Laserfiche WebLink
MICROINVERTERS SPECIFICATION PV MODULE RATING A STC Rooftop conductor ampacities designed in compliance with 120% RULE <br /> MICROINVERTER MAKE AP SYSTEMS MANUFACTURER ZNSHINESOLAR ZXM7-SH108-410M art. 690.8, Tables 310.15(B)(1), 310.15(C)(1), 310.15(B)(2), 0 <br /> MICROINVERTER MODEL NO. DS3-L 310.16, Chapter 9 Table 4, 5, &9. Locations specific BUS BAR RATING X 120%) - MAIN BREAKER RATING infinit solar <br /> MAX.POWER-POINT CURRENT(IMP) 13.10 AMPS p p infinity <br /> solar <br /> AC OUTPUT 768 W temperature obtained from ASHRAE 2017 data tables = MAX. PV OCPD <br /> MAX INPUT VOLTAGE 60 V MAX.POWER POINT VOLTAGE(VMP) 31.30 VOLTS INFINITY HOME SOLUTIONS <br /> MAX AC CURRENT 3.20 A OPEN-CIRCUIT VOLTAGE(VOC) 37.50 VOLTS (225A x 120%) - 200 = 70A 6405 E MILL PLAIN <br /> VANCOUVER WA98661 <br /> PHONE:1-800-818-0598 <br /> MAX OUTPUT VOLTAGE 240 V SHORT-CIRCUIT CURRENT(ISC) 13.84 AMPS RECORD LOW TEMP 5°CINFINITY SOLAR.COM <br /> AMBIENT TEMP(HIGH TEMP 2%) 26°C NOM.MAX.POWER AT STC(PMAX) 410 WATT <br /> MODULE: (19) ZNSHINESOLAR ZXM7-SH108-410M POINT OF INTERCONNECT, LOAD SIDE <br /> REVISIONS <br /> INVERTER: (10)AP SYSTEMS DS3-L MAX.SYSTEM VOLTAGE 1500V CONDUIT HEIGHT 7/8" EXISTING 240V/225A BUS BAR RATING, Description Date Rev <br /> VOC TEMPERATURE COEFFICIENT -0.29%/°C ROOF TOP TEMP 48°C MAIN SERVICE PANEL,SINGLE PHASE, Initial Design 4/24/24 00 <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT CONDUCTOR TEMPERATURE RATE 901C WITH A 200A MAIN BREAKER <br /> WITHIN 10' OF UTILITY METER NOTE: (SOLAR PV SYSTEM EQUIPPED WITH UTILITY COMPANY-SNOHOMISH COUNTY <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED UTILITY METER#64 292 908 <br /> NOTE : WITHIN 3FT OF AC DISCONNECT. THIS PANEL IS FED BY MULTIPLE SOURCES EXISTING <br /> (UTILITY AND SOLAR) Signature with seal <br /> ATTIC RUN -YES BI-DIRECTIONAL <br /> SHUTDOWN - NO AC OUTPUT CURRENT 32A M UTILITY METER, <br /> 1-PHASE,3W, <br /> NOMINAL AC VOLTAGE 240V 120V/240V <br /> w <br /> � Project Name& <br /> LL_ EXISTING 200A Address <br /> (19)ZNSHINESOLAR ZXM7-SH108-410M o FUSE BOX <br /> (10)AP SYSTEMS DS3-L INVERTERS (N) 125A COMBINER PANEL, (N)BLADE TYPE o <br /> BRANCH 1 -09 MODULES WITH 05 MICRO INVERTERS 240V,3W,1-PHASE NON-FUSIBLE AC DISCONNECT Lli <br /> NEMA 3R 60A-2P 120/240VAC U <br /> (VISIBLE, LOCKABLE, LABELED) w > <br /> 200A E--{ CO co <br /> L.LI 6, Q Q <br /> (E)LOADS Q Z Z <br /> 0 w 3: <br /> : w w � z J <br /> (N)JUNCTION BOX 0 0- � O Q <br /> 600 V, NEMA 4 P0A (N)PV BREAKER cn UO LU = w <br /> N UL LISTED 40AI2P = ry w <br /> ------------------�-- Q > <br /> -------- ---------- -------� L1 /ram <br /> BRANCH 2-10 MODULES WITH 05 MICRO INVERTERS 20A 0LO <br /> w <br /> L1 L1 L2 0 0 <br /> I m <br /> L2 L2 LU <br /> I � <br /> L1 L1 G <br /> G <br /> a a a a a a a a a a --- — ---- ---- — G <br /> J L Sheet Name <br /> —1— <br /> 3-LINE <br /> —--------^/--------/---------^/--------^/ <br /> EXISTING GROUNDING DIAGRAM <br /> 1 2 3 3 ELECTRODE SYSTEM Sheet Size <br /> ANSI B <br /> WIRE MAX PARALLEL C.0 PV CURB. TOTAL CONT. CURR WIRE SIZE\TYPE\AMP. WIRE #C.C.C. CONDUIT TEMP CONDUIT WIRE DERATED MAX. CONT. LENGTH VOLTAGE 1 1" X 17„ <br /> TAG# DEVICES RATING MULT CURR X 125% OCP DE-RATE: FILL: AMP: AMPACITY CURRENT GND FT. MAX DROP(/a) <br /> Sheet Number <br /> 05 x 3.20 x N/A = 16.00A 20.00A #10\THWN \40A @90°C 20A 2 TRUNK <br /> AIR CABLE <br /> 1.00 x 1.00 x 40A 40.00A <br /> 16.00A #6 AWG 20 0.28 E 1 .1 <br /> O 05 x 3.20 x N/A = 16.00A 20.00A #10\THWN \40A @90°C 20A 4 3/4" EMT 1.00 x 0.80 x 40A 32.00A 16.00A #8 AWG 35 0.48 0.93< <br /> 2 <br /> O10 x 3.20 x N/A = 32.00A 40.00A #8 \THWN \ 50A @75°C 40A 2 3/4" EMT 1.00 x 1.00 x 50A 50.00A 32.00A #8 AWG 10 0.17 <br />