My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-223 2024-11-13
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-223
>
3003 W CASINO RD BLDG 45-223 2024-11-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2024 8:11:05 AM
Creation date
10/30/2024 11:54:11 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-223
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REM POWER CABLE (SUPPLIED <br /> 6 5 3 4 WITH REM) LEGEND <br /> FACP BATTERY CALCULATIONS JUNCTION BOX 4S UNLESS NOTED OTHERWISE <br /> F1 STANDBY ALARM <br /> 'COMPONENTS QTY. CURRENT CURRENT OS PHOTOELECTRIC SMOKE DETECTOR <br /> AFC-100(FACE) 1 0.13000A 0.22000A <br /> UD-2000(DACT) 1 0.01600A 0.02300A Q MANUAL STATION, DOUBLE ACTING <br /> SLC DEVICES SUPERVISORY ALARM <br /> 3 3 4"C 2 14THHN,1 14G Z B F L1:03 ��� CURRENT cURRENT <br /> / - # # Q�� PADzoo-PD 2 0.o0030A o.0003oA o.000soA o.000soA ® STROBE ALARM <br /> TG-P E M N u �P� PADI OO-HD 0 0.00030A 0.00030A O OOo00A 0.0700A <br /> F L1:02 PAD-DUCT 0 0.00030A 0.00030A O.000OOA 0.00000A IRI�I <br /> FACP EVT-FA-45-223 TG-7FS FF�F PAD100-PSSA/PSDA 2 0.00020A o.00020A 0.00040A 0.00040A ®� AUDIBLE/VISUAL ALARM <br /> (BY FIRE ALARM VENDOR) "" 1 1 4 7 �a MONITORED BY TYCO AND PADIOO-RM 0 0.00024A o.00024A o.0000OA o.000oOA 8 FIRE ALARM PANEL <br /> R S S� SIGNAL SENT TO CENTRAL PAD100-MIM 1 0.00020A 0.00020A 0.00020A 0.00020A <br /> 3 BOEING FIRE DEPARTMENT PAD100-DIM o 0.00024A 0.00024A o.0000OA o.000oOA <br /> u:o4 P�Q STANDBY ALARM TELEPHONE PANEL <br /> T F CURRENT CURRENT <br /> NAC CRT 1(AUX PWR) 0.018A 0.11000A 0.01800A 0.11000A <br /> DC STC2 STC1 TRIP BAIT AC S S4 NAC CRT 2 0.00A 0.0740A 0.000OOA 0.2660A 0 ADT PANEL <br /> L1:01 - O.00A o.0000OA O.000OOA o.000oOA <br /> 1 2 82 3 4 506 ��3 1�02 G �� SLC ALARM LED o.00A 0.03600A O.000OOA 0.03600A FAC FIRE ALARM COMMUNICATOR <br /> � TOTAL 0.16520A 0.6562A <br /> BED MIM 1:05 ANAL G PHON LINE CELLULAR <br /> TOTAL STANDBY CURRENT DRAW= 0.1652 AMPS <br /> EDL(AS NEEDED) (OPR MART TG-7FS-A X STANDBY TIME 48 HOURS CONSTRUCTION NOTES <br /> STANDBY AMP HOUR TOTAL= 7.930 AH <br /> WP 45-223 FACP TOTAL ALARM CURRENT DRAW= 0.6562 AMPS PROVIDE CELLULAR DIALER, AND MOUNT ADJACENT TO <br /> NAC2 X ALARM TIME 0.167 HOURS THE BUILDING FACP. CONFIGURE DIALER TO PROVIDE <br /> 3/4"C - (1) PHONE CABLE, 110CD 30CD ALARM AMP HOUR TOTAL= 0.110 AH SOLE PATH COMPATIBLE WITH NIC TION. DIALER SERVICE.HALL BE <br /> (1) 2 CONDUCTOR FPL OR STANDBY AH + ALARM AH = 8.04 AH <br /> %DE-RATING FACTOR 1.20(209) <br /> APPROVED EQUAL-< ANALOG PHONE LINE <br /> SECONDARY) TOTAL AH REQUIRED= 9ss AH � PROVIDE (1) CONDUIT PENETRATION FOR PHONE AND <br /> MINIMUM BATTERY SIZE NEEDED: 10 AH FIRE ALARM CONNECTIONS. WIRE AS SHOWN. PROVIDE <br /> EVT-FA-45-223 *TWO SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY CODE,AS SHOWN. BATTERY SIZE PROVIDED: 1 12 AH ADDRESSABLE MODULE AS NECESSARY TO PROVIDE <br /> NOTe 0.167 EQUALS 10 MINUTES OF ALARM TIME GENERAL TROUBLE ALARM FROM CELLULAR DIALER TO <br /> IL BUILDING FACE. <br /> FIRE ALARM SYSTEM COMMUNICATIONS DETAIL 2VS34-PNL. B/18 � PROVIDE (1) CONDUIT PENETRATION FOR 24/12VDC <br /> SCALE: NONE E260 E506 FACP VOLTAGE DROP CALCULATION POWER AND EARTH GROUND FROM THE BUILDING FACP <br /> BUILDING FIRE ALARM SYSTEM RISER CIRCUIT SUPPLY ALARM OHMS NGT TOTAL LAST DEVICE VGLTAG ROWER SURREY. PROVIDE ROWER AND EXPANSION <br /> NAME VOLTAGE CURRENT WIRE TYPE 1000 F FEET RESISTANCE VOLTAGE DROP 7 MODULE AND WIRE AS SHOWN. MAINTAIN <br /> SCALE: NONE E`06 NAC1(AUX) 24 VDC 0.110 A #14AWG SOLID 2.52 10 0.0504 20.395 VDC 0.03% MANUFACTURER'S REQUIRED 1/4" SEPARATION <br /> NAC2 24 VDC o.074 A #14AWG SOLID 2.52 10 0.0504 20.396 VDC 0.02% BETWEEN POWER AND COMMUNICATION WIRING. <br /> N/A 24 VDC 0.000 A #14AWG SOLID 2.52 0 0 00.00 VDC 07 <br /> N/A 24 VDC 0.000 A #14AWG SOLID 2.52 0 0 00.00 VDC o% ® PROVIDE PHENOLIC LABEL, WHITE LETTERING, RED <br /> BACKGROUND, THAT READS: <br /> STEP 1: VERIFY SIGNAL STRENGTH AT PROPOSED LOCATION FOR CELLULAR COMMUNICATOR PANEL INDICATED ON "FIRE ALARM CELLULAR DIALER" <br /> DRAWINGS. IF ACCEPTABLE *SIGNAL STRENGTH IS ACQUIRED, SKIP TO STEP 5. SEQUENCE OF OPERATIONS <br /> STEP 2: IF ORIGINALLY PROPOSED LOCATION IS INADEQUATE, FIELD TEST *SIGNAL STRENGTH WITHIN A 20FT RADIUS PROVIDE CELL ANTENNA AND EVALUATE FIELD SIGNAL <br /> TO IDENTIFY LOCATION(S) SUITABLE FOR INSTALLATION OF REMOTE/EXTERNAL CELLULAR ANTENNA. OUTPUT FUNCTIONS STRENGTH IN ACCORDANCE WITH DETAIL 2. INSTALL <br /> IF IMPACTED COORDINATE THE FINAL ANTENNA LOCATION WITH BOEING AND SPACE USERS SYSTEM ADDITIONAL CONDUIT AND EXTENDED ANTENNA CABLE <br /> ( ) FOR IF NECESSARY TO REMOTE MOUNT ANTENNA IF COVERAGE <br /> APPROVAL PRIOR TO ROUGH-IN AND SKIP TO STEP 4. ANNUNCIATION& SYSTEM IS NOT SUITABLE AT FACP LOCATION. UPDATE BOM <br /> STEP 3: IF ACCEPTABLE *SIGNAL STRENGTH IS NOT ACHIEVED WITHIN 20FT OF ORIGINAL PROPOSED LOCATION FOR TRANSMISSION ACTIONS WITH SELECTED CABLE LENGTH AND PROVIDE REDLINES <br /> CELLULAR COMMUNICATOR PANEL, PROPOSE ALTERNATE LOCATION FOR CELLULAR PANEL. COORDINATE TO BOEING ENGINEER. <br /> WITH BOEING AND SPACE USERS FOR POTENTIAL LOCATIONS, PREFERABLY NEAR ORIGINAL LOCATION. © FOR REMOTE INSTALLATIONS PROVIDE PHENOLIC LABEL, <br /> STEP 4: LOCATE AND PROVIDE EXTERNAL CELLULAR ANTENNA, EXTERIOR MOUNTING BRACKET AND COAXIAL CABLE tt,� Vi � WHITE LETTERING, RED BACKGROUND, THAT READS: <br /> FROM CELLULAR COMMUNICATOR TO THE ANTENNA. THE ANTENNA AND PANEL SHOULD BE LOCATED hS <br /> WITHIN 20FT OF EACH OTHER. 0 ; "FIRE ALARM CELLULAR ANTENNA" <br /> STEP 5: PROVIDE 24VDC POWER, MONITORING CIRCUIT, AND TELEPHONE LINE TO CELLULAR COMMUNICATOR FROM Q 44/ INSIDE CELL ENCLOSURE POST COMMUNICATOR <br /> BUILDING FACE. Q 4 Q SETTINGS AND CELLUAR PHONE NUMBER. PROVIDE <br /> STEP 6: PROVIDE REQUIRED SET-UP, PROGRAMMING AND TESTING OF CELLULAR COMMUNICATOR EQUIPMENT PER Q Z 0= O� Z PRINTED ABEL, HANDWRITTEN INFORMATION IS NOT <br /> 0 ACCEPTABLE. PROVIDE SETTINGS AND CELLULAR <br /> THE MANUFACTURER'S INSTRUCTIONS. CELLULAR DIALER SHALL BE CONFIGURED AND INSTALLED AS A J btu �QQ /� <br /> SOLE PATH FOR FIRE COMMUNICATIONS. Q INFORMATION TO BOEING ENGINEER. <br /> Q <br /> 4 O �O� �=V �Q <br /> *ACCEPTABLE SIGNAL STRENGTH SHALL BE DETERMINED BY MANUFACTURERS SPECIFICATIONS AND LOCAL AHJ Q / �/� 0J <br /> ORDINANCES. O <br /> O� <br /> Q Jm <br /> CELLULAR COMMUNICATOR INSTALLATION SEQUENCE 2 Q 0 0 <br /> SCALE: NONE E260 E506 = O <br /> ICI CO SJW �`SJ to ��J to OO <br /> INPUT CONDITION <br /> C Q,��co T co Q��co <br /> STANDBY CONDITION(NORMAL) i i <br /> C POWER FAILURE i i i i <br /> 45-223 BUILDING SYSTEM FACP POINTS ANY CIRCUIT-OPEN,SHORT,GROUND i i i i BILL of MATERIALS <br /> SLC DEVICE MISSING i i i i ITEM CITY. PART NO. MANUFACTURER DESCRIPTION <br /> POINT NUMBER/ZONE BOEING DESCRIPTION FACP POINT - COMMENTS - GRID/SHEET LOC. Z'COMM.FAULT/TELGAURDTROUBLE i i i i 1 1 3992753 POTTER FIRE ALARM CONTROL PANEL <br /> 11:01 1 SMK @FACP FACE SMOKE DETECTOR - 1E260 12�BATTERY FAULT-LOW/HIGH VOLTAGE i i i i 2 1 3992769 POTTER UD-2000 DACT CARD <br /> L1:02 2 MAN PULL @ E1 DOOR EAST DOOR 1 MANUAL PULL STATION - 1E260 3 2 3992732 POTTER PAD100 6" BASE <br /> 11:03 3 MAN PULL @ E2 DOOR EAST DOOR 2 MANUAL PULL STATION - 1E260 FIRE ALARM PULL STATION i i i i 4 2 3992770 POTTER PAD200 PHOTO DETECTOR <br /> L1:04 4 SMK OFFICE OFFICE SMOKE DETECTOR - 1E260 ¢SMOKE DETECTOR i i i i 5 2 3992720 POTTER PAD100 PULL STATION <br /> L1:05 5 CELL DIALER FAULT CELL DIALER TROUBLE - 1E260 <HEATDETECTOR 6 1 3992700 POTTER PAD100 MICO INPUT MODULE <br /> w i i i i 7 2 SLA1104 POWERPATROL 12VDC 12 AH BATTERIES <br /> BUILDING FACP POINTS LIST " 8 1 BK-P2RL SYSTEM SENSOR HORN/STROBES <br /> k <br /> SCALE: NONE E506 9 1 BK-P2RK SYSTEM SENSOR WEATHER PROOF HORN/STROBES <br /> 10 1 TG-7FS-A TELGUARD ATT CELLULAR DIALER <br /> m 11 1 SSU00689 SPACEAGE FIRE ALARM STORAGE CABINET <br /> DRAWN DATE SUBTITLE FIRE ALARM SYSTEM DETAILS CURRENT REVISION SYMBOL A DATE 05.06.24 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY J. SHELDON 03.06.24 ^� <br /> NEW FIRE MONITORING PANEL REPLACEMENT W9063564 ABR MDK 05.18.23 Michael Regan,ET THIS DESIGN AND/OR CHECKED <br /> /f��� � � SPECIFICATION IS APPROVED M.REGAN 03.06.24 SHEET <br /> -ABOE//VG® �''°� E <br /> A SHOP DRAWINGS 33311362 AGOW/JS AGOW/KM 03.06.24 T "IPROVED BY DEPT. DATE K. MULLEN 2.22.24 E506 <br /> MCC Level IFire Al/ilarm CHECKED <br /> Technician ID:144327 APPROVED BUILDING 45-223 JOB N0. COMP NO. <br /> Expires:03101/2026 33311362 <br /> APPROVED MDK EVERETT, WA DWG N0. 45-223-E506 <br />
The URL can be used to link to this page
Your browser does not support the video tag.