Laserfiche WebLink
SIEMENS <br /> Desigo@ Fire Safety <br /> System PeripheryC • . • <br /> Models • • • <br /> •-FJORI Product Overview <br /> ❑ Used with Desigo panels The periphery boards (Models FC12016-U1 and FC12017-1.11) are the <br /> • Model FC12O16-U1 is used with Model main components for operation of the Desigo panels (Models FC2025 <br /> FC2O25 panel and FC2050). Both models are FM (#3010); CSFM (#7165-0067:0259) <br /> • Model FC12O17-U1 is used with Model and FDNY(#6104)Approved. <br /> F2O5O panel Each module operates and monitors input-device identity; as well as <br /> ❑ Maximum 252 point device addresses per controls the signaling-line circuits that communicate with smoke <br /> integrated loop card detectors and other field devices (i.e., — FDNet). All functions are <br /> • Up to 252 addresses are used with supported by the power supplies of either Model FP201 1-1.11 or Model <br /> Model FC12O16-U1 FP2012-U1. <br /> • Up to 504 addresses are used with Model FP2011-U1 provides regulated 24VDC, nominal, 6 amps (max), <br /> Model FC12O17-U1 while Model FP2012-U1 offers regulated 24VDC, nominal, 11.5 Amps <br /> • Model FC12O17-Ul has two(2) (max)to the Models FC2025 and FC2050 Desigo Fire Safety systems. <br /> integrated loop cards(Loop A /Loop B) <br /> with EMC surge protection for eight(8) Specifications <br /> Style 4,or four(4)Style 6/7 loops <br /> • Model FC12O16-U1 has one(1) Each periphery board is equipped with two (2) programmable'Class B' <br /> integrated loop card(Loop A /Loop B) (Style Y) or'one (1) Class A' (Style Z) NAC, providing 24VDC, nominal <br /> with EMC surge protection for four(4) @ up to 3A per circuit of audible/visual notification appliances. <br /> Style 4,or two(2)Style 6/7 loops Models FC12016-U 11 FC12017-U 1 have integrated FDNet loop circuit <br /> ❑ NAC connection for one(1)Class A or two with built-in EMI surge protection, which allows automatic devices to <br /> (2)'Class B'functions be installed and configured for'Class B'or'Class A'circuit operation. <br /> • 3 Amps max.for NAC for <br /> synchronization and alarms Model FC12016-U1 supports (1) one-to-four (4) 'Class B' circuits — or <br /> ❑ Two(2)plugs for optional extensions supports (1) one-to-two (2) 'Class A' circuits that can supervise and <br /> • Leased line/city-tie module control up to 252 devices. Model FC12017-U1 supports (1) one-to- <br /> Notification Appliance Circuit(NAC) eight (8) 'Class B' circuits — or supports (1) one-to-four (4) 'Class A' <br /> Expansion Module or Releasing Module circuits that can supervise and control up to 504 devices. <br /> ❑ Additional peripheral-data bus connection The following devices work with the FDNet loop: <br /> for LED or digital alarm communication ■ Model W-series devices <br /> transmitter (DACT)modules ■ Model'S'-series devices <br /> ❑ Field-wiring configuration via removable • Model'C'-series devices <br /> terminal blocks ■ Monitor module <br /> ❑ Degrade-mode functions `• <br /> ❑ Four(4)configurable relay outputs <br /> ❑ Battery charger included <br /> ❑ Auxiliary output <br /> • (24VDC,nominal;1.5 Amps) <br /> k <br /> ❑ UL 864101h Edition Listed, ULC Listed <br /> ❑ FM,CSFM and NYC Fire Dept.Approved ' . <br /> APPROVED � <br /> Siemens Data Sheet 6802 <br /> Smart Infrastructure—Building Products usa.siemens.com/fire <br />