My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8407 BROADWAY 2024-11-12
>
Address Records
>
BROADWAY
>
8407
>
8407 BROADWAY 2024-11-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2024 11:24:19 AM
Creation date
10/29/2024 9:59:58 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
8407
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
259
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Field-Device Programmer/ <br /> Model FDT421 is compatible with the Siemens field-device programmer I test unit (Model DPU), which is a compact, <br /> portable and menu-driven accessory for electronically programming and testing these addressable detectors promptly and <br /> reliably. For instance,the field technician selects the accessory's program mode,and enters the desired address. <br /> Mode[ DPU eliminates the need for cumbersome, unreliable mechanical programming methods (e.g. — dials and rotary <br /> switches), and reduces installation and service costs by electronically programming and testing the detector prior to <br /> installation. When set in 'test' mode, Mode[ DPU will perform a series of diagnostic tests without altering the address or <br /> other stored data,allowing technicians to determine if the detector is operating properly. <br /> Each field-device programmer / test unit operates on AC power or rechargeable batteries, providing flexibility and <br /> convenience in the programming/testing of fire-safety equipment from practically any location. Additionally,with the use <br /> of a Mode[ DPU unit, there is no longer a cause for concern with any vibration, corrosion and other deteriorating conditions <br /> that can accompany the vitality of a mechanical-addressing mechanism. <br /> The encompassing result is an intelligent detector that provides enhanced detection capability to a wide range of products <br /> of combustion — while offering unsurpassed rejection to nuisance-alarm sources, including: dust I steam I aerosols and <br /> other deceptive phenomena that could cause false alarms. <br /> Technical Data Panel Compatibilities Details for Orderinq <br /> +32°-+120°F(0°-+49°C) OR MODEL DATA PANEL OR MODEL PART PRODUCT <br /> [with 145°F(63°C)1 1557(68°C) TYPE SHEET TYPE NUMBER <br /> OPERATING 11657(74°C)and 175°F(79°C) <br /> TEMPERATURE: alarm-threshold settings] FDT421 S54320-F5-A1 Thermal(Heat)Detector <br /> +32°-+100°F,(0°-+38°C) XLS 6300 FireFinder(fire) <br /> [With 135°F(57°C)alarm <br /> threshold setting] Compatible Devices <br /> Model FDT421 provides XLSV 6340 FireFinder(fire w/voice) MODEL <br /> seven(7)field-selectable, OR PART PRODUCT <br /> pre-programmed TYPE 11 <br /> NUMBER <br /> temperature settings: Sounder base with Loop- <br /> Fixed 135°F(57°C) Desigo ABHW 46 S54320 F13A1 <br /> Modular 7300 Desigo Modular(overview) Power Option <br /> Fixed 145°F(63°C) Sounder base for <br /> •Fixed 155°F(68°C) ABHW-4S S54320-F14A1 Sleeping Areas <br /> THERMAL •Fixed 165°F(74°C) <br /> RATING: •Fixed 175°F(79°C) ADB-BOX 500-698360Surface Mount Adapter Box <br /> •Rate-of-Rise: FC2005 6813 Desigo Fire Safety for Audible Base <br /> 15°F I min.(8.3°C) 50-point addressable Relay base compatible with <br /> at fixed 135°F(57°C) DB2-HR S54370-F12-A1 Siemens standard and <br /> •Rate-of-Rise: advanced detectors <br /> 15°F/min.(8.3°C) DB-11 500 094151 Detector <br /> at fixed 175°F(79°C) FC2025 Desigo Fire Safety 252-pt. Mounting Base <br /> addressable(fire) <br /> RELATIVE 0-95% DB-11E 500-094151E Detector Base,small <br /> HUMIDITY: (non-condensing) <br /> AIR Remote Alarm Indicator: <br /> PRESSURE: No effect Desigo Fire Safety 504-pt. RL-HC 500-033230 4"(10.2 cm)octagon-box <br /> FC2050 mount,red <br /> addressable(fire) <br /> INPUT VOLTAGE 16VDC-30VDC RL-HW 500-033310 Remote Alarm Indicator: <br /> RANGE: IJ single-gang box mount,red <br /> 'ALARM' Desigo Fire Safety LK-11 500 695350 Base Locking Kit <br /> CURRENT,MAX: 410pA 252-point addressable <br /> FV2025 (fire w/Intelligent Voice <br /> STANDBY' Communication[IVC]) See: www.STI-USA.com for further <br /> CURRENT,MAX: 250pA 6829 details on ordering Model STI-9604 <br /> 504-pt.addressable In Canada order: <br /> 50-ft.(15.24 m.)centers FV2050 fire w/Intelligent Voice <br /> MAXIMUM ( g MODEL <br /> SPACING: (2500 sq.ft.1232.3 sq.m.), Communication[IVC]) OR PART PRODUCT <br /> per NFPA 72 and ULC-S524 TYPE NUMBER <br /> DETECTOR 0317 Lbs Detector Mounting <br /> WEIGHT: . .(0.144 kg.) DB-11C 500-095687 Base, ULC Listed <br /> Siemens <br /> Smart Infrastructure- Building Products —4— usa.siemens.com/fire <br />
The URL can be used to link to this page
Your browser does not support the video tag.