AI <br /> �IIF <br /> FU LL U FE CARE F/R410 Ash ay,Ste 8 <br /> 17nw Ash Way,Ste 8 <br /> Lynnwood,WA 98037 <br /> 425-290-9600 <br /> FPISEATTLE.COM <br /> AES RADO NSTALLAT OR Fol <br /> REPORTING ZONE FROM RADIO TYPICAL INSTALLATION DETAIL SHEET/NDEX NFPA <br /> SHEET # SHEET DESCRIPTION 000805173 <br /> FA 0.0 FIRE ALARM AES INSTALLATION ROY L CATS <br /> CENTRAL STATION REPORTING ZONES <br /> QpOTECTj <br /> ZONE # ZONE DESCRIPTION PROJECT DETAILSa In <br /> 1 GENERAL ALARM LL <br /> 2 SUPERVISORY 1. THE EXISTING TWO—STORY BUILDING IS FULLY—SPRINKLED AND HAS AN EXISTING CONVENTIONAL FIRE ALARM �'y NFPA �^ <br /> CONTROL PANEL(SILENT KNIGHT 5208 FIRE PANEL) LOCATED BY THE SPRINKLER SYSTEM IN THE STORAGE <br /> 3 TROUBLE Room. CFPS <br /> 2. A NEW UL LISTED WIRELESS RADIO COMMUNICATOR (7707-88—ULP) IS BEING INSTALLED, SIGNALS WILL BE #1473 <br /> TRANSMITTED BY ZONE TO THE UL LISTED SUPERVISING STATION. A 12VDC 12Ah BATTERY WILL BE <br /> INSTALLED IN THE NEW AES RADIO. <br /> Oc Oc 3. THE NEW AES RADIO WILL USE THE EXISTING FACPS DIALER TO SEND CONTACT ID AND ONBOARD RELAYS <br /> VICINITY MAP TO TRANSMIT THE FOLLOWING HARDWIRED SIGNALS TO THE CENTRAL SUPERVISING STATION: ZONE 1: FIRE <br /> O O O O O ALARM /WATERFLOW, ZONE 2: SUPERVISORY, AND ZONE 3: TROUBLE. u n <br /> = a <br /> Ti® O O O O O 4. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. W Z ao <br /> t--�. srAius mnMc— Z w <br /> 0 <br /> ~V W <br /> Providence 1 I ¢ W <br /> QRegional II coo PROJECT CONTACT INFO w m a y <br /> Medical Center ® a z o <br /> J 0 ¢E m <br /> © TRoLHE sue OWNER/TENANT FIRE ALARM CONTRACTOR tsi>u tmi <br /> O O FULL LIFE CARE FIRE PROTECTION INC o o <br /> 1980 112TH AVE NE, Ste 210 17410 ASH WAY, Ste 8 2 w rc a <br /> TF�mw TRTmw BELLEVUE, WA 98004 LYNNWOOD, WA 98037 mom. O <br /> © ® ® PHHONEINTACT 206M316.680 EILY ERTS PHONE CONTACT 425 290.600 DAVID MOWm I. G <br /> EMILY.ROBERTSOFULLLIFECARE.ORG DAVID®FPISEATTLE.COM f>a. rc a <br /> O 00000000 O m Igo, m <br /> 4- ZONES 1A"U' REVISION RECORD <br /> 4 Everett - S CODE INFO DATE DESCRIPTION <br /> maae0amaa cJ2 ,6 ,films <br /> FU11 Life Care Sf10flOrlllSh AUTHORITY HAVING JURISDICTION : CITY OF EVERETT <br /> County Adult Day FIRE CODE : INTERNATIONAL FIRE CODE, 2018 EDITION <br /> Health Center BUILDING USE AND OCCUPANCY : (B) — SPRINKLED <br /> _ 7STANDARDS: 2018 IBC/IFC, 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT STANDARDS <br /> oeo cATeo�pvAc CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> 12vl 2Ah REMOTE SUPERVISING STATION : SECURITAS, INC. <br /> BA ERY PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION, INC. <br /> PARCEL NUMBERS 00439168101500 <br /> EXISTING OCI IIONALFACP(SEENTKIUGHr 5208 FIRE PANEL) INSTALLATION NOTES <br /> AES-7707-88-LILP RADIO CONMJMCATOR <br /> TYPICALVMM AND INSTALLA.TIONDETAILS 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS—BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> SITE PLAN SEQUENCE OF OPERATIONS <br /> 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). DATE: 02/13/2024 <br /> SYSTEM OUTPUTS 5. THE SYSTEM WILL BE 100% PRE—TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND PROJECT NAME <br /> Required Fire Safety Control PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL <br /> Central SupervisingINSPECTION. <br /> Station roe <br /> Control Unit Annunciation ,� 6. THE AES RADIO REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE FACP SHALL <br /> ti �01 DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING DEDICATED POWER <br /> oc TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT SERVES THE FIRE <br /> HEWITT AVE o4. ,o m` me ®° ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT <br /> m cov y (NFPA72, SECTION 10.5.5.2). <br /> w �o W > C4 <br /> 00 <br /> o�c DEVICE INSTALLATION REQUIREMENTS Q Q rn <br /> y yJQ o yJ Se 20 a L) W Q <br /> 0 zr W Ye <br /> F�°g FIRE ALARM DEVICE INSTALLATION REQUIREMENTS J j <br /> ® OJ O <br /> A.ao Q O <br /> Ja O� O g 3 e NOT PERMITTED J IY LIJ <br /> CE O Q e= moD Zy BRACKEN eox ACT DIFFUSER <br /> SER HERE a• M W <br /> IF <br /> m D Ja Ja Ja!`t yJQ!G yam@ J m cRlo T/ ELI LL N Lu <br /> A G QQQ m /N11 W <br /> mm c c CeF CeE`m`� FA DEVICE CEILING DETECTOR SMOKE 4 <br /> 4 O V `ry `ry try L MINIMUM 3' <br /> {� AWAY FROM NOT PERMITTED 12" <br /> SYSTEM INPUTS B C D E F G H I HVAc DIFFUSERS HERE <br /> 1 Manual Fire Alarm Pull-Station ♦ ♦♦ 1 H SMOKE <br /> 2 Smoke&Heat Detectors ♦ ♦♦ 2 <br /> FACP a 3 wet Waterflow, ♦ ♦ ♦♦♦ 3 J SHEET TITLE <br /> A.HEIGHT 92"A.F.F <br /> 4 Unused ♦ ♦ ♦♦ 4 MIN HEIGHT 82"AYY ® i6d 3 <br /> rSPRINKLER OM = 5 Sprinkler Tamper/PIV ♦ ♦ 5 <br /> ALL STto 6 Unused ♦ ♦ 6 FIRE ALARM <br /> J7 Fire Alarm AC Power Failure ♦ ♦ 7O PROJECT DETAILS <br /> m 8 Fire Alarm System Low Battery ♦ ♦ 8 PULL <br /> -1 F] <br /> 9 Open Circuit ♦ ♦ 9 ^A"A.F.F <br /> Nfo Ground Fault ♦ ♦ 10 SHEET NUMBER <br /> A B C D E F G H K <br /> Not to Scale FA <br /> O.O <br />