT -- -------- SELF-MONITORING INTEGRITY.IF ALTERNATE CONTACTS O/O <br /> ELEVATOR CADDY CLIP K12/ STIFFY GRIPPER ( <br /> POWER OR EQUIVALENT OR EQUIVALENT / ARE REQUIRED,RECONFIGURE CONTROL WIRING <br /> CIRCUIT CONDUIT ACCORDINGLY. <br /> i HANGER <br /> (:!)ELEVATOR INTERFACE POINTS SHALL BE PROVIDED& <br /> TERMINATED BY ELEVATOR CONTRACTOR. <br /> FIRE ALARM RELAY J ®ELEVATOR HOISTWAY AND MACHINE ROOM HEAT ABOVE-GROUND <br /> FOR SHUNT TRIP DETECTORS SHALL ACTIVATE ELEVATOR POWER SHUNT LEVEL <br /> NO CONTACT TRIP.THE MAXIMUM DISTANCE BETWEEN EACH <br /> / SPRINKLER HEAD AND HEAT DETECTOR SHALL NOT <br /> EMT OR Mc CABLE EMT OR Mc CABLE EXCEED 2 FEET.(WHERE SPRINKLERS ARE PROVIDED) <br /> EMT OR MC CABLE (5 DETECTORS IN THE ELEVATOR LOBBY LOCATED WITHIN <br /> SHUNT TRIP CONDUIT OR MC CABLE SUPPORTED BY SUSPENSION CONDUIT OR MC CABLE SUPPORTED BY SUSPENSION ROD CONDUIT OR MC CABLE SUPPORTED BY THREADED 21 FEET OF THE CENTERLINE OF THE ELEVATOR DOOR <br /> BREAKER (I(I(I WIRE ANCHORED TO CEILING GRID SUSPENSION ROD SHALL ACTIVATE THE APPROPRIATE RECALL FUNCTION. <br /> i DESIGNATED RECALL LEVEL LOBBY SMOKE DETECTOR <br /> w SHALL ACTIVATE /O ALTERNATE RECALL;ALL OTHER 0 4 ( <br /> I I I LEVELS SHALL ACTIVATE PRIMARY RECALL FUNCTION. <br /> TOE ELEVATOR (a)DETECTORS LOCATED IN THE ELEVATOR HOISTWAY OR <br /> MACHINERY SPACE SHALL SEND A SEPARATE SIGNAL <br /> 'REFER TO INPUT MODULE INSTALLATION INSTRUCTION FOR END OF LINE RESISTOR VALUE TO THE ELEVATOR CONTROLLER UPON ACTIVATION FOR <br /> THE FIRE HAT LIGHT(ELEVATOR WARNING SIGNAL). <br /> c SPRINKLER SYSTEM MONITORING WIRING DIAGRAM (I)SMOKE DETECTORS INSTALLED IN THE ELEVATOR GROUND LEVEL <br /> 09 NOT TO SCALE--SEE APPLICABLE DEVICE INSTRUCTIONS FOR ADDITIONAL INFORMATION MACHINE ROOM LOCATED ON THE DESIGNATED RECALL AGENCY REFERENCE: <br /> LEVEL SHALL ACTIVATE ALTERNATE ELEVATOR RECALL <br /> 24VDC CIRCUIT I FUNCTION.ELEVATOR MACHINE ROOM SMOKE <br /> DETECTORS ON ALL OTHER LEVELS WILL ACTIVATE <br /> .n PRIMARY ELEVATOR RECALL FUNCTION. <br /> vl FIRE ALARM INPUT w I ®UL LISTED ACCESS PANEL AND ALL OTHER SPECIAL <br /> MODULE** ,eoc I I CONDUIT GYP BOARD PROVISIONS FOR DEVICE MOUNTING IN THE HOISTWAY ID <br /> O/O 0 <br /> (INPUT CONTACT[ I UNISTRUT \ TO BE PROVIDED DED BY GENERAL CONTRACTOR. <br /> J I \ TENS SCREW TIERS SCREW\ <br /> 12-14 x 2-1/2' 12-14 x 2-1 2" FIELD VERIFY ALL POWER CONDITIONS WHICH <br /> \ - / \ - ® MAY EXCEED ANY DEVICE RATINGS THAT <br /> MAY INHIBIT PROPER OPERATION. <br /> O METAL STUD °' • METAL STUD a. 00 OB/08/23 ISSUED FOR PERMIT APK <br /> SUB-GRADE LEVEL REV <br /> WATER FLOW SWITCH I I NO DATE REMARKS INTL <br /> POWER-STRUT P5 CLAMP 1 1000 EATON B-LINE B2301/ EATON B-LINE B2301 / ELEVATOR MACHINE ROOM/ DRAWN: /APK <br /> CONDUIT SERIES ONE-HOLE EMT CONDUIT SERIES ONE-HOLE EMT CONDUIT <br /> EMT STRAP OR EMT STRAP OR CONTROLLER SPACE CHECKED: GN <br /> EQUIVALENT EQUIVALENT EQUIVALENT <br /> FIRE ALARM INPUT To MAX. SHEET DESCRIPTION: <br /> xexr I CONDUIT SUPPORTED BY UNISTRUT AND CONDUIT CLAMP CONDUIT SUPPORTED BY ONE-HOLE STRAP TO STEEL CONDUIT SUPPORTED BY ONE-HOLE STRAP TO STEEL O O DISTANCE FIRE ALARM SYSTEM <br /> MODULE** oo e <br /> o (INPUT CONTACT) Eoi STUD STUD WITH GYP.BOARD _ <br /> 1 O O 2'FT DEVICE MOUNTING 8 WIRING <br /> DETAILS-2 <br /> SPRINKLER I E ❑ELEVATOR ANY HEAD <br /> TAMPER SWITCH ALARM BELL I L INTERFACE EXC24'EEDIN <br /> ` (OR OTHER SPRINKLER I (BY OTHERS) BOTTOM OF SHAFT HEAT <br /> SUPERVISORY SWITCH E MODULE(S) PIT BOTTOM JOB NUMBER: <br /> L _ _ I V (WHERE APPLICABLE 440P-360662 <br /> OPTIONAL,WHERE APPLICABLE <br /> 'REFER TO INPUT MODULE INSTALLATION INSTRUCTION FOR END OF LINE RESISTOR VALUE <br /> **WHEN USING DUAL MONITOR MODULE FOR BOTH,CONNECT WATERFLOW SWITCH TO INPUT#1,AND SUPERVISORY SWITCH TO INPUT#2 <br /> PROJECT NAME\ADDRESS: <br /> SECURE SELF STORAGE-EVERETT EXPANSION <br /> BROADWAY EVERETT SELF STORAGE <br /> 8407 BROADWAY <br /> EVERETT,WA 98208 <br /> DRAWING <br /> 2 DEVICE MOUNTING WIRING DETAILS-2 <br /> NUMBER: FA5 O2 <br /> NOT TO SCALE <br /> SHEET SIZE:ARCH EI-30xA2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.