My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2938 COLBY AVE GOLDEN SMOKE HOUSE 2025-07-11
>
Address Records
>
COLBY AVE
>
2938
>
GOLDEN SMOKE HOUSE
>
2938 COLBY AVE GOLDEN SMOKE HOUSE 2025-07-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2025 10:40:52 AM
Creation date
10/30/2024 8:34:03 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2938
Tenant Name
GOLDEN SMOKE HOUSE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
z SPREAD-SPECTRUM DETECTO <br /> ^"" Programming each wireless device with a specific The 1183 Series is a reliable,ceiling-mount heat <br /> DMPwireless communication employs 900MHz communication test interval eliminates wasteful, sensor available in two versions. The 1183-135F <br /> frequency-hopping spread-spectrum to ensure repetitive signaling.By eliminating multiple rounds responds if the temperature exceeds 135°. <br /> clear and accurate signal transmissions without of repetitive signals,battery life is extended. The 1183-135R adds a rate-of-rise feature that <br /> interference in practically any environment. responds if the temperature increases by 15°F <br /> TWO-WAY COMMUNICATION' SIMPLE PROGRAMMINI per minute or more. <br /> DMP wireless receivers su ervise for No special equipment is needed to program the <br /> p 1184 CARBON MONOXIDE <br /> system!Assign wireless transmitters to zones or <br /> transmitters that go missing. With Two-Way outputs during panel programming with Remote Ct <br /> communication, each wireless transmitter LinkTM or from the keypad. The 1184 Carbon Monoxide Detector is the ideal <br /> communicates with the receiver using choice for difficult-to-wire locations,applications <br /> supervision messages. Each transmittercan be .�R WITH where room aesthetics are critical, or where <br /> programmed for no supervision ora 3,60,or240 SYNCHRONIZED SOUNDERF hazardous materials are present. <br /> minute window providing flexibility and allowing The Model 1164 smoke detector for residential or <br /> increased security for those applications that commercial applications includes synchronized The sensor provides an early alert of potentially <br /> require shorter supervision times. sounders so when more than one 1164 is installed harmful levels of carbon monoxide in residential <br /> on a system,the alarm cadence will synchronize. or commercial installations. In addition, it also <br /> When the receiver does not receive any Any fire zone tripped on the panel will cause the transmits trouble, tamper, and low-battery <br /> supervision messages from the transmitter for sounders to initiate. The 1164 also includes a messages to the panel. <br /> the programmed window of time,the receiver tamper switch that sends a trouble signal when <br /> reports the zone or output as missing to the the detector is removed from the mounting base. COMMERCIAL FIRE APPROVED <br /> panel and Central Station. Up to 572 units can be installed on one system. DEVICES FOR USE WITH THE <br /> The 1164NS with no sounder is also available for XR150/XR550 <br /> The on-board LED on all1100SeriesTransmitters „n, IIwII1,CpeAl Tonr•^wAITTco <br /> provides built-in survey capability to allow for applications with existing sounder/notification <br /> single-person installations, eliminating the devices. Model 1103 Universal Transmitter is typically <br /> requirement for an external survey kit. used in commercial fire or burglary door/window <br /> applications.It offers the same look and features <br /> as the 1101 transmitter, with the addition of a <br /> 470k end-of-line resistor and wall tamper switch. <br /> SPECIFIC <br /> Battery Life Expectancy 5 years U.S.Patent No.7,239,236 <br /> Dimensions <br /> Transmitter Case 3.3"L x 1.6"W x 0.9"H COMPATIBILITY <br /> Magnet Housing 1.5"L x 0.5"W x 0.7"H XTL+,XT,and XR Series Panels <br /> TOR SPECIFICATIONS FF <br /> Battery Life Expectancy 1 year Frequency Range 903-927 MHz <br /> Dimensions ACCESSORIES <br /> Detector 5.6'x 2.4" CR123-FIRE 3.OV Panasonic Lithium Battery(for commercial fire devices) <br /> Base 5.4"x 0.46" CI "I" <br /> 3-135R DETECTOR SPECIFICATIONS FCC Part 15 Registration ID CCKPC0104 _ <br /> Battery Life Expectancy 2 years IC Registration ID 5251A-PC0104 <br /> Dimensions N <br /> Detector 5.8"x 2.2" <br /> Heat Alarm Specifications For additional approval information,access www.dmp.com and select Compliance. J <br /> Rate-of-Rise 15°F/min>105°F i' <br /> Fixed 135°F±5°F <br /> Drift Compensation <br /> Adjustment 0.5%/ft.max <br /> 'R SPECIFICATIC m <br /> Battery Life Expectancy 2 years _ <br /> 0 <br /> Dimensions 5.8"x 2.2" E <br /> s — <br /> s = <br /> Q <br /> Intrusion • 2500 North Partnership Boulevard 800.641.4282 dmp.com <br /> Springfield,Missouri 65803-8877 Designed, Engineered&Manufactured <br /> in Springfield, Missouri <br />
The URL can be used to link to this page
Your browser does not support the video tag.