Laserfiche WebLink
EN PHASE m IQ8M and IQ8A Microinverters BLUE RAVEN <br /> SOLAR <br /> INPUT 1 1 1: 1: <br /> Commonly used module pairings' W 260-460 295-500 <br /> Module compatibility To meet compatibility,PV modules must be within the following maximum input DC voltage and maximum module I . <br /> Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator <br /> MPPT voltage range V 30-45 32-45 <br /> Operating range V 16-58 <br /> i <br /> Minimum/Maximum start voltage V 22/58 <br /> Maximum input DC voltage V 60 <br /> J <br /> _ t Maximum continuous input DC current A 12 <br /> ' Maximum input DC short-circuit current A 25 <br /> Maximum module I A 20 <br /> Overvoltage class DC port II <br /> DC port backfeed current mA 0 <br /> PV array configuration 1 x 1 ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit <br /> OUTPUT 1 1: A: <br /> Peak output power VA 330 366 <br /> Maximum continuous output power VA _ 325 349 <br /> 1 Q 8 M and 1 Q 8A Microinverters Nominal grid voltage(L-L) V 240,split-phase(L-L),180' <br /> Minimum and Maximum grid voltage2 V 211-264 <br /> Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- Maximum continuous output current A 1.35 1.45 <br /> defined microinverters with split-phase power conversion capability to convert DC Easy to install <br /> Lightweight and com act with plug- <br /> is Nominal frequency H= 60 <br /> power to AC power efficiently.The brain of the semiconductor-based microinverterp p 9- <br /> is our proprietary application-specific integrated circuit(ASIC),which enables and-play connectors Extended frequency range Hz 47-68 <br /> the microinverter too operate in rid-tied or off- rid modes.This chi Is built using Power line communication(PLC) AC short-circuit fault current over <br /> P 9 9 P� 9 between components Arms 2 <br /> advanced 55-nm technology with high-speed digital logic and has superfast Faster installation with simple two- three cycles <br /> response times to changing loads and grid events,alleviating constraints on battery wire cabling Maximum units per 20 A(L-L)branch 11 <br /> sizing for home energy systems. circuit' <br /> High productivity and reliability Total harmonic distortion % <5 <br /> Produce power even when the grid Overvoltage class AC port III <br /> Enphase is down <br /> More than one million cumulative AC port backfeed current mA 30 <br /> hours of testing <br /> ­25 Power factor setting 1.0 <br /> Class II double-insulated enclosure <br /> year limited Optimized for the latest high- Grid-tied power factor(adjustable) 0.85 leading...0.85 lagging <br /> L_ warranty powered PV modules Peak efficiency / 97.8 97.7 <br /> Part of the Enphase Energy System,IQ8 Series IQ8 Series Microinverters redefine reliability CEC weighted efficiency % 97.5 97 <br /> Microinverters integrate with the IQ Battery, standards with more than one million Microgrid-forming <br /> IQ Gateway,and the Enphase App monitoring and cumulative hours of power-on testing, Complies with the latest advanced Nighttime power consumption mw 21 22 <br /> analysis software. enabling an industry-leading limited warranty grid support** <br /> MECHANICAL DATA <br /> of up to 25 years. Remote automatic updates for the <br /> latest grid requirements Ambient temperature range -40°C to 60°C(-40°F to 140°F) <br /> Configurable to support a wide Relative humidity range 4%to 100%(condensing) <br /> range of grid profiles <br /> Meets CA Rule 21(LIL 1741-SA)and IEEE DC connector type Staubli MC4 <br /> 1547:2018(UL 1741-SB 3rd Ed.) Dimensions(H•W•D) 212 mm MY)•175 mm(6.9")•30.2 mm 0.2") <br /> NOTE: Weight 1.1 kg(2.43lbs) <br /> • IQ8 Microinverters cannot be mixed together with Cooling Natural convection-no fans <br /> Connect PV modules quickly and easily to the IQ8 Series Microinverters are UL Listed as previous generations of Enphase microinverters <br /> IQ8 Series Microinverters that have integrated PV rapid shutdown equipment and conform 0Q7 Series,IQ6 Series,and so on)in the same Approved for wet locations Yes <br /> MC4 connectors. with various regulations when installed system. <br /> according to the manufacturer's instructions. Pollution degree PD3 <br /> • IQ Gateway is required to change the default grid <br /> profile at the time of installation to meet the local Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure <br /> Authority Having Jurisdiction(AHJ)requirements. <br /> Environmental category/UV exposure rating NEMA Type 6/outdoor <br /> *Meets UL 1741 only when installed with IQ System Controller 2. <br /> **IQ8M and IQ8A support split-phase,240 V installations only. <br /> (1)No enforced DC/AC ratio. <br /> (2)Nominal voltage range can be extended beyond nominal if required by the utility. DRAWING NUMBER: <br /> (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8MA-MC4-DSH-00205-2.0-EN-US-2023-11-03 <br /> I08MA-MC4-DSH-00205-2.0-EN-US-2023-11-03 SS <br />