Permit#: FA2401-002 ? <br /> Site Address: 3020 Rucker Ave <br /> SNOHOM SH COUNTY HEALTH DEPARTMENT Applicant Fire Protection Inc <br /> Application Date:01/0 512 0 24 FIRE PROTECTION INC. <br /> Description: Installation of a UL Listed Wireless 17410 Ash Way,Ste 8 <br /> Fire Alarm Communicator Lynnwood,WA 98037 <br /> Review Date: 01/08/2024 425-290-9600 <br /> FPISEATTLE.COM <br /> TELGUARD D STOEEOT OH <br /> EVERETT <br /> Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown <br /> 01/08/2024 12:13:42 <br /> EVERETT AA PM NFPA® <br /> 9 000805173 <br /> ROY L CATS <br /> OPERATIONAL MATRIX TYPICAL WIRING AND INSTALLATION DETAILS SHEET INDEX QV60TECTj Q`� oy <br /> SHEET # SHEET DESCRIPTION „ <br /> W n <br /> FA 0.0 FIRE ALARM AES INSTALLATION �'y NFPA <br /> SYSTEM OUTPUTS PROJECT DETAILS �� Y� <br /> Required Fire Safe Control CFPS <br /> Central Supervising Station m #1473 <br /> Control Unit Annunciation ° Co 1. THE EXISTING 4-STORY BUILDING IS FULLY-SPRINKLED AND HAS AN EXISTING ADDRESSABLE FIRE ALARM <br /> o� �m CONTROL PANEL (SILENT KNIGHT 5808) LOCATED IN THE BUILDINGS RISER ROOM. <br /> c co Oc Oc m c �o O O O O O CoP,P. , 2. A NEW UL LISTED WIRELESS CELLULAR COMMUNICATOR (TELGUARD HW-TG7LAF02) IS BEING INSTALLED, c' <br /> o ap SIGNALS WILL BE TRANSMITTED BY ZONES TO THE UL LISTED SUPERVISING STATION. <br /> a n <br /> m C�mr c°j C�O AF o 3. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. ui Z LL <br /> yr 2 y�Q m Q om � 0 H Z twi rc <br /> q�J of°�c®aQ my�2�Q OO OOO CONTACT INFO w a <br /> ° C ti Q 51 m <br /> e 10 ti m <br /> Owe 1 ❑ a r <br /> % F q r° cm S�m°Qom St_Eos ta1is 3 o PROPERTY OWNER FIRE ALARM CONTRACTOR Q E 5❑ SNOHOMISH COUNTY FIRE PROTECTION INC O m <br /> g O <br /> ❑ 3020 RUCKER AVE 17410 ASH WAY, Ste 8 Y G w n C <br /> EVERETT, WA 98201 LYNNWOOD, WA 98037 L) <br /> a a a o a • zawrc" <br /> a $ a o �° m F ® D F°wer Leo ❑ CONTACT : JIM NEAL CONTACT DAVID MOW m rc in O <br /> LED M°Je PHONE:: 425.760.4766 PHONE 425.290.9600 m w w f~ o <br /> ° m ° F F F F Toggle s°��°"� EMAIL JIM.NEAL®CO.SNOHOMISH.WA.US EMAIL DAVID@FPISEATTLE.COM z Pi J p w f <br /> �m�m�m Qm Qm Qm Qm �m �m o 0 Sim 3>a#o <br /> TELGUARD o rc H a o <br /> SYSTEM INPUTS A BI C D E F G H I } TG-7FS CODE INFORMATION REVISION RECORD <br /> 1 Manual Fire Alarm Pull-Station X X X X 1 TELCO <br /> � DATE DESCRIPTION <br /> 2 Smoke Detectors X X X X 2 o Battery AUTHORITY HAVING JURISDICTION CITY OF EVERETT <br /> K Q Connector <br /> Q 3 Wet Waterflow X X X X X 3 M SN�2 FIRE CODE INTERNATIONAL FIRE CODE, 2018 EDITION <br /> 4 Heat Detectors X X X X 4 STC1 BUILDING USE AND OCCUPANCY : B - SPRINKLED <br /> 5 Tampers X X 5 FF <br /> (NO-) , STANDARDS: 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT STANDARDS <br /> rn 6 Low Alr X X 6 El. m CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> 7 Fire Alarm AC Power Failure X X 7 REMOTE SUPERVISING STATION SECURITAS <br /> OJO 8 Fire Alarm System Low Battery X X 8 EARTH PRIME FIRE ALARM CONTRACTOR FIRE PROTECTION, INC. <br /> � 9 Open Circuit X X 9 GROUND <br /> PAWHZP rminc Battery TO AC PARCEL NUMBERS 00437572002200 <br /> 10 Ground Fault X X 10 TELGUARDTG7FS _ <br /> A B C D E F G H I PRRAWYSLIBSCRMERLMr (12V 800MAR <br /> INSTALLATION NOTES <br /> 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> VICINITY MAP TYPICALFACP TOTG7FS VvMM IAGRAM 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS-BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> SHB'4rI'J=5808FIREALARMCONMOLPANQ, PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> SITE PLAN AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). <br /> 1 5. THE SYSTEM WILL BE 100% PRE-TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND <br /> Priest Point PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL <br /> INSPECTION. DATE: 01/04/2023 <br /> 6. THE TELGUARD REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE FACP SHALL PROJECT NAME <br /> DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING DEDICATED POWER <br /> N L _ TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT SERVES THE FIRE <br /> m ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT H <br /> WALL ST - d 529 (NFPA72, SECTION 10.5.5.2). LU <br /> ° AkChimney Sweep'& — -- o <br /> o Dryer Vent Cleaning x <br /> r� OUTDOOR DEVICE INSTALLATION REQUIREMENTS J r <br /> Q 9 STROBE&BELL LL, O <br /> #Sn_o/), mish County FACP IN W Q rn <br /> Health Department SPRINKLER ROOM FIRE ALARM DEVICE INSTALLATION REQUIREMENTS x <br /> I� \ NOT PERMITTED r LLI <br /> Bunk Fos u, 3RAC°ET DIFFUSER HERE 4" Z U <br /> �_� ¢ ¢ J Q J-BOX GRID II 0 I� <br /> ...111LLL LU <br /> Fobes Hill \ Q �p�Jp� U CD <br /> a FA DEVICE DCEIDNC ETECTOR , SMOKE x N W 0 <br /> 9 MINIMUM 3' 4 M , <br /> ® AWAY FROM NOT PERMITTED ��. W <br /> HVAC DIFFUSERS HERE 0 <br /> 526 H S SMOKE x <br /> 0 <br /> CASCADE VIEW Snohomish N <br /> 99 <br /> MAX HEIGHT 02^AF.F a MIN HEIGHT 82" SHEET TITLE <br /> I AEF Grp � <br /> Eastmont l o <br /> FAA <br /> Paine ® N FIRE ALARM <br /> (Field=Lake 96 PACIFIC AVE A -- O z <br /> �Stti6kney 96 II . PROJECT DETAILS <br /> 66" AF.F 60" AF_F PII <br /> 0 SHEET NUMBER <br /> Not to Scale <br /> FA 0.0 <br />