Laserfiche WebLink
8.251.5276 <br /> GEOTEST I Oak <br /> Bellingham I Arlington Oak Harbor <br /> www.geotest-inc.com <br /> Combined Section <br /> Job: TerraPower Surface: Pit Floor <br /> Combined Section Section: Pit Floor <br /> -------------------------------------------------------------------------------------------------------------------------------------------- <br /> Measured FF: 50.20 <44.30 -56.11> Specified FF: N/A Min Local FF: N/A <br /> Measured FL: 73.62 <59.54 -87.70> Specified FL: N/A Min Local FL: N/A <br /> -------------------------------------------------------------------------------------------------------------------------------------------- <br /> Run Name FF FL Readings <br /> 1 N W 49.54 <66.55-32.54> 45.78 <74.46-17.11> 12 <br /> 2NW 50.92 <65.99-35.85> 70.00 <99.66-40.35> 17 <br /> 3NW 63.66 <82.50-44.81> 125.94 <179.29-72.60> 17 <br /> 4NW 72.53 <97.42-47.64> 80.73 <131.30-30.17> 12 <br /> 1 N E 55.43 <74.46-36.41> 72.30 <117.58-27.01> 12 <br /> 2N E 35.11 <45.51-24.72> 58.13 <82.75-33.51> 17 <br /> 3NE 47.88 <62.05-33.71> 87.09 <123.98-50.20> 17 <br /> 4N E 64.76 <86.98-42.53> 179.12 <291.31-66.93> 12 <br /> -------------------------------------------------------------------------------------------------------------------------------------------- <br /> 44 Z-Readings 116 Dipstick Readings <br /> An additional run was requested that was 1'4" east of the western edge of the 12" Pit Slab. See below data (not <br /> included in above measured FF/FL calculated values): <br /> Run Name FF FL Readings <br /> EXTN 46.14 <60.55-31.72> 103.01 <152.17-53.85> 15 <br /> Page 2 of 8 <br />