Laserfiche WebLink
Permit PW240 PROJECT IDENTIFICATION SYMBOLS ISSUED <br /> Morgan <br /> Site Address: 512 Morgan Rd <br /> Owner: Jin Ho Kim D A TE <br /> App.Date: 5/31/2024 <br /> Description: Driveway APPLICABLE CODES PARTITIONS <br /> ZONING CODE CITY OF EVERETT MUNICIPAL CODE PARTITIONS <br /> BUILDING CODE 2018 INTERNATIONAL BUILDING CODE W/STATE AMENDMENTS <br /> APPROVED FIRE CODE 2018 INTERNATIONAL FIRE CODE <br /> ENERGY CODE 2018 WASHINGTON STATE ENERGY CODE (NON-RATED PARTITION) EXISTING TO REMAIN <br /> j ! PUBLIC WORKS DEPARTMENT PLUMBING CODE 2018 UNIFORM PLUMBING CODE (SHOWN SHAED) MAY 09 <br /> i BY:TJorgenson MECHANICAL CODE 2018 INTERNATIONAL MECHANICAL CODE <br /> ELECTRICAL CODE 2018 NATIONAL ELECTRICAL CODE -------------------- 2024 <br /> DATE:06/03/2024 <br /> i ACCESSIBILITY CODE 2018 INTERNATIONAL BUILDING CODE,ICC A117.1-2003 (1-HOUR RATED PARTITION) <br /> i CITY OF EVERETT REVIEWED FOR PERMIT <br /> .% BUILDING ADDRESS: EXISTING TO BE DEMOLISHED <br /> 512 MORGAN RD <br /> ........................ <br /> ._ .._. ._._.._.._.._ _ <br /> ___._.._.._..___._.._.._.._..___._.._..____._.._.._.._.._.._.._.._.._.._.._.._.._.._.._..____.._.._..____.._.._..__ — <br /> _ _ <br /> APPROVED EVERETT,WA 3 __—_—_—_—_—_ SHOWN DASHED <br /> Office of community,Planning&Economic Development PARCEL ID: 003930393300009400 (2-HOUR RATED PARTITION) <br /> PLANNING DEPARTMENT ZONING: AIR CORRIDOR2(AC2) <br /> NAME: DGray LOT AREA: 10,454 SF NEW WALLS <br /> DATE: 06/03/2024 EXISTING HOUSE: 1,542 SF(I)+1,638 SF(B)=3,180 SF <br /> Extend driveway surface to MORGAN R D <br /> street edge PROPOSED HOUSE: 3,180 SF(REMODEL INTERIOR 1ST FLOOR) <br /> PROPOSED STORY: 1 7 <br /> P L 65, 14 w <br /> "`�- ��-------- GENERAL N 0 TE S ~ <br /> . -.---.-.._.._..___._.._..___._.._.._..---.._.._.._.._____._ <br /> 1. DO NOT SCALE THE DRAWINGS. Q <br /> a q I <br /> �e• v faeMwla� 2. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF W <br /> j <br /> .v I THE WORK. r^ <br /> v Y I 3. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY,AND WHAT IS REQUIRED BY v l <br /> ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL.THE CONTRACTOR SHALL > <br /> I COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT <br /> v a i DOCUMENTS.NOTIFY THE ARCHITECT FOR RESOLUTION OF ALL DISCREPANCIES I , I <br /> v j OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. I//I <br /> 4. DIMENSIONS ARE TO THE STRUCTURAL GRID OR TO FINISH SURFACES.UNLESS LJ_ <br /> t e t 'v Vp LEGAL DESCRIPTION OTHERWISE INDICATED. <br /> I t < I 5. DOORS AND CASED OPENNINGS INDICATED NEARBY WALL INTERSECTIONS. <br /> 444 I <br /> SHALL BE LOCATED SO THAT EDGE OF THE FINISH OPENING IS SIX INCHES FROM <br /> a. i BEVERLY HILLS DIV 5 BLK 000 D-00 - LOT 94 TGW THE FACE OF THE BEARBY WALL UNLESS OTHERWISE INDICATED.ALL OTHER <br /> W 5.03FT OF LOT 95 DOORS AND CASED OPENINGS SHALL BE CENTERED BETWEEN ADJACENT WALL <br /> WALL INTERSECTIONS. <br /> I <br /> 6. EXISTING GRID DIMENSIONS ARE TAKEN FROM EXISTING DOCUMENTS. <br /> CONTRACTOR TO VERIFY AND CONFIRM ACTUAL DIMENSIONS/CONDITIONS. <br /> NOTIFY ARCHITECT OF ACTUAL DIMENSIONS AND CONDITIONS PRIOR TO <br /> ! CONSTRUCTION. <br /> III <br /> I I <br /> f I <br /> 1 <br /> I <br /> EXISTING HOUSE <br /> SCOPE OF WORK PROJECT DIRECTION <br /> i <br /> i <br /> L1 J 1 INSTALL NON BEARING INTERIOR WALL, WOOD RAMP, DRIVEWA GRASS OWNER: JINHO KIM a_ <br /> I ADDRESS: 512 MORGAN RD nn <br /> EVERETT, WA 98023 Q O <br /> !' XISTING DECK o <br /> in <br /> ! 00 <br /> f � <br /> I ( inw Z <br /> I o Q Q <br /> i <br /> t 0 CD <br /> I n,- <br /> Ld <br /> i <br /> w <br /> I <br /> I O LLJ <br /> j <br /> _ LO > <br /> VICINITY MAP DRAWING INDEX N w <br /> Ln <br /> j A-1 SITE PLAN <br /> A-2 PROPOSED FLOOR PLAN <br /> 1 <br /> A-3 DETAILS <br /> I A DETAILS <br /> I <br /> PL 65. 14 <br /> i I <br /> i <br /> I <br /> i I <br /> Al SITE PLAN <br /> A-1 <br /> SCALE: 1'=10'—O" <br /> i <br /> PROJECT AREA <br />