My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5510 S 3RD AVE 2024-11-08
>
Address Records
>
S 3RD AVE
>
5510
>
5510 S 3RD AVE 2024-11-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2024 11:32:32 AM
Creation date
10/29/2024 11:58:38 AM
Metadata
Fields
Template:
Address Document
Street Name
S 3RD AVE
Street Number
5510
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11� <br /> EZ SOLAR <br /> JB-3 EZf SOLAR Installation Manual BLUE RAVE R <br /> Specification Sheet making solar simple, PV Junction Box for Composition/Asphalt Shingle Roofs <br /> making solar simple, PV Junction Box for Composition/Asphalt Shingle Roofs <br /> A. System Specifications and Ratings <br /> o { <br /> • Maximum Voltage: 1,000 Volts QUICK <br /> AR GUIDE WATCH INSTALLVIDEO <br /> • Maximum Current: 80 Amps <br /> • Allowable Wire: 14 AWG—6 AWG <br /> • Spacing: Please maintain a spacing of at least 1/2" between uninsulated live parts and fittings for <br /> conduit, armored cable, and uninsulated live parts of opposite polarity. <br /> • Enclosure Rating:Type 3R <br /> • Roof Slope Range: 2.5—12:12 = <br /> • Max Side Wall Fitting Size: 1" <br /> • Max Floor Pass-Through Fitting Size: 1" <br /> • Ambient Operating Conditions: (-35°C) - (+75°C) r� <br /> • Compliance: ` <br /> -JB-3: UL1741, CSA C22.2 No. 290 J <br /> -Approved wire connectors: must conform to UL1741 <br /> • System Marking: Interek Symbol and File#5025824 <br /> Y g Y - <br /> • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion <br /> between components, components that are found to be affected are to be replaced immediately. Slide junction box onto the rail at desired <br /> 1.Attach the SS Clamps to the Junction Box. location and secure the box with the SS <br /> Table 1:Typical Wire Size,Torque Loads and Ratings Pro Tip: Compress the SS Clamps against the back wall and rock into place. Clamps. Let the JB-3 lay on the roof with the <br /> 1 Conductor 2 Conductor <br /> Torque hex head rotated to the top. <br /> Type NM Inch Lbs Voltage Current <br /> ABB ZS6 terminal block 10-24 awg 16-24 awg Sol/Str 0.5-0.7 6.2-8.85 600V 30 amp <br /> ABB ZS10 terminal block 6-24 awg 12-20 awg Sol/Str 1.0-1.6 8.85-14.16 600V 40 amp <br /> ABB ZS16 terminal block 4-24 awg 10-20 awg Sol/Str 1.6-2.4 14.6-21.24 600V 60 amp <br /> ABB M6/8 terminal block 8-22 awg Sol/Str .08-1 8.85 600V 50 amp <br /> Ideal 452 Red mre%"".r 8-18 awg Sol/Str Self-Torque Self-Torque 600V I <br /> Ideal 451 Yellow W;GN T 10-18 awg Sol/Str Self-Torque Self-Torque 600V <br /> Ideal,In-Sure 10-14 awg Sol/Str Self-Torque Self-Torque 600V <br /> WAGO,2204-1201 10-20 awg 16-24 awg Sol/Str Self-Torque Self-Torque 600V 30 amp l <br /> WAGO,221-612 10-20 awg 10-24 awg Sol/Str Self-Torque Self-Torque 600V 30 amp f a <br /> Dottie DRC75 6-12 awg Sol/Str Snap-In Snap-In <br /> ESP NG-53 4-6 awg Sol/Str 45 2000V <br /> 10-14 awg Sol/Str 35 <br /> 4-6 awg Sol/Str 45 <br /> ESP NG 717 10-14 awg Sol/Str 35 2000V <br /> Brumall 4-5,3 4-6 awg Sol/Str 45 2000V <br /> 10-14 awg Sol/Str 35 <br /> Table 2:Minimum wire-bending space for conductors through awall opposite terminals in mm(inches) Install approved fittings and/or strain <br /> Wires per terminal(pole) reliefs to the EAST,WEST and SOUTH side <br /> Wire size,AWG or 1 2 3 4orMore walls and complete wiring installation. <br /> kcmil (mm2 mm (inch) mm (inch) mm (inch) mm (inch) Populate the junction box using the <br /> 14-10 (2.1-5.3) Not Specified - - U$ appropriate wire connectors,terminal ..Attach lid using (4) #10 x 3/4" SS Hex head <br /> oom <br /> 8 (8.4) 38.1 (1-1/2) blocks,or other needed components. screws provided.Tighten until snug. <br /> 6 (13.3) 50.8 (2) - Intertek <br /> 5025824 <br /> EZfSOLAR PHONE:385-202-4150 1 WWW.LZS0bTPR0DU0TS.0 ersolarproducts.com I info@ersolarproducts.commaking solar simple. DRAWING NUMBER: <br /> SS <br />
The URL can be used to link to this page
Your browser does not support the video tag.