My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3020 RUCKER AVE SNO CO HEALTH DISTRICT 2024-11-12
>
Address Records
>
RUCKER AVE
>
3020
>
SNO CO HEALTH DISTRICT
>
3020 RUCKER AVE SNO CO HEALTH DISTRICT 2024-11-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2024 8:09:00 AM
Creation date
10/29/2024 10:52:49 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3020
Tenant Name
SNO CO HEALTH DISTRICT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: FA2401-002 ? <br /> Site Address: 3020 Rucker Ave <br /> SNOHOM SH COUNTY HEALTH DEPARTMENT Applicant Fire Protection Inc <br /> Application Date:01/0 512 0 24 FIRE PROTECTION INC. <br /> Description: Installation of a UL Listed Wireless 17410 Ash Way,Ste 8 <br /> Fire Alarm Communicator Lynnwood,WA 98037 <br /> Review Date: 01/08/2024 425-290-9600 <br /> FPISEATTLE.COM <br /> TELGUARD D STOEEOT OH <br /> EVERETT <br /> Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown <br /> 01/08/2024 12:13:42 <br /> EVERETT AA PM NFPA® <br /> 9 000805173 <br /> ROY L CATS <br /> OPERATIONAL MATRIX TYPICAL WIRING AND INSTALLATION DETAILS SHEET INDEX QV60TECTj Q`� oy <br /> SHEET # SHEET DESCRIPTION „ <br /> W n <br /> FA 0.0 FIRE ALARM AES INSTALLATION �'y NFPA <br /> SYSTEM OUTPUTS PROJECT DETAILS �� Y� <br /> Required Fire Safe Control CFPS <br /> Central Supervising Station m #1473 <br /> Control Unit Annunciation ° Co 1. THE EXISTING 4-STORY BUILDING IS FULLY-SPRINKLED AND HAS AN EXISTING ADDRESSABLE FIRE ALARM <br /> o� �m CONTROL PANEL (SILENT KNIGHT 5808) LOCATED IN THE BUILDINGS RISER ROOM. <br /> c co Oc Oc m c �o O O O O O CoP,P. , 2. A NEW UL LISTED WIRELESS CELLULAR COMMUNICATOR (TELGUARD HW-TG7LAF02) IS BEING INSTALLED, c' <br /> o ap SIGNALS WILL BE TRANSMITTED BY ZONES TO THE UL LISTED SUPERVISING STATION. <br /> a n <br /> m C�mr c°j C�O AF o 3. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. ui Z LL <br /> yr 2 y�Q m Q om � 0 H Z twi rc <br /> q�J of°�c®aQ my�2�Q OO OOO CONTACT INFO w a <br /> ° C ti Q 51 m <br /> e 10 ti m <br /> Owe 1 ❑ a r <br /> % F q r° cm S�m°Qom St_Eos ta1is 3 o PROPERTY OWNER FIRE ALARM CONTRACTOR Q E 5❑ SNOHOMISH COUNTY FIRE PROTECTION INC O m <br /> g O <br /> ❑ 3020 RUCKER AVE 17410 ASH WAY, Ste 8 Y G w n C <br /> EVERETT, WA 98201 LYNNWOOD, WA 98037 L) <br /> a a a o a • zawrc" <br /> a $ a o �° m F ® D F°wer Leo ❑ CONTACT : JIM NEAL CONTACT DAVID MOW m rc in O <br /> LED M°Je PHONE:: 425.760.4766 PHONE 425.290.9600 m w w f~ o <br /> ° m ° F F F F Toggle s°��°"� EMAIL JIM.NEAL®CO.SNOHOMISH.WA.US EMAIL DAVID@FPISEATTLE.COM z Pi J p w f <br /> �m�m�m Qm Qm Qm Qm �m �m o 0 Sim 3>a#o <br /> TELGUARD o rc H a o <br /> SYSTEM INPUTS A BI C D E F G H I } TG-7FS CODE INFORMATION REVISION RECORD <br /> 1 Manual Fire Alarm Pull-Station X X X X 1 TELCO <br /> � DATE DESCRIPTION <br /> 2 Smoke Detectors X X X X 2 o Battery AUTHORITY HAVING JURISDICTION CITY OF EVERETT <br /> K Q Connector <br /> Q 3 Wet Waterflow X X X X X 3 M SN�2 FIRE CODE INTERNATIONAL FIRE CODE, 2018 EDITION <br /> 4 Heat Detectors X X X X 4 STC1 BUILDING USE AND OCCUPANCY : B - SPRINKLED <br /> 5 Tampers X X 5 FF <br /> (NO-) , STANDARDS: 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT STANDARDS <br /> rn 6 Low Alr X X 6 El. m CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> 7 Fire Alarm AC Power Failure X X 7 REMOTE SUPERVISING STATION SECURITAS <br /> OJO 8 Fire Alarm System Low Battery X X 8 EARTH PRIME FIRE ALARM CONTRACTOR FIRE PROTECTION, INC. <br /> � 9 Open Circuit X X 9 GROUND <br /> PAWHZP rminc Battery TO AC PARCEL NUMBERS 00437572002200 <br /> 10 Ground Fault X X 10 TELGUARDTG7FS _ <br /> A B C D E F G H I PRRAWYSLIBSCRMERLMr (12V 800MAR <br /> INSTALLATION NOTES <br /> 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> VICINITY MAP TYPICALFACP TOTG7FS VvMM IAGRAM 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS-BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> SHB'4rI'J=5808FIREALARMCONMOLPANQ, PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> SITE PLAN AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). <br /> 1 5. THE SYSTEM WILL BE 100% PRE-TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND <br /> Priest Point PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL <br /> INSPECTION. DATE: 01/04/2023 <br /> 6. THE TELGUARD REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE FACP SHALL PROJECT NAME <br /> DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING DEDICATED POWER <br /> N L _ TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT SERVES THE FIRE <br /> m ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT H <br /> WALL ST - d 529 (NFPA72, SECTION 10.5.5.2). LU <br /> ° AkChimney Sweep'& — -- o <br /> o Dryer Vent Cleaning x <br /> r� OUTDOOR DEVICE INSTALLATION REQUIREMENTS J r <br /> Q 9 STROBE&BELL LL, O <br /> #Sn_o/), mish County FACP IN W Q rn <br /> Health Department SPRINKLER ROOM FIRE ALARM DEVICE INSTALLATION REQUIREMENTS x <br /> I� \ NOT PERMITTED r LLI <br /> Bunk Fos u, 3RAC°ET DIFFUSER HERE 4" Z U <br /> �_� ¢ ¢ J Q J-BOX GRID II 0 I� <br /> ...111LLL LU <br /> Fobes Hill \ Q �p�Jp� U CD <br /> a FA DEVICE DCEIDNC ETECTOR , SMOKE x N W 0 <br /> 9 MINIMUM 3' 4 M , <br /> ® AWAY FROM NOT PERMITTED ��. W <br /> HVAC DIFFUSERS HERE 0 <br /> 526 H S SMOKE x <br /> 0 <br /> CASCADE VIEW Snohomish N <br /> 99 <br /> MAX HEIGHT 02^AF.F a MIN HEIGHT 82" SHEET TITLE <br /> I AEF Grp � <br /> Eastmont l o <br /> FAA <br /> Paine ® N FIRE ALARM <br /> (Field=Lake 96 PACIFIC AVE A -- O z <br /> �Stti6kney 96 II . PROJECT DETAILS <br /> 66" AF.F 60" AF_F PII <br /> 0 SHEET NUMBER <br /> Not to Scale <br /> FA 0.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.