My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4828 DELAWARE AVE 2024-11-01
>
Address Records
>
DELAWARE AVE
>
4828
>
4828 DELAWARE AVE 2024-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2024 2:05:28 PM
Creation date
11/1/2024 2:04:25 PM
Metadata
Fields
Template:
Address Document
Street Name
DELAWARE AVE
Street Number
4828
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. /W <br /> Concrete Beam Design Report Page 1 <br /> Concrete Beam Design <br /> Job: 22-32313 Designed By: RDH,PE <br /> Beam ID: Stairwell Wall Checked By: <br /> Date: 1/5/2023 11:42:32 AM Program: Concrete Beam Design 4.1 <br /> Description:4.6'deep 6'long <br /> Code ACI(2011) Design Method Ultimate Strength <br /> Member Type One-Way Slab Cross Section Shape Rectangular <br /> Span Data: <br /> Main Span Length 6.670 Ft <br /> Left End Support Pinned Right End Support Pinned <br /> Left Support Width 8.000 In Right Support Width 8.000 In <br /> Left Haunch Start Location Not Present Right Haunch Start Location Not Present <br /> Cross Section Data: <br /> Total Depth at Mid-Span 8.000 In Top Width at Mid-Span 12.000 In <br /> Material Data: <br /> fc 2.500 K/In2 Flexural Reinforcing fy 40.000 K/In2 <br /> Concrete Density 144.000 Lb/Ft' Shear Reinforcing fvy 40.000 K/In2 <br /> Concrete Tensile Strength 0.420 Kiln' Stress Block,Beta - 0.850 <br /> Design Criteria:`,) $4 <br /> Bottom Cover to 3eettp 2.000 In Top Cover to$tiau . 2.000 In <br /> Total Load Deflection Limit L/240.00 Live Load Deflection Limit L/360.00 <br /> Allow Cuts in Tension Zone N Check Crack Control Provisions Y <br /> ECHO OF LOAD INPUT <br /> DEAD LOAD LIVE LOAD WIND LOAD EARTHQUAKE ROOF LOAD <br /> LOAD <br /> Check Deflection. Yes <br /> Main Span <br /> #1 Linear Load Begin: 0.000 K/Ft -0.253 K/Ft <br /> End: 0.000 K/Ft -0.253 K/Ft <br /> Distance to Begin: 0.000 Ft 0.000 Ft <br /> Distance to End. 0.000 Ft 6.670 Ft <br /> CRITICAL SHEARS& MOMENTS <br /> Load Combination Dead Load: 1.400 x Dead Load <br /> Load Combination#1: 1.200 x Dead Load+1.600 x L+0.500 x R <br /> Load Combination#2: 1.200 x Dead Load+1.000 x L+1.600 x R <br /> Load Combination#3: 1.200 x Dead Load+0.800 x W+1.600 x R <br /> Load Combination#4: 1.200 x Dead Load+1.000 x L+1.600 x W+0.500 x R <br /> DEAD LOAD LOAD COMB 1 LOAD COMB 2 LOAD COMB 3 LOAD COMB 4 <br /> Shear Left End• 0.000 K 1.350 K 0.844 K 0 000 K 0.844 K <br /> Moment Left End: 0.000 K-Ft 0.000 K-Ft 0.000 K-Ft 0.000 K-Ft 0 000 K-Ft <br /> Shear Right End: 0.000 K -1.350 K -0.844 K 0.000 K -0.844 K <br /> Moment Right End: 0.000 K-Ft 0.000 K-Ft 0.000 K-Ft 0.000 K-Ft 0.000 K-Ft <br /> Maximum Moment 2.251 K-Ft 1.407 K-Ft 1.407 K-Ft <br /> Located at:_ 3.335 Ft 3.335 Ft 3.335 Ft <br /> Max Deflection 0.000 In -0.008 In -0.008 In 0.000 In -0.008 In <br /> Located at: 0.000 Ft 3.335 Ft 3.335 Ft 0.000 Ft 3.335 Ft <br /> Dead Part: 0.000 In 0.000 In 0.000 In 0.000 In <br /> Inflection Points: 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft 0.000 Ft <br /> 6.670 Ft 6.670 Ft 6.670 Ft 6.670 Ft 6.670 Ft <br /> \dbs-solProject FilesConstructionADU - Job # 1/5/2023 11:92:32 AM <br /> 22-32313Oh1fs ADU 4.6-6 gr40.rtf <br />
The URL can be used to link to this page
Your browser does not support the video tag.