Laserfiche WebLink
SIEMENS <br /> ProductOverview <br /> Model FCA2018-U1: The Remote Peripheral Module (Model FCA2018-U1) provides a means of connecting <br /> ❑ Provides connection to the external-event a Desigo Fire Safety system to a parallel printer for creating a hard copy of system- <br /> printer(Model PAL-1) status and configuration reports. This supervised, intelligent module contains built- <br /> Provides an interface to remote printers: in transient protection and plain-decimal addressing. <br /> Two(2)serial ports and one(1)parallel <br /> ❑ Mounts remotely from the Desigo Fire Specifications <br /> Safety System Model FCA2018-U1 is remotely connected to the Model FCA2016-U1 RS-485 <br /> ❑ Provided in its own enclosure communication bus from any Desigo Fire Safety system enclosure. Model FCA2018- <br /> ❑ Supervised intelligent module U1 uses 'Class B' (Style 4) or'Class A' (Style 6) wiring, and provides two (2) RS-232 <br /> ❑ Supports'Class B'(Style 4)or'Class A' (serial) ports and a single parallel port that allow connection to the parallel printer <br /> (Style 6)wiring (Model PAL-1). <br /> ❑ Fast installation with IN/OUT screw When Model PAL-1 is used with a Model FCA2018-U1 remote peripheral module, <br /> terminals using#12 to#18 AWG wire Model FCA2018-U1 supervises the PAL-1 printer for ON,OFF Line I POWER ON I PAPER <br /> ❑ Built-in transient protection OUT I PAPER JAM, and wiring-fault conditions, as required by UL for NFPA72 <br /> ❑ Downloadable module firmware proprietary systems. Event 1 report printing, is generated at the operating unit <br /> Built-in flash electrically erasable (Model FCM20-series)on the main Desigo system. <br /> programmable read-only memory Note: For PAL-1 connectivity with Remote Peripheral Modules on Desigo Fire Safety 252- <br /> (EEPROM) point and 504-point addressable systems, a Model FCA2016-U1 (RS-485) interface must <br /> ❑ Plain-decimal addressing be ordered,used. <br /> ❑ UL 864 10th Edition Listed, ULC Listed Model FCA2016-U1 is not required for connection of a Model PAL-1 parallel printer with a <br /> ❑ FM,CSFM&NYC Fire Dept.Approved Desigo (Model FC2005) addressable panel because Desigo 50-point addressable FACPs <br /> each have a built-in RS-485 interface. <br /> Model FCA2016-U1: <br /> Model FCA2018 U1 has necessary mounting <br /> Dual,standardized RS 485 interface that is❑ i s <br /> used on 252 ze point control panels flanges to allow the module to be mounted <br /> unobtrusively under a table or behind a desk. <br /> ❑ RS-485 module provides communication to <br /> Model FCA2018-U1 for managing and Model FCA2018 U1 runs on required 24VDC, <br /> supervising Model PAL-1 nominal, power and this source for power can be <br /> El Supports'Class B'(Style 4)and 'Class A' provided from the auxiliary power connection on <br /> (Style 6)wiring configurations the Desigo system enclosure. <br /> ❑ Up to eight(8)devices on the RS-485 Power from other UL Listed 24VDC power sources <br /> Universal Fire Protocol(UFP)network is also acceptable. Model FCA2018-U1 has screw <br /> ❑ Electrical isolation between the RS-485 terminals capable of supporting a 12 to 18 <br /> interface and the Desigo Fire Safety System American Wire Gauge(AWG)configuration. .. - <br /> ❑ Ground-fault monitoring The 252-point addressable system (Model FC2025) Remote Peripheral Module <br /> ❑ UL8641oth Edition Listed, ULC Listed and the 504-point addressable system (Model <br /> FC2050) require having a RS-485 interface (Model <br /> ❑ FM,CSFM&NYC Fire Dept.Approved FCA2016-1_11) to provide communication to the t,�'� <br /> Remote Peripheral Module. <br /> Models FCA2018-U1 and FCA2016-U1 are FM <br /> (#3010); CSFM (#7165-0067:0259) and FDNY <br /> (#6104)Approved. <br /> RS-485 Interface <br /> AVVROVED <br /> Siemens Datasheet 6811 <br /> Smart Infrastructure- Building Products <br /> usa.siemens.comlfire <br />